Separating divertor closure effects on divertor detachment and pedestal shape in DIII-D

被引:32
|
作者
Moser, A. L. [1 ]
Casali, L. [1 ]
Covele, B. M. [1 ]
Leonard, A. W. [1 ]
McLean, A. G. [2 ]
Shafer, M. W. [3 ]
Wang, H. Q. [1 ]
Watkins, J. G. [4 ]
机构
[1] Gen Atom, San Diego, CA 92186 USA
[2] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[3] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
[4] Sandia Natl Labs, Albuquerque, NM 87185 USA
关键词
SCRAPE-OFF LAYER; PLASMA PARAMETERS; GEOMETRY; OPERATION; DENSITY; ONSET; WIDTH;
D O I
10.1063/1.5109027
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
Comparison between an open divertor and a more-closed divertor in DIII-D demonstrates detachment up to 40% lower pedestal density (ne;ped) in the closed divertor due to a combination of decreased fueling of the pedestal and increased dissipation in the scrape off layer (SOL) in the closed divertor, both resulting from increased neutral trapping in the divertor. Predicting whether the relationship between divertor closure and detachment will hold for an opaque SOL, in which the contribution of ionizing neutrals to fueling the pedestal is lessened, requires separating out different mechanisms contributing to the density difference at detachment. A series of experiments on DIII-D characterizes matched discharges using various divertor configurations to isolate the effects of divertor closure. These experiments show detachment up to 25% lower ne; sep in the closed divertor than in the open divertor, supported by simulations showing increased neutral trapping, and hence, increased dissipation, in the closed divertor. A difference in ne;ped=ne; sep is also seen: for matched ne;sep, the closed divertor has up to 20% lower ne;ped, consistent with modeling showing a smaller ionization fraction inside the separatrix in this case. Understanding how these pieces fit together will help in the development of predictive models of pedestal density and detached divertors compatible with a high performance core.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Study on divertor detachment and pedestal characteristics in the DIII-D upper closed divertor
    Wang, H. Q.
    Thomas, D. M.
    Leonard, A. W.
    Ma, X. X.
    Guo, H. Y.
    Moser, A. L.
    Watkins, J. G.
    Scotti, F.
    Lasnier, C.
    Fenstermacher, M. E.
    McLean, A. G.
    Shafer, M. W.
    Grierson, B.
    Ren, J.
    Osborne, T. H.
    [J]. NUCLEAR FUSION, 2023, 63 (04)
  • [2] The effect of divertor closure on detachment onset in DIII-D
    Moser, A. L.
    Leonard, A. W.
    McLean, A. G.
    Wang, H. Q.
    Watkins, J. G.
    [J]. NUCLEAR MATERIALS AND ENERGY, 2019, 19 : 67 - 71
  • [3] Modelling the effect of divertor closure on detachment onset in DIII-D with the SOLPS code
    Casali, L.
    Sang, C.
    Moser, A. L.
    Covele, B. M.
    Guo, H. Y.
    Samuell, C.
    [J]. CONTRIBUTIONS TO PLASMA PHYSICS, 2018, 58 (6-8) : 725 - 731
  • [4] Effect of divertor geometry on plasma detachment in DIII-D
    Wolf, NS
    Porter, GD
    Hill, DN
    Allen, SL
    [J]. JOURNAL OF NUCLEAR MATERIALS, 1999, 266 : 739 - 741
  • [5] Modeling of combined effects of divertor closure and advanced magnetic configuration on detachment in DIII-D by SOLPS
    Si, H.
    Guo, H. Y.
    Covele, B.
    Leonard, A. W.
    Watkins, J. G.
    Thomas, D.
    Ding, R.
    [J]. NUCLEAR FUSION, 2018, 58 (05)
  • [6] Effects of divertor electrical drifts on particle distribution and detachment near the divertor target plate in DIII-D
    Wang, H. Q.
    Watkins, J. G.
    Guo, H. Y.
    Groth, M.
    Jarvinen, A. E.
    Leonard, A. W.
    Ren, J.
    Thomas, D. M.
    Boedo, J.
    [J]. PHYSICS OF PLASMAS, 2021, 28 (05)
  • [7] Divertor erosion in DIII-D
    Whyte, DG
    Bastasz, R
    Brooks, JN
    Wampler, WR
    West, WP
    Wong, CPC
    Buzhinskij, OI
    Opimach, IV
    [J]. JOURNAL OF NUCLEAR MATERIALS, 1999, 266 : 67 - 74
  • [8] Compatibility of separatrix density scaling for divertor detachment with H-mode pedestal operation in DIII-D
    Leonard, A. W.
    McLean, A. G.
    Makowski, M. A.
    Stangeby, P. C.
    [J]. NUCLEAR FUSION, 2017, 57 (08)
  • [9] An evaluation of kinetic effects in the DIII-D divertor
    Watkins, JG
    Batishchev, O
    Boedo, J
    Hill, DN
    Lasnier, CJ
    Lehmer, R
    Leonard, AW
    Moyer, RA
    [J]. JOURNAL OF NUCLEAR MATERIALS, 1999, 266 : 980 - 985
  • [10] Calorimeter probe for the DIII-D divertor
    Watkins, JG
    Lasnier, CJ
    Whyte, DG
    Stangeby, PC
    Ulrickson, MA
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03): : 1574 - 1577