Comparison of the GDx VCC scanning laser polarimeter and the stratus optical coherence tomograph in the detection of band atrophy of the optic nerve

被引:16
|
作者
Monteiro, M. L. R. [1 ]
Moura, F. C. [1 ]
机构
[1] Univ Sao Paulo, Sch Med, Hosp Clin, BR-01227200 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
optical coherence tomography; scanning laser polarimeter; retinal nerve fibre layer; band atrophy;
D O I
10.1038/sj.eye.6702694
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim To compare the ability of scanning laser polarimeter (SLP) with variable corneal compensation (GDx VCC) and optical coherence tomograph (Stratus OCT) to discriminate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Methods The study included 37 eyes with BA and temporal visual field (VF) defects from chiasmal compression, and 29 normal eyes. Subjects underwent standard automated perimetry (SAP) and retinal nerve fibre layer (RNFL) scans using GDx VCC and Stratus OCT. The severity of the VF defects was evaluated by the temporal mean defect (TMD), calculated as the average of 22 values of the temporal total deviation plot on SAP. Receiver operating characteristic (ROC) curves were calculated. Pearson's correlation coefficients were used to evaluate the relationship between RNFL thickness parameters and the TMD. Results No significant difference was found between the ROC curves areas (AUCs) for the GDx VCC and Stratus OCT with regard to average RNFL thickness (0.98 and 0.99, respectively) and the superior (0.94; 0.95), inferior (0.96; 0.97), and nasal (0.92; 0.96) quadrants. However, the AUC in the temporal quadrant (0.77) was significantly smaller (P < 0.001) with GDx VCC than with Stratus OCT (0.98). Lower TMD values were associated with smaller RNFL thickness in most parameters from both equipments. Conclusion Adding VCC resulted in improved performance in SLP when evaluating eyes with BA, and both technologies are sensitive in detecting average, superior, inferior, and nasal quadrant RNFL loss. However, GDx VCC still poorly discriminates RNFL loss in the temporal quadrant when compared with Stratus OCT.
引用
收藏
页码:641 / 648
页数:8
相关论文
共 50 条
  • [1] Comparison of the GDx VCC scanning laser polarimeter and the stratus optical coherence tomograph in the detection of band atrophy of the optic nerve
    M L R Monteiro
    F C Moura
    [J]. Eye, 2008, 22 : 641 - 648
  • [2] Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma
    Medeiros, FA
    Zangwill, LM
    Bowd, C
    Weinreb, RN
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2004, 122 (06) : 827 - 837
  • [3] Comparison of retinal nerve fiber layer photography, GDx VCC scanning laser polarimeter, and stratus OCT3 optical coherence tomograph for detection of glaucoma
    Ha, S
    Lee, ES
    Seong, GJ
    Hong, YJ
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [4] Comparison of GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope and StratusOCT optical coherence tomograph for glaucoma detection
    Medeiros, FA
    Bowd, C
    Zangwill, LM
    Weinreb, RN
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U128 - U128
  • [5] Comparison between GDx VCC scanning laser polarimetry and Stratus OCT optical coherence tomography in the diagnosis of chronic glaucoma
    Brusini, Paolo
    Salvetat, Maria L.
    Zeppieri, Marco
    Tosoni, Claudia
    Parisi, Lucia
    Felletti, Mirella
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2006, 84 (05): : 650 - 655
  • [6] Retinal nerve fiber layer evaluation of spectral domain optical coherence tomograph and scanning laser polarimeter to diagnose glaucoma
    Rao, H. L.
    Yadav, R. K.
    Addepalli, U. K.
    Chaudhary, S.
    Senthil, S.
    Choudhari, N. S.
    Garudadri, C. S.
    [J]. EYE, 2014, 28 (06) : 654 - 661
  • [7] Retinal nerve fiber layer evaluation of spectral domain optical coherence tomograph and scanning laser polarimeter to diagnose glaucoma
    H L Rao
    R K Yadav
    U K Addepalli
    S Chaudhary
    S Senthil
    N S Choudhari
    C S Garudadri
    [J]. Eye, 2014, 28 : 654 - 661
  • [8] Comparison of Repeatability of Retinal Nerve Fiber Layer Thickness Measurement Made Using the RTVue Fourier-domain Optical Coherence Tomograph and the GDx Scanning Laser Polarimeter With Variable or Enhanced Corneal Compensation
    Garas, Anita
    Toth, Marta
    Vargha, Peter
    Hollo, Gabor
    [J]. JOURNAL OF GLAUCOMA, 2010, 19 (06) : 412 - 417
  • [9] Comparison of optical coherence tomography (OCT-3) and scanning laser polarimetry (GDx VCC) for detecting retinal nerve fibre layer thinning in multiple sclerosis
    Balcer, L.
    Zaveri, M.
    Conger, A.
    Frohman, T.
    Binkholder, B.
    Galetta, S.
    Markowitz, C.
    Jacobs, D.
    Cutter, G.
    Calabresi, R.
    Froliman, E.
    [J]. MULTIPLE SCLEROSIS, 2007, 13 : S32 - S32
  • [10] Diagnostic ability of the Heidelberg retina tomograph, optical coherence tomograph, and scanning laser polarimeter in open-angle glaucoma
    Pueyo, Victoria
    Polo, Vicente
    Larrosa, Jose Manuel
    Ferreras, Antonio
    Pablo, Luis Emilio
    Honrubia, Francisco Manuel
    [J]. JOURNAL OF GLAUCOMA, 2007, 16 (02) : 173 - 177