Time-qualified reference values for ambulatory blood pressure monitoring in pregnancy

被引:31
|
作者
Hermida, RC
Ayala, DE
Mojón, A
Fernández, JR
机构
[1] Univ Vigo, Bioengn Lab, Vigo, Spain
[2] Univ Vigo, Chronobiol Lab, Vigo, Spain
关键词
blood pressure; heart rate; pregnancy; circadian; blood pressure monitoring; ambulatory;
D O I
10.1161/01.HYP.38.3.746
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
To recognize the highly statistically significant circadian variability of blood pressure in pregnancy is to admit that the diagnosis of gestational hypertension or preeclampsia should be based not just on whether a casual blood pressure value is too high or too low, but rather on more pertinent questions: How long is blood pressure elevated above a given time-varying threshold? What is the excess blood pressure? When does most of the excess occur? Answers to these questions may be obtained by establishing (1) an adequate reference threshold for blood pressure and (2) a proper measurement of blood pressure elevation. Accordingly, we derived time-specified reference standards for blood pressure as a function of gestational age. We analyzed 1408 blood pressure series systematically sampled by ambulatory monitoring for 48 consecutive hours every 4 weeks from the first obstetric visit (usually within the first trimester of pregnancy) until delivery in 235 women with uncomplicated pregnancies. Data from each blood pressure series were synchronized according to the rest-activity cycle of each individual to avoid differences among women in actual times of daily activity. Data were then used to compute 90% circadian tolerance intervals for each trimester of pregnancy, in keeping with the trends in blood pressure along gestation previously documented. The method, derived on the basis of bootstrap techniques, does not need to assume normality or symmetry in the data, and therefore, it is highly appropriate to describe the circadian pattern of blood pressure variability. Results not only reflect expected changes in the tolerance limits as a function of gestational age, but also upper limits markedly below the thresholds currently used for diagnosing hypertension in pregnancy. The use of these time-qualified tolerance limits for the computation of a hyperbaric index as a measure of BP excess has already been show to provide high sensitivity and specificity in the early identification of gestational hypertension and preeclampsia.
引用
收藏
页码:746 / 752
页数:7
相关论文
共 50 条
  • [1] Time-qualified reference limits for ambulatory blood pressure monitoring
    Hermida, RC
    Fernandez, JR
    Calvo, C
    Ayala, DE
    Lopez, JE
    Mojon, A
    Alonso, I
    JOURNAL OF HYPERTENSION, 2002, 20 : S226 - S226
  • [2] Circadian time-qualified tolerance intervals for ambulatory blood pressure monitoring in the diagnosis of hypertension
    Hermida, RC
    Fernández, JR
    Ayala, DE
    Mojón, A
    Alonso, I
    Calvo, C
    CHRONOBIOLOGY INTERNATIONAL, 2004, 21 (01) : 147 - 160
  • [3] Circadian time-qualified tolerance intervals for ambulatory blood pressure monitoring in the diagnosis of hypertension
    Hermida, RC
    Fernandez, JR
    Ayala, DE
    Mojon, A
    Calvo, C
    Dominguez, MJ
    Covelo, M
    Lopez, JE
    JOURNAL OF HYPERTENSION, 2004, 22 : S136 - S136
  • [4] Rationale for time-qualified reference standards for 24-hour blood pressure values and their circadian rhythms in Japanese normotensive adults - A study by the ambulatory blood pressure monitoring research group
    Kawasaki, T
    Uezono, K
    Cugini, P
    Ueno, M
    Abe, I
    Ashida, T
    Doi, M
    Ebihara, A
    Hayashi, H
    Katayama, S
    Matsuoka, H
    Ogihara, T
    Otsuka, K
    Saito, N
    Shimamoto, K
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1999, 63 (10): : 744 - 751
  • [5] Time-qualified reference limits (Chronodesms) for 24-hour blood pressure values: Classical and Bayesian
    Cugini, P
    DiPalma, L
    Ciamei, A
    DeLuca, A
    Leone, G
    Pelosio, A
    BIOLOGICAL RHYTHM RESEARCH, 1996, 27 (04) : 468 - 485
  • [6] Reference values in ambulatory blood pressure monitoring
    Koenig, W
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1998, 123 (38) : 1125 - 1125
  • [7] TIME-QUALIFIED EVALUATION OF BLOOD-PRESSURE EXCESS
    LIVI, R
    CAGNONI, S
    SECOND ANNUAL IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, 1989, : 124 - 129
  • [8] TIME-QUALIFIED REFERENCE INTERVALS - CHRONODESMS
    HALBERG, F
    LEE, JK
    NELSON, W
    EXPERIENTIA, 1978, 34 (06): : 713 - 716
  • [9] Reference values for the ambulatory blood pressure monitoring in young population
    Parenica, J
    Kubecova, L
    Spinar, J
    Nemcova, H
    JOURNAL OF HYPERTENSION, 2002, 20 : S223 - S223
  • [10] Target Blood Pressure Values in Ambulatory Blood Pressure Monitoring
    Katarzyna Lewandowska
    Stanisław Wasiliew
    Agata Kukfisz
    Michał Hofman
    Patrycja Woźniak
    Artur Radziemski
    Łukasz Stryczyński
    Dawid Lipski
    Andrzej Tykarski
    Paweł Uruski
    High Blood Pressure & Cardiovascular Prevention, 2023, 30 : 29 - 36