Diagnostic and prognostic value of dobutamine thallium-201 single-photon emission computed tomography after heart transplantation

被引:44
|
作者
Wu, YW
Yen, RF
Lee, CM
Ho, YL
Chou, NK
Wang, SS
Huang, PJ
机构
[1] Natl Taiwan Univ Hosp, Dept Internal Med, Div Cardiol, Taipei 100, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Nucl Med, Taipei, Taiwan
[3] Natl Taiwan Univ Hosp, Dept Surg, Taipei, Taiwan
[4] Natl Taiwan Univ, Coll Med, Taipei, Taiwan
来源
关键词
D O I
10.1016/j.healun.2003.12.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Cardiac allograft vasculopathy (CAV) is a major cause of mortality in heart transplant recipients. We investigated the diagnostic and prognostic value of dobutamine thallium-201 ((TI)-T-201) single-photon emission computed tomography (SPECT) in heart transplant recipients. Methods: We studied 47 patients (age 51.6 +/- 11.7 years, 37 men), at a mean of 34.0 +/- 21.4 months after heart transplant, who received dobutamine (TI)-T-201 SPECTI, echocardiography and coronary angiography within 1 month of each other. SPECT was considered abnormal in the presence of reversible or fixed defects in >= 2 segments. Significant CAV was defined as >= 50% luminal stenosis. Results: Coronary angiograms were normal in 37 patients. Non-significant CAV was detected in 1 patient and significant CAV in 9 patients. The sensitivity, specificity, positive predictive value and negative predictive value of SPECT for the detection of significant angiographic CAV were 89%, 71%, 42% and 96%, respectively. Large reversible perfusion defects (>= 6 segments) always indicated significant CAV. In patients with normal left ventricular function, a lung/heart ratio (LHR) of >= 0-37 during stress was also an independent predictor of significant CAV (odds ratio 15.5, p = 0.04). A higher stress LHR was associated with greater vessel involvement (r = 0.516, p = 0.0002). Patients with impaired left ventricular function also had higher stress and resting LHR. Over 40.3 +/- 21.9 months after the first SPECT, 1 patient developed significant angiographic CAV and another 4 had cardiac death. Large reversible perfusion defect was a significant predictor of cardiac death (p = 0.002). Conclusions: Dobutamine (TI)-T-201 SPECT is a useful method for detecting patients with significant CAV and assessing prognosis. It is reasonable and safe to design individualized surveillance intensity of coronary angiography for post-transplant patients on the basis of non-invasive monitoring of dobutamine (TI)-T-201 testing. J Heart Lung Transplant 2005;24:544-50. Copyright (c) 2005 by the International Society for Heart and Lung Transplantation.
引用
收藏
页码:544 / 550
页数:7
相关论文
共 50 条
  • [1] Thallium-201 single-photon emission computed tomography in the detection of retroperitoneal schwannoma
    Nakahara, T
    Fujii, H
    Hashimoto, J
    Yabe, H
    Morioka, H
    Kubo, A
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (913): : 57 - 59
  • [2] The Dobutamine Stress Test With Thallium-201 Single-Photon Emission Computed Tomography and Radionuclide Angiography: Postinfarction Study
    Coma-Canella, Isabel
    Gomez Martinez, Maria del Val
    Rodrigo, Francisco
    Castro Beiras, Jose Manuel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (02) : 399 - 406
  • [3] Systematic review of the diagnostic accuracy of thallium-201 single-photon emission computed tomography in the detection of recurrent glioma
    Vos, M
    Tony, B
    Hoekstra, O
    Postma, T
    Heimans, J
    Hooft, L
    NEURO-ONCOLOGY, 2005, 7 (03) : 396 - 396
  • [4] Thallium-201 single-photon emission computed tomography as an early predictor of outcome in recurrent glioma
    Vos, MJ
    Hoekstra, OS
    Barkhof, F
    Berkhof, J
    Heimans, JJ
    van Groeningen, CJ
    Vandertop, WP
    Slotman, BJ
    Postma, TJ
    JOURNAL OF CLINICAL ONCOLOGY, 2003, 21 (19) : 3559 - 3565
  • [5] Improved diagnostic accuracy of thallium-201 myocardial perfusion single-photon emission computed tomography with CT attenuation correction
    Huang, Jei-Yie
    Yen, Ruoh-Fang
    Lee, Wen-Chung
    Huang, Chun-Kai
    Hsu, Pei-Ying
    Cheng, Mei-Fang
    Lu, Ching-Chu
    Lin, Yen-Hung
    Chien, Kuo-Liong
    Wu, Yen-Wen
    JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (05) : 1584 - 1595
  • [6] Improved diagnostic accuracy of thallium-201 myocardial perfusion single-photon emission computed tomography with CT attenuation correction
    Jei-Yie Huang
    Ruoh-Fang Yen
    Wen-Chung Lee
    Chun-Kai Huang
    Pei-Ying Hsu
    Mei-Fang Cheng
    Ching-Chu Lu
    Yen-Hung Lin
    Kuo-Liong Chien
    Yen-Wen Wu
    Journal of Nuclear Cardiology, 2019, 26 : 1584 - 1595
  • [7] Comparative value of dobutamine stress thallium-201 single photon emission computed tomography and echocardiography in the diagnosis of cardiac allograft arteriopathy
    Lakkis, NM
    Nagueh, SF
    He, ZX
    Mahmarian, JJ
    Verani, MS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 99150 - 99150
  • [8] Prognostic value of ECG-gated thallium-201 single-photon emission tomography in patients with coronary artery disease
    Matsuo, S
    Matsumoto, T
    Nakae, I
    Koh, T
    Masuda, D
    Takada, M
    Murata, K
    Horie, M
    ANNALS OF NUCLEAR MEDICINE, 2004, 18 (07) : 617 - 622
  • [9] Prognostic value of ECG-gated thallium-201 single-photon emission tomography in patients with coronary artery disease
    Shinro Matsuo
    Tetsuya Matsumoto
    Ichiro Nakae
    Terue Koh
    Daisuke Masuda
    Masahiko Takada
    Kiyoshi Murata
    Minoru Horie
    Annals of Nuclear Medicine, 2004, 18 : 617 - 622
  • [10] Detection of bladder cancer using single-photon emission computed tomography of thallium-201: A preliminary report
    Yang, CC
    Shiau, YC
    Sun, SS
    Kao, CH
    ANTICANCER RESEARCH, 2003, 23 (3C) : 2977 - 2980