Validation of hemoglobin and water molar absorption spectra in near-infrared diffuse optical tomography

被引:11
|
作者
Srinivasan, S [1 ]
Pogue, BW [1 ]
Jiang, SD [1 ]
Dehghani, H [1 ]
Paulsen, KD [1 ]
机构
[1] Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA
关键词
D O I
10.1117/12.478219
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Near Infrared diffuse optical tomography was used to measure the molar absorption spectra for deoxyhemoglobin, oxyhemoglobin and water through phantom experiments. The measured spectra compensate for any systemic errors and errors arising from model-based estimation of concentrations of these chromophores, and show reasonable agreement with existing literature values. The spectra were validated by phantom experiments to obtain the oxygen dissociation curve. Variation of the partial pressure of oxygen in solution yielded results consistent with theory with mean error of 7.6% in estimation of oxygen saturation, and accurate within 5% in estimation of hemoglobin.
引用
收藏
页码:407 / 415
页数:9
相关论文
共 50 条
  • [1] Near-infrared diffuse optical tomography
    Hielscher, AH
    Bluestone, AY
    Abdoulaev, GS
    Klose, AD
    Lasker, J
    Stewart, M
    Netz, U
    Beuthan, J
    [J]. DISEASE MARKERS, 2002, 18 (5-6) : 313 - 337
  • [2] NEAR-INFRARED OPTICAL-ABSORPTION SPECTRA OF PHOTODISSOCIATED HEMOGLOBIN AND MYOGLOBIN
    SASSAROLI, M
    ROUSSEAU, DL
    [J]. BIOPHYSICAL JOURNAL, 1986, 49 (02) : A537 - A537
  • [3] Hemoglobin imaging with hybrid magnetic resonance and near-infrared diffuse tomography
    Pogue, BW
    Zhu, HQ
    Nwaigwe, C
    McBride, TO
    Osterberg, UL
    Paulsen, KD
    Dunn, JF
    [J]. OXYGEN TRANSPORT TO TISSUE XXIV, 2003, 530 : 215 - 224
  • [4] Nonquadratic penalization improves near-infrared diffuse optical tomography
    Jagannath, Ravi Prasad K.
    Yalavarthy, Phaneendra K.
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2013, 30 (08) : 1516 - 1523
  • [5] Quantitative hemoglobin tomography with diffuse near-infrared spectroscopy: Pilot results in the breast
    Pogue, BW
    Poplack, SP
    McBride, TO
    Wells, WA
    Osterman, KS
    Osterberg, UL
    Paulsen, KD
    [J]. RADIOLOGY, 2001, 218 (01) : 261 - 266
  • [6] Metal nanoshells as a contrast agent in near-infrared diffuse optical tomography
    Wu, CF
    Liang, XP
    Jiang, HB
    [J]. OPTICS COMMUNICATIONS, 2005, 253 (1-3) : 214 - 221
  • [7] Improved quantification of small objects in near-infrared diffuse optical tomography
    Srinivasan, S
    Pogue, BW
    Dehghani, H
    Jiang, SD
    Song, XM
    Paulsen, KD
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (06) : 1161 - 1171
  • [8] Design and implementation of a multifrequency near-infrared diffuse optical tomography system
    Gulsen, G
    Xiong, B
    Birgul, O
    Nalcioglu, O
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (01)
  • [9] Instrumentation for video-rate near-infrared diffuse optical tomography
    Piao, D
    Dehghani, H
    Jiang, S
    Srinivasan, S
    Pogue, BW
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (12): : 1 - 13
  • [10] Simulation study on the inverse problem of diffuse optical tomography with near-infrared spectroscopy
    Shimokawa, Takeaki
    Kosaka, Takashi
    Yamashita, Okito
    Sato, Masaaki
    [J]. NEUROSCIENCE RESEARCH, 2010, 68 : E332 - E332