Review of first clinical experiences with a 1.5 Tesla ceiling-mounted moveable intraoperative MRI system in Europe

被引:8
|
作者
Feigl, Guenther C. [1 ]
Heckl, Stefan [2 ]
Kullmann, Marcel [1 ]
Filip, Zoltan [3 ]
Decker, Karlheinz [3 ]
Klein, Jan [4 ]
Ernemann, Ulrike [2 ]
Tatagiba, Marcos [1 ]
Velnar, Tomaz [5 ,6 ]
Ritz, Rainer [1 ]
机构
[1] Univ Tubingen, Med Ctr, Dept Neurosurg, Hoppe Seyler Str 3, D-72074 Tubingen, Germany
[2] Univ Tubingen, Dept Neuroradiol, Med Ctr, Tubingen, Germany
[3] Univ Tubingen, Dept Anesthesiol, Med Ctr, Tubingen, Germany
[4] Fraunhofer MEVIS Bremen, Inst Med Image Comp, Bremen, Germany
[5] Univ Med Ctr Ljubljana, Dept Neurosurg, Ljubljana, Slovenia
[6] AMEU ECM Maribor, Maribor, Slovenia
关键词
Intraoperative MRI; mobile MRI; brain tumors; neuronavigation; moveable intraoperative MRI system; iMRI; GLIOMA SURGERY; 5-AMINOLEVULINIC ACID; MALIGNANT GLIOMA; IMAGING GUIDANCE; IMPLEMENTATION; RESECTION; SURVIVAL; GLIOBLASTOMA;
D O I
10.17305/bjbms.2018.3777
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
High-field intraoperative MRI (iMRI) systems provide excellent imaging quality and are used for resection control and update of image guidance systems in a number of centers. A ceiling-mounted intraoperative MRI system has several advantages compared to a conventional iMRI system. In this article, we report on first clinical experience with using such a state-of-the-art, the 1.5T iMRI system, in Europe. A total of 50 consecutive patients with intracranial tumors and vascular lesions were operated in the iMRI unit. We analyzed the patients' data, surgery preparation times, intraoperative scans, surgical time, and radicality of tumor removal. Patients' mean age was 46 years (range 8 to 77 years) and the median surgical procedure time was 5 hours (range 1 to 11 hours). The lesions included 6 low-grade gliomas, 8 grade III astrocytomas, 10 glioblastomas, 7 metastases, 7 pituitary adenomas, 2 cavernomas, 2 lymphomas, 1 cortical dysplasia, 3 aneurysms, 1 arterio-venous malformation and 1 extracranial-intracranial bypass, 1 clival chordoma, and 1 Chiari malformation. In the surgical treatment of tumor lesions, intraoperative imaging depicted tumor remnant in 29.7% of the cases, which led to a change in the intraoperative strategy. The mobile 1.5T iMRI system proved to be safe and allowed an optimal workflow in the iMRI unit. Due to the fact that the MRI scanner is moved into the operating room only for imaging, the working environment is comparable to a regular operating room.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 10 条
  • [1] Utility of a moveable 1.5 Tesla intraoperative MR imaging system
    Kaibara, T
    Saunders, JK
    Sutherland, GR
    CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 1999, 26 (04) : 313 - 316
  • [2] Imaging of murine brain tumors using a 1.5 Tesla clinical MRI system
    van Furth, WR
    Laughlin, S
    Taylor, MD
    Salhia, B
    Mainprize, T
    Henkelman, M
    Cusimano, MD
    Ackerley, C
    Rutka, JT
    CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 2003, 30 (04) : 326 - 332
  • [3] Laser-induced interstitial thermotherapy of liver metastases in an interventional 0.5 tesla MRI system:: Technique and first clinical experiences
    Fiedler, VU
    Schwarzmaier, HJ
    Eickmeyer, F
    Müller, FP
    Schoepp, C
    Verreet, PR
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (05) : 729 - 737
  • [4] In Vivo Single Cell Detection of Tumor-Infiltrating Lymphocytes With a Clinical 1.5 Tesla MRI System
    Smirnov, Pierre
    Poirier-Quinot, Marie
    Wilhelm, Claire
    Lavergne, Elise
    Ginefri, Jean-Christophe
    Combadiere, Behazine
    Clement, Olivier
    Darrasse, Luc
    Gazeau, Florence
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) : 1292 - 1297
  • [5] Beginning of clinical treatment using the 1.5 Tesla MR-Linac system in Japan: a narrative review
    Takahashi, Noriyoshi
    Tanaka, Shohei
    Umezawa, Rei
    Yamamoto, Takaya
    Suzuki, Yu
    Kishida, Keita
    Omata, So
    Arai, Kazuhiro
    Katsuta, Yoshiyuki
    Kadoya, Noriyuki
    Jingu, Keiichi
    TRANSLATIONAL CANCER RESEARCH, 2024, 13 (02) : 1131 - 1138
  • [6] The cumulative effects and clinical safety of repeat magnetic resonance imaging on an MRI-conditional pacemaker system at 1.5 tesla
    Nguyen, Thuy D.
    Sandberg, Sarah A.
    Durrani, Amir K.
    Mitchell, Kevin W.
    Keith, Matthew D.
    Gleva, Marye J.
    Woodard, Pamela K.
    HEART RHYTHM O2, 2021, 2 (01): : 73 - 79
  • [7] Review of clinical studies and first clinical experiences with a commercially available cone-beam breast CT in Europe
    Wienbeck, Susanne
    Lotz, Joachim
    Fischer, Uwe
    CLINICAL IMAGING, 2017, 42 : 50 - 59
  • [8] Is there still a role for lesioning in functional neurosurgery? Preliminary Italian (and world-first) experience with a transcranial MRI-guided focused ultrasound surgery system operating at 1.5 Tesla
    Iacopino, Domenico G.
    Giugno, Antonella
    Maugeri, Rosario
    Gagliardo, Cesare
    Franzini, Angelo
    Catalano, Carlo
    Midiri, Massimo
    JOURNAL OF NEUROSURGICAL SCIENCES, 2017, 61 (06) : 681 - 683
  • [9] MRI-guided percutaneous radiofrequency ablation of neoplasms using a MR-compatible RF-system: First technical and clinical experiences
    Kettenbach, J
    Peer, K
    Grgurin, M
    Berger, J
    Hupfl, M
    Lammer, J
    RADIOLOGY, 2001, 221 : 626 - 626
  • [10] First intraoperative, shared-resource, ultrahigh-field 3-Tesla magnetic resonance imaging system and its application in low-grade glioma resection Clinical article
    Pamir, M. Necmettin
    Ozduman, Koray
    Dincer, Alp
    Yildiz, Erdem
    Peker, Selcuk
    Ozek, M. Memet
    JOURNAL OF NEUROSURGERY, 2010, 112 (01) : 57 - 69