Effects of high-intensity curing lights on microleakage under orthodontic bands

被引:1
|
作者
Uysal, Tancan [1 ]
Ramoglu, Sabri Ilhan [1 ]
Ulker, Mustafa [3 ]
Ertas, Huseyin [2 ]
机构
[1] Erciyes Univ, Fac Dent, Dept Orthodont, TR-38039 Kayseri, Turkey
[2] Erciyes Univ, Fac Dent, Dept Conservat Dent & Endodont, TR-38039 Kayseri, Turkey
[3] Selcuk Univ, Fac Dent, Dept Conservat Dent & Endodont, Konya, Turkey
关键词
CONVENTIONAL GLASS-IONOMER; SHEAR BOND STRENGTH; MODIFIED COMPOSITE; BRACKETS; ADHESIVE; CEMENTS; POLYMERIZATION; ENAMEL; CURE; RESTORATIONS;
D O I
10.1016/j.ajodo.2008.09.032
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Our objective was to compare the effects of 3 light-curing units (LCUs) (quartz-tungsten-halogen [QTH], light-emitting diode [LED], and plasma-arc curing [PAC]) on the microleakage patterns of a polyacid-modified composite (PAMC) for band cementation between the cement-enamel and the cement-band interfaces from the buccal, lingual, occlusal, and gingival margins. Methods: Sixty freshly extracted third molars were randomly divided into 3 groups of 20 teeth each. Microetched molar bands were cemented in all groups with the PAMC (Ultra Band-Lok, Reliance Orthodontic Products, Itasca, Ill) and cured for 30 seconds with the QTH (Hilux 350, Express Dental Products, Toronto, Ontario, Canada), for 20 seconds with the LED (Elipar Freelight 2, 3M Espe, Seefeld, Germany), or for 6 seconds with the PAC (Power-Pac, American Medical Technologies, Hannover, Germany). A dye penetration method was used for microleakage evaluation. Microleakage was determined with a stereomicroscope for the cement-band and cement-enamel interfaces from the buccal and lingual sides at the occlusal and gingival margins. Statistical analyses were performed with the Kruskal-Wallis and Mann-Whitney U tests. The level of significance was set at P<0.05. Results: The gingival sides in the LED and PAC groups had higher microleakage scores compared with those observed on the occlusal sides at both the cement-band and cement-enamel interfaces. The buccal sides had similar microleakage values compared with those on the lingual sides for the cement-enamel and cement-band interfaces in all LCU types. Statistical comparisons showed that there were statistically significant differences among the investigated LCUs at the cement-enamel interface (P<0.05). Post hoc comparisons showed statistically significant microleakage differences between the PAC (median, 0.950 mm), the QTH (median, 0.383 mm) (P<0.01), and the PAC and the LED (median, 0.558 mm) (P<0.05) LCUs at the cement-enamel interfaces. Conclusions: The high-intensity curing device PAC is associated with more microleakage than the LED and QTH at the cement-enamel interface. (Am J Orthod Dentofacial Orthop 2010; 138: 201-7)
引用
收藏
页码:201 / 207
页数:7
相关论文
共 50 条
  • [1] Microleakage under Orthodontic Brackets Using High-intensity Curing Lights
    Ulker, Mustafa
    Uysal, Tancan
    Ramoglu, Sabri Ilhan
    Ertas, Huseyin
    ANGLE ORTHODONTIST, 2009, 79 (01) : 144 - 149
  • [2] Effects of High-intensity Curing Lights on Microleakage under Bonded Lingual Retainers
    Baysal, Asli
    Uysal, Tancan
    Ulker, Mustafa
    Usumez, Serdar
    ANGLE ORTHODONTIST, 2008, 78 (06) : 1084 - 1088
  • [3] Polymerization of orthodontic adhesives using modern high-intensity visible curing lights
    Kauppi, MR
    Combe, EC
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2003, 124 (03) : 316 - 322
  • [4] Clinical effect of reducing curing times with high-intensity LED lights
    Ward, Justin D.
    Wolf, Bethany J.
    Leite, Luis P.
    Zhou, Jing
    ANGLE ORTHODONTIST, 2015, 85 (06) : 1064 - 1069
  • [5] Effect of high-intensity curing lights on the polymerization of bulk-fill composites
    Daugherty, Mindy M.
    Lien, Wen
    Mansell, Michael R.
    Risk, Douglas L.
    Sauett, Daniel A.
    Vandewalle, Kraig S.
    DENTAL MATERIALS, 2018, 34 (10) : 1531 - 1541
  • [6] HIGH-INTENSITY LIGHTS STAY ON
    CRAIG, AM
    BUSINESS AND COMMERCIAL AVIATION, 1984, 54 (01): : 21 - 21
  • [7] A MODEL FOR RENDERING HIGH-INTENSITY LIGHTS
    ROKITA, P
    COMPUTERS & GRAPHICS, 1993, 17 (04) : 431 - 437
  • [8] Depth of cure and microleakagewith high-intensity and ramped resin-based composite curing lights
    Jain, P
    Pershing, A
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2003, 134 (09): : 1215 - 1223
  • [9] Curing efficiency and heat generation of various resin composites cured with high-intensity halogen lights
    Kleverlaan, CJ
    de Gee, AJ
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2004, 112 (01) : 84 - 88
  • [10] Effects of high-speed curing devices on shear bond strength and microleakage of orthodontic brackets
    James, JW
    Miller, BH
    English, JD
    Tadlock, LP
    Buschang, PH
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2003, 123 (05) : 555 - 561