Influence of acoustic power on parietal thermometry during extracorporeal high intensity focused ultrasound treatments

被引:0
|
作者
Lacoste, F [1 ]
Feuillu, B [1 ]
Schlosser, J [1 ]
Vallancien, G [1 ]
机构
[1] CHU Nancy Brabois, Dept Urol, F-54511 Vandoeuvre Nancy, France
关键词
high intensity focused ultrasound; acoustic power; parietal thermometry;
D O I
10.1117/12.304347
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objectives: Compare the muscular parietal heating during high intensity focused ultrasound (HIFU) at different acoustic power levels. Methods: 3 series of 100 acoustic pulses of same energy but variable power were applied in vivo on the muscular lumbar and abdominal walls in 4 pigs. The target volume was located 47 to 94 mm behind the skin. Two thermocouples were inserted into the muscular wall facing the focal point 10-15 mm and 25-30 mm from the skin. The position of the treatment head was the same for the 3 series of acoustic pulses. The temperatures in the muscular wall were recorded during the HIFU treatment. Results: The lumbar muscular wall heating were: at low acoustic power (53 to 67W) 1.5 to 4.0 degrees C, at medium acoustic power (532 to 654W) 2.3 to 6.5 degrees C and at high acoustic power (1895 to 2372W) 1.2 to 5.0 degrees C. The abdominal muscular wall heating were: at low acoustic power (128 to 163W) 0.5 to 6.5 degrees C, at medium acoustic power (451 to 574W) 2.7 to 8.4 degrees C and at high acoustic power (1213 and 1545W) 3.3 to 8.5 degrees C. Conclusion: During extracorporeal HIFU treatments, the muscular parietal heating is variable among individuals and increases with the acoustic power.
引用
收藏
页码:242 / 245
页数:4
相关论文
共 50 条
  • [1] The effect of physical parameters on estimating acoustic intensity in high intensity focused ultrasound field using infrared thermometry
    Shen, Guofeng (shenguofeng@sjtu.edu.cn); Yu, Ying (20060868@jxutcm.edu.cn), 1600, Science Press (45):
  • [2] Noninvasive Thermometry in High-Intensity Focused Ultrasound Ablation
    Zhou, Yufeng
    ULTRASOUND QUARTERLY, 2017, 33 (04) : 253 - 260
  • [3] 2D ultrasound thermometry during thermal ablation with high-intensity focused ultrasound
    Rohfritsch, Adrien
    Barrere, Victor
    Estienne, Laura
    Melodelima, David
    ULTRASONICS, 2024, 142
  • [4] The effect of acoustic absorber's physical parameters on estimating acoustic intensity in high intensity focused ultrasound field using infrared thermometry
    SHEN Guofeng
    YU Ying
    ZHANG Helin
    CHEN Cunlei
    WANG Canhua
    Chinese Journal of Acoustics, 2021, 40 (02) : 224 - 238
  • [6] Extracorporeal acute cardiac pacing by High Intensity Focused Ultrasound
    Livneh, Amit
    Kimmel, Eitan
    Kohut, Andrew R.
    Adam, Dan
    PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 2014, 115 (2-3): : 140 - 153
  • [7] Extracorporeal Acute Cardiac Pacing by High Intensity Focused Ultrasound
    Amit, Livneh
    Eitan, Kimmel
    Dan, Adam
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 930 - 933
  • [8] Acoustic power measurement of high intensity focused ultrasound in medicine based on radiation force
    Shou, Wende
    Huang, Xiaowei
    Duan, Shimei
    Xia, Rongmin
    Shi, Zhonglong
    Geng, Xiaoming
    Li, Faqi
    ULTRASONICS, 2006, 44 : E17 - E20
  • [9] Neurosurgical Applications of High-Intensity Focused Ultrasound with Magnetic Resonance Thermometry
    Colen, Rivka R.
    Sahnoune, Iman
    Weinberg, Jeffrey S.
    NEUROSURGERY CLINICS OF NORTH AMERICA, 2017, 28 (04) : 559 - +
  • [10] High-energy shockwaves and extracorporeal high-intensity focused ultrasound
    Madersbacher, S
    Marberger, M
    JOURNAL OF ENDOUROLOGY, 2003, 17 (08) : 667 - 672