Wake respirometry allows breath-by-breath assessment of ventilation and CO2 production in unrestrained animals

被引:0
|
作者
Rose, Kayleigh A. R. [1 ]
Wilson, Rory P. [1 ]
Ramenda, Claudia [2 ]
Robotka, Hermina [2 ]
Wikelski, Martin [3 ,4 ]
Shepard, Emily L. C. [1 ,3 ]
机构
[1] Swansea Univ, Biosci, Singleton Pk, Swansea, Wales
[2] Max Planck Inst Anim Behav, Radolfzell am Bodensee, Germany
[3] Max Planck Inst Anim Behav, Radolfzell am Bodensee, Germany
[4] Univ Konstanz, Ctr Adv Study Collect Behav, Constance, Germany
基金
欧洲研究理事会;
关键词
DOUBLY LABELED WATER; DAILY ENERGY-EXPENDITURE; OXYGEN-CONSUMPTION; HEART-RATE; PHYSIOLOGICAL-PARAMETERS; RESPIRATORY VARIABLES; BODY ACCELERATION; FORAGING BEHAVIOR; METABOLIC POWER; HANDLING STRESS;
D O I
10.1016/j.isci.2022.104878
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Quantifying stress and energetic responses in animals are major challenges, as existing methods lack temporal resolution and elevate animal stress. We propose "wake respirometry," a new method of quantifying fine-scale changes in CO2 production in unrestrained animals, using a nondispersive infrared CO2 sensor positioned downwind of the animal, i.e., in its wake. We parameterize the dispersion of CO2 in wakes using known CO2 flow rates and wind speeds. Tests with three bird species in a wind tunnel demonstrated that the system can resolve breath-by-breath changes in CO2 concentration, with clear exhalation signatures increasing in period and integral with body size. Changes in physiological state were detectable following handling, flight, and exposure to a perceived threat. We discuss the potential of wake respirometry to quantify stress and respiratory patterns in wild animals and provide suggestions for estimating behavior-specific metabolic rates via full integration of CO2 production across the wake.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] ANALYSES OF BREATH-BY-BREATH RESPONSES OF VENTILATION TO CO2 EMPLOYING V-PCO2 LOOPS
    KAO, FF
    BABICH, AM
    MEI, SS
    WANG, C
    ACTA NEUROBIOLOGIAE EXPERIMENTALIS, 1973, 33 (01) : 163 - 175
  • [2] BREATH-BY-BREATH CO2 ELIMINATION BY ANALOG COMPUTER TECHNIQUES
    LIPSKY, JA
    ANGELONE, A
    MEDICAL RESEARCH ENGINEERING, 1967, 6 (03) : 11 - &
  • [3] BREATH-BY-BREATH EFFECTS OF IMPOSED ALTERNATE-BREATH OSCILLATIONS OF ALVEOLAR CO2
    MARSH, RHK
    LYEN, KR
    MCPHERSON, GA
    PEARSON, SB
    CUNNINGHAM, DJ
    RESPIRATION PHYSIOLOGY, 1973, 18 (01): : 80 - 91
  • [4] STEADY STATE CO2 ELIMINATION AS DETERMINED BY BREATH-BY-BREATH ANALOG TECHNIQUES
    LIPSKY, JA
    HARDINBR.J
    FEDERATION PROCEEDINGS, 1967, 26 (02) : 441 - &
  • [5] PULSED TITRATION SENSORS .1. A BREATH-BY-BREATH CO2 SENSOR
    ALBERY, WJ
    CLARK, D
    DRUMMOND, HJJ
    COOMBS, AJM
    YOUNG, WK
    HAHN, CEW
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 340 (1-2): : 99 - 110
  • [6] Decreased breath-by-breath variability of expired CO2 volume in infants with bronchopulmonary dysplasia
    Hacki, Christoph
    Fouzas, Sotirios
    Proietti, Elena
    Schulzke, Sven
    Latzin, Philipp
    Frey, Urs
    Delgado-Eckert, Edgar
    SWISS MEDICAL WEEKLY, 2013, 143 : 37S - 37S
  • [7] Field trials of a prototype ambulatory breath-by-breath CO2 monitor used by athletes
    Pearson, JS
    Stratton, E
    Roberts, A
    Varley, JS
    Cotterrell, D
    JOURNAL OF PHYSIOLOGY-LONDON, 1996, 491P : P3 - P3
  • [8] EVALUATION OF 4 METHODS FOR ESTIMATING BREATH-BY-BREATH EXCHANGE OF O-2 AND CO2
    GOLDMAN, E
    DZWONCZYK, R
    YADAGANI, V
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (05) : 524 - 526
  • [9] ADAPTIVE BUFFERING OF BREATH-BY-BREATH VARIATIONS OF END-TIDAL CO2 OF HUMANS
    MODARRESZADEH, M
    KUMP, KS
    CHIZECK, HJ
    HUDGEL, DW
    BRUCE, EN
    JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (05) : 2003 - 2012
  • [10] BREATH-BY-BREATH ASSESSMENT OF FLOW, VOLUME AND TIMING OF BREATHING DURING CO2 REBREATHING AND STEADY-STATE ELEVATED CO2 IN MAN
    HIRSCH, JA
    BISHOP, B
    FEDERATION PROCEEDINGS, 1980, 39 (03) : 1075 - 1075