Quantification of vaginal motion associated with daily endorectal balloon placement during whole pelvis radiotherapy for gynecologic cancers

被引:4
|
作者
Taku, Nicolette [1 ]
Dise, Joseph [1 ]
Kenton, Owen [1 ]
Yin, Lingshu [1 ]
Teo, Boon-Keng Kevin [1 ]
Lin, Lilie L. [1 ]
机构
[1] Univ Penn, Dept Radiat Oncol, Perelman Sch Med, Philadelphia, PA 19104 USA
关键词
Vaginal movement; Gynecologic cancer; External beam radiation; Endorectal balloon; Bladder filling; MODULATED RADIATION-THERAPY; DOSE-VOLUME HISTOGRAMS; PROSTATE-CANCER; CONFORMAL RADIOTHERAPY; IMMOBILIZATION DEVICE; CERVICAL-CANCER; RECTAL BALLOON; ORGAN MOTION; TARGET; ENDOMETRIAL;
D O I
10.1016/j.radonc.2016.05.005
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: To quantify intra-treatment vaginal motion in women treated with daily endorectal balloon (ERB) placement and external beam radiotherapy for gynecologic cancers. Materials and methods: Eighteen post-hysterectomy women with gynecologic cancers underwent computed tomography (CT) simulation scans and daily treatment with ERB. Fiducial markers were placed at the vaginal apex prior to simulation and patients were counseled on a pre-treatment bladder filling protocol. Weekly to biweekly verification CT scans were used to calculate the intra-treatment change in bladder volumes, rectal volumes, and fiducial coordinates along all axes. The planning target volume (PTV) margins required to encompass 95% of intra-treatment fiducial movement were calculated using the van Herk margin recipe. Results: The median bladder volume was 223 (range, 29-879) cc for verification CT scans. Mean intra-treatment fiducial displacements were 1.7 (range, 0-9.1) mm, 2.9 (range, 0-15.5) mm, and 2.5 (range, 0-11.8) mm along the left-right (L/R), superior-inferior (S/I), and anterior-posterior (A/P) axes, respectively. The van Herk PTV margins were 3 mm (L/R), 10 mm (S/I) and 7 mm (A/P). Conclusion: When compared to existing studies, the use of daily ERB with post-hysterectomy radiotherapy reduces vaginal motion along the A/P axis. The impact of variable bladder filling on vaginal motion is most evident along the S/I axis. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:532 / 536
页数:5
相关论文
共 11 条
  • [1] Quantifying Vaginal Motion Associated With Daily Endorectal Balloon During Whole Pelvis Radiation Therapy for Gynecologic Cancers
    Taku, N.
    Yin, L.
    Teo, B.
    Lin, L. L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S506 - S506
  • [2] An Endorectal Balloon Reduces Intrafraction Prostate Motion During Radiotherapy
    Smeenk, Robert Jan
    Louwe, Robert J. W.
    Langen, Katja M.
    Shah, Amish P.
    Kupelian, Patrick A.
    van Lin, Emile N. J. Th.
    Kaanders, Johannes H. A. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (02): : 661 - 669
  • [3] AN ENDORECTAL BALLOON REDUCES INTRAFRACTION PROSTATE MOTION DURING RADIOTHERAPY
    Smeenk, R. J.
    Louwe, R.
    Langen, K.
    Shah, A.
    Kupelian, P.
    van Lin, E.
    Kaanders, J.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S458 - S459
  • [4] REAL-TIME STUDY OF PROSTATE INTRAFRACTION MOTION DURING EXTERNAL BEAM RADIOTHERAPY WITH DAILY ENDORECTAL BALLOON
    Both, Stefan
    Wang, Ken Kang-Hsin
    Plastaras, John P.
    Deville, Curtiland
    Bar Ad, Voika
    Tochner, Zelig
    Vapiwala, Neha
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (05): : 1302 - 1309
  • [5] First Prospective Study to Determine the Role of Daily Endorectal Balloon on Prostate Intrafraction Motion Management during External Beam Radiotherapy
    Both, S.
    Wang, K.
    Plastaras, J.
    Deville, C.
    Bar Ad, V.
    Tochner, Z.
    Vapiwala, N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S669 - S669
  • [6] The impact of stool and gas volume on intrafraction prostate motion in patients undergoing radiotherapy with daily endorectal balloon
    Wang, Ken Kang-Hsin
    Vapiwala, Neha
    Viet Bui
    Deville, Curtiland
    Plastaras, John P.
    Bar-Ad, Voichita
    Tochner, Zelig
    Both, Stefan
    RADIOTHERAPY AND ONCOLOGY, 2014, 112 (01) : 89 - 94
  • [7] Is Prostate Inter- And Intrafraction Motion Dependent On Stool/gas Volume Changes For Patients Undergoing Radiotherapy With Daily Endorectal Balloon?
    Wang, K.
    Vapiwala, N.
    Deville, C.
    Plastaras, J. P.
    Bui, V.
    Bar Ad, V.
    Tochner, Z.
    Both, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S444 - S444
  • [8] Analysis of prostate bed motion using an endorectal balloon and cone beam computed tomography during postprostatectomy radiotherapy
    Joo, Ji Hyeon
    Kim, Yeon Joo
    Kim, Young Seok
    Cho, Young Pil
    Lee, Ho Yeon
    Jeong, Chang Young
    Kwak, Jungwon
    Cho, Byung Chul
    ONCOTARGETS AND THERAPY, 2016, 9 : 3095 - 3100
  • [9] Comprehensive Study on Real-time Prostate Gland Motion between Patient Groups undergoing Radiotherapy with and without Daily Endorectal Balloon
    Wang, K.
    Vapiwala, N.
    Scheuermann, R.
    Plastaras, J.
    Bar Ad, V.
    Tochner, Z.
    Both, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S683 - S684
  • [10] Initial Report of the Clinical Feasibility and Acute Toxicities Associated With Pencil Beam Scanning Whole-Pelvis Proton Therapy for Gynecologic Cancers
    Lin, L. L.
    Kirk, M. L.
    Taku, N.
    Both, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S484 - S484