The accuracy of 26 aged and three new lens measures was investigated. Instruments were applied to surfaces of known curvature employing the conventional, hand-held method as well as while rigged on an optical bench. In addition, using the latter method, a controlled amount of surface tilt was introduced. A large inter-instrument variation in accuracy was encountered. In general, hand-held lens measures were found to provide equally accurate measurements on convex and concave surfaces, with the exception of the -20 D surface, and inclinations from 0 degrees to 5 degrees did not result in erroneous measurements. Results for inclinations of 15 degrees became unreliable. The different usages of the instrument are discussed. (C) 1998 The College of Optometrists. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:299 / 307
页数:9
相关论文
共 50 条
  • [1] Accuracy of New Intraocular Lens Power Calculation Formulas: A Lens Thickness Study
    Taroni, Leonardo
    Hoffer, Kenneth J.
    Lupardi, Enrico
    Barboni, Piero
    Savini, Giacomo
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (03) : 202 - 206
  • [2] Diagnostic Accuracy Measures
    Eusebi, Paolo
    [J]. CEREBROVASCULAR DISEASES, 2013, 36 (04) : 267 - 272
  • [3] A Study on the Accuracy of Prediction in Recommendation System Based on Similarity Measures
    AL-Bakri, Nadia Fadhil
    Hashim, Soukaena Hassan
    [J]. BAGHDAD SCIENCE JOURNAL, 2019, 16 (01) : 263 - 269
  • [4] ACCURACY ANALYSIS FOR A LENS COMPENSATOR
    FINKELSHTEIN, EI
    [J]. MEASUREMENT TECHNIQUES USSR, 1984, 27 (03): : 195 - 197
  • [5] ACCURACY OF A PERSPECTIVE CONTROL LENS
    PHILLIPS, SJ
    KELLEY, DL
    PRASSAS, SG
    [J]. RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 1984, 55 (02) : 197 - 200
  • [6] LENS MEASURES EYE PRESSURE
    GOSCH, J
    [J]. ELECTRONICS-US, 1983, 56 (08): : 86 - +
  • [7] Improving the accuracy of a time lens
    Yurchenko, VB
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1997, 14 (11) : 2921 - 2924
  • [8] Paediatric intraocular lens implants: accuracy of lens power calculations
    M K O'Gallagher
    M A Lagan
    C P Mulholland
    M Parker
    G McGinnity
    E M McLoone
    [J]. Eye, 2016, 30 : 1215 - 1220
  • [9] Paediatric intraocular lens implants: accuracy of lens power calculations
    O'Gallagher, M. K.
    Lagan, M. A.
    Mulholland, C. P.
    Parker, M.
    McGinnity, G.
    McLoone, E. M.
    [J]. EYE, 2016, 30 (09) : 1215 - 1220
  • [10] Accuracy of lens power calculation and centration of an aspheric intraocular lens
    Becker, K. A.
    Holzer, M. P.
    Reuland, A. J.
    Auffarth, G. U.
    [J]. OPHTHALMOLOGE, 2006, 103 (10): : 873 - 876