Quantitative evaluation of maxillary interradicular bone with cone-beam computed tomography for bicortical placement of orthodontic mini-implants

被引:24
|
作者
Yang, Lei [1 ]
Li, Feifei [1 ]
Cao, Meng [1 ]
Chen, Hong
Wang, Xi
Chen, Xuepeng [2 ]
Yang, Le
Gao, Weiran [3 ]
Petrone, Joseph F. [4 ]
Ding, Yin [1 ]
机构
[1] Fourth Mil Med Univ, State Key Lab Mil Stomatol, Dept Orthodont, Sch Stomatol, Xian 710032, Shaanxi, Peoples R China
[2] Zhejiang Univ, Hosp Stomatol, Dept Orthodont, Hangzhou 310003, Zhejiang, Peoples R China
[3] 264th Hosp Chinese Peoples Liberat Army, Taiyuan, Shanxi, Peoples R China
[4] Univ Pittsburgh, Sch Dent Med, Dept Orthodont & Dentofacial Orthoped, Pittsburgh, PA USA
基金
中国国家自然科学基金;
关键词
CANCELLOUS BONE; SCREW IMPLANTS; DENSITY; ANCHORAGE; THICKNESS; STRAIN; INTRUSION; STRENGTH; ALVEOLAR; STRESS;
D O I
10.1016/j.ajodo.2015.02.018
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to propose a protocol for safe bicortical placement of mini-implants by measuring the interradicular spaces of the maxillary teeth and the bone quality. Methods: Cone-beam computed tomography data were obtained from 50 adults. Three-dimensional reconstructions and measurements were made with SimplantPro software (Materialise, Leuven, Belgium). For each interradicular site, the bone thicknesses and interradicular distances at the planes 1.5, 3, 6, and 9 mm above the cementoenamel junction were measured. Standard bone units were defined to evaluate the influences of bone density and the different placement patterns on the stability of the mini-implants. Results: The safe interradicular sites in the maxilla for bicortical placement of 1.5-mm-diameter mini-implants were in all planes between the first and second premolars, and between the second premolar and the first molar. The safe palatal sites were between the first and second molars, and the safe labial sites of the 9-mm plane were between the central incisors, and between the lateral incisor and the canine. The safe buccal sites of the 6-and 9-mm planes were between the first and second molars, and the safe buccal sites of the 3-, 6-, and 9-mm planes were between the canine and the first premolar. Most bone thicknesses were from 8 to 12 mm. The optimal placement angle between the second premolar and the first molar was 58 degrees. Bicortical placement could have more standard bone units than unicortical placement in the maxilla. Conclusions: Bicortical placement would be more stable in the maxilla. For the site between the molars, special care should be taken at a plane higher than 6 mm to prevent maxillary sinus penetration. The most favorable interradicular area in the maxilla was between the second premolar and the first molar.
引用
收藏
页码:725 / 737
页数:13
相关论文
共 50 条
  • [1] Evaluation of interdental space of the maxillary posterior area for orthodontic mini-implants with cone-beam computed tomography
    Kim, Seong-Hun
    Yoon, Hyeong-Gun
    Choi, Yong-Suk
    Hwang, Eui-Hwan
    Kook, Yoon-Ah
    Nelson, Gerald
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 135 (05) : 635 - 641
  • [2] Root proximity and inclination of orthodontic mini-implants after placement: Cone-beam computed tomography evaluation
    Shinohara, Akihiko
    Motoyoshi, Mitsuru
    Uchida, Yasuki
    Shimizu, Noriyoshi
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 144 (01) : 50 - 56
  • [3] Assessment of available sites for palatal orthodontic mini-implants through cone-beam computed tomography
    Lyu, Xinwei
    Guo, Jiusi
    Chen, Liangrui
    Gao, Yi
    Liu, Lu
    Pu, Lingling
    Lai, Wenli
    Long, Hu
    [J]. ANGLE ORTHODONTIST, 2020, 90 (04) : 516 - 523
  • [4] Quantitative cone-beam computed tomography evaluation of palatal bone thickness for orthodontic miniscrew placement
    Gracco, Antonio
    Lombardo, Luca
    Cozzani, Mauro
    Siciliani, Giuseppe
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (03) : 361 - 369
  • [5] Surgical positioning of orthodontic mini-implants with guides fabricated on models replicated with cone-beam computed tomography
    Kim, Seong-Hun
    Choi, Yong-Suk
    Hwang, Eui-Hwan
    Chung, Kyu-Rhim
    Kook, Yoon-Ah
    Nelson, Gerald
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (04) : S82 - S89
  • [6] Cone-beam computed tomography evaluation of mini-implants after placement: Is root proximity a major risk factor for failure?
    Kim, Seong-Hun
    Kang, Seok-Man
    Choi, Yong-Suk
    Kook, Yoon-Ah
    Chung, Kyu-Rhim
    Huang, John C.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 138 (03) : 264 - 276
  • [7] Evaluation of Optimal Insertion Sites and Angles for Orthodontic Mini-Implants at the Anterior Nasal Spine Region Based on Cone-Beam Computed Tomography
    Lin, Donger
    Wen, Shangyou
    Ye, Zelin
    Yang, Yi
    Yuan, Xuechun
    Lai, Wenli
    You, Meng
    Long, Hu
    [J]. JOURNAL OF CLINICAL MEDICINE, 2024, 13 (03)
  • [8] Palatal bone thickness measured by palatal index method using cone-beam computed tomography in nonorthodontic patients for placement of mini-implants
    Manjula, W. S.
    Murali, R. V.
    Kumar, S. Kishore
    Tajir, Faizal
    Mahalakshmi, K.
    [J]. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2015, 7 (05): : S107 - S110
  • [9] Tomographic mapping of mandibular interradicular spaces for placement of orthodontic mini-implants
    Monnerat, Cristiane
    Restle, Luciana
    Mucha, Jose Nelson
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 135 (04) : 428.e1 - 428.e9
  • [10] Three-dimensional Evaluation of Interradicular Areas and Cortical Bone Thickness for Orthodontic Miniscrew Implant Placement Using Cone-beam Computed Tomography
    Dharmadeep, Garadappagari
    Naik, Moode Kaladhar
    Reddy, Yellampalli Muralidhar
    Cheruluri, Sreekanth
    Raj, Kranthi Praveen
    Reddy, Badepalli Reddeppa
    [J]. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2020, 12 : 99 - 104