Investigation of fast Monte Carlo dose calculation for CyberKnife SRS/SRT treatment planning

被引:6
|
作者
Ma, C.
Li, J.
Deng, J.
Fan, J.
机构
[1] Fox Chase Canc Ctr, Philadelphia, PA 19111 USA
[2] Yale New Haven Med Ctr, New Haven, CT 06504 USA
关键词
D O I
10.1118/1.2761510
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Advanced stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) treatments require accurate dose calculation for treatment planning especially for treatment sites involving heterogeneous patient anatomy. In this work, we have implemented a fast Monte Carlo dose calculation algorithm for SRS/SRT treatment planning with the CyberKnife® system. Methods and Materials: Our system employs a superposition Monte Carlo algorithm. Photon mean free paths and interaction types for different materials and energies as well as the tracks of secondary electrons are pre‐simulated using the EGS4 code system. Photon interaction forcing and splitting are applied to the source photons in a patient calculation and the pre‐simulated tracks are repeated with proper corrections based on the tissue density and electron stopping powers. Electron energy is deposited along the tracks and accumulated in every voxel of the simulation geometry. Scattered and bremsstrahlung photons are transported, after applying the Russian Roulette technique, in the same way as the primary photons. Dose calculations are compared with full Monte Carlo simulations and the CyberKnife treatment planning system (TPS) for lung and head & neck treatments. Results: Comparisons with full Monte Carlo simulations show excellent agreement (within 0.5%). Significant differences in the target dose are found between Monte Carlo simulations and the CyberKnife TPS for SRS lung treatment. The calculation time using our superposition Monte Carlo algorithm is reduced up to 62 times (46 times on average for 10 typical clinical cases) compared to full Monte Carlo simulations. Conclusions: SRS/SRT dose distributions calculated by simple dose algorithms may be significantly overestimated for small lung target volumes, which can be improved by accurate Monte Carlo dose calculations. Properly implemented fast Monte Carlo algorithms can improve dosimetric accuracy with little or no compromise to computational efficiency. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2589 / 2590
页数:2
相关论文
共 50 条
  • [1] Implementation of Monte Carlo Dose Calculation for CyberKnife treatment planning
    Ma, C-M
    Li, J. S.
    Deng, J.
    Fan, J.
    [J]. INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP, 2008, 102
  • [2] Is Monte Carlo Dose Calculation Method Necessary for Cyberknife Brain Treatment Planning?
    Wang, L.
    Fourkal, E.
    Hayes, S.
    Jin, L.
    Ma, C.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 275 - 275
  • [3] Commissioning fast Monte Carlo dose calculation for lung treatment planning
    Craig, J
    Wong, E
    Mulligan, M
    Gladwish, A
    Gaede, S
    Chen, J
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2113 - 2113
  • [4] Evaluation of the treatment planning system of the Cyberknife by means of a comparison to Monte Carlo calculation
    Cora, S
    Francescon, P
    Cavedon, C
    Avanzo, M
    Stancanello, J
    Scalchi, P
    Spezi, E
    Ferri, A
    Bergamini, C
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S96 - S96
  • [5] Inverse treatment planning for radiation therapy based on fast Monte Carlo dose calculation
    Fippel, M
    Alber, M
    Birkner, M
    Laub, W
    Nüsslin, F
    Kawrakow, I
    [J]. ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 217 - 222
  • [6] Commissioning a fast Monte Carlo dose calculation algorithm for lung cancer treatment planning
    Craig, Jeff
    Oliver, Mike
    Gladwish, Adam
    Mulligan, Matt
    Chen, Jeff
    Wong, Eugene
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (02): : 83 - 97
  • [7] Treatment Planning Accuracy of the CyberKnife Monte Carlo Algorithm Compared to Other Commercially Available Dose Calculation Algorithms
    Sharma, S. C.
    Ott, J.
    Williams, J.
    Dickow, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S771 - S772
  • [8] Implementation of Clinical Monte Carlo Dose Calculation for CyberKnife On a Web-Based Treatment Planning System WebTPS
    Zerouali, K.
    Renaud, M.
    DeBlois, F.
    Bouchard, H.
    Carrier, J.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [9] Investigation of Dosimetric Accuracy for CyberKnife Intracranial SRT/SRS Treatment Planning Using a Consistent CT Calibration Model
    Liu, J.
    Jin, L.
    Chen, X.
    Chen, L.
    Wang, L.
    Ma, C.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [10] Monte Carlo Dose Calculation for Clinical IMRT Treatment Planning
    Siebers, J.