High spatial resolution whole-body MR angiography featuring parallel imaging:: Initial experience

被引:38
|
作者
Quick, HH [1 ]
Vogt, FM [1 ]
Madewald, S [1 ]
Herborn, CU [1 ]
Bosk, S [1 ]
Göhde, S [1 ]
Debatin, JF [1 ]
Ladd, ME [1 ]
机构
[1] Univ Klinikum Essen, Inst Diagnost & Intervent Radiol, MR Zentrum, D-45122 Essen, Germany
关键词
magnetic resonance angiography (MRA); whole-body MRA; parallel acquisition technique (PAT); high spatial resolution;
D O I
10.1055/s-2004-817623
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To combine whole-body multi-station three-dimensional contrast enhanced magnetic resonance angiography (31) CE MRA) using a self-developed rolling table platform with parallel imaging strategies (PAT) in order to increase the spatial resolution of the 3D MRA data sets. Materials and Methods: Whole-body multi-station MRA was performed with a rolling table platform (AngioSURF) on 5 volunteers in two imaging series: 1) standard imaging protocol, 2) modified high-resolution protocol employing PAT using the generalized autocalibrating partially parallel acquisitions (GRAPPA) algorithm with an acceleration factor of 3. For an intra-individual comparison of the two MR examinations, the arterial vasculature was divided into 30 segments. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated for all 30 arterial segments of each subject. Vessel segment depiction was qualitatively assessed applying a 5-point scale to each of the segments. Image reconstruction times were recorded for the standard as well as the PAT protocol. Results: Compared to the standard protocol, PAT allowed for increased spatial resolution through a 3-fold reduction in mean voxel size for each of the 5 stations. Mean SNR and CNR values over all specified vessel segments decreased by a factor of 1.58 and 1.56, respectively. Despite the reduced SNR and CNR, the depiction of all specified vessel segments increased in PAT images, reflecting the increased spatial resolution. Qualitative comparison of standard and PAT images showed an increase in vessel segment conspicuity with more detailed depiction of intramuscular arterial branches in all volunteers. The time for image data reconstruction of all 5 stations was significantly increased from about 10 minutes to 40 minutes when using the PAT acquisition. Conclusion: The implementation of PAT into the concept of whole-body MRA enabled to increase the spatial resolution in all examined territories, which resulted in more detailed MR angiograms.
引用
收藏
页码:163 / 169
页数:7
相关论文
共 50 条
  • [1] High spatial resolution whole-body MR angiography featuring parallel-imaging: Initial experience (vol 176, pg 163, 2004)
    Maderwald, S
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (04): : 622 - 622
  • [2] Whole-body MR angiography: initial experience in imaging pediatric vasculopathy
    Hong, Terence S.
    Greer, Mary-Louise C.
    Grosse-Wortmann, Lars
    Yoo, Shi-Joon
    Babyn, Paul S.
    [J]. PEDIATRIC RADIOLOGY, 2011, 41 (06) : 769 - 778
  • [3] Whole-body MR angiography: initial experience in imaging pediatric vasculopathy
    Terence S. Hong
    Mary-Louise C. Greer
    Lars Grosse-Wortmann
    Shi-Joon Yoo
    Paul S. Babyn
    [J]. Pediatric Radiology, 2011, 41 : 769 - 778
  • [4] High-spatial-resolution whole-body MR angiography with high-acceleration parallel acquisition and 32-channel 3.0-T unit: Initial experience
    Nael, Kambiz
    Fenchel, Michael
    Krishnam, Mayil
    Laub, Gerhard
    Finn, J. Paul
    Ruehm, Stefan G.
    [J]. RADIOLOGY, 2007, 242 (03) : 865 - 872
  • [5] High-spatial-resolution multistation MR angiography with parallel imaging and blood pool contrast agent: Initial experience
    Nikolaou, Konstantin
    Kramer, Harald
    Grosse, Christina
    Clevert, Dirk
    Dietrich, Olaf
    Hartmann, Mike
    Chamberlin, Paul
    Assmann, Stefan
    Reiser, Maximilian F.
    Schoenberg, Stefan O.
    [J]. RADIOLOGY, 2006, 241 (03) : 861 - 872
  • [6] Combined arterial and venous whole-body MR angiography with cardiac MR imaging in patients with thromboembolic disease - initial experience
    Vogt, Florian M.
    Hunold, Peter
    Herborn, Christoph U.
    Ruehm, Stefan G.
    Barkhausen, Joerg
    Kroger, Knut
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (05) : 983 - 992
  • [7] Combined arterial and venous whole-body MR angiography with cardiac MR imaging in patients with thromboembolic disease—initial experience
    Florian M. Vogt
    Peter Hunold
    Christoph U. Herborn
    Stefan G. Ruehm
    Joerg Barkhausen
    Knut Kroger
    [J]. European Radiology, 2008, 18 : 983 - 992
  • [8] Multistation whole-body high-spatial-resolution MR angiography using a 32-channel MR system
    Nael, Kambiz
    Ruehm, Stefan G.
    Michaely, Henrik J.
    Saleh, Roya
    Lee, Margaret
    Laub, Gerhard
    Finn, J. Paul
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (02) : 529 - 539
  • [9] Peripheral vasculature: Whole-body MR angiography with midfemoral venous compression - Initial experience
    Herborn, CU
    Ajaj, W
    Goyen, M
    Massing, S
    Ruehm, SG
    Debatin, JF
    [J]. RADIOLOGY, 2004, 230 (03) : 872 - 878
  • [10] Detection of atherosclerosis:: Systemic imaging for systemic disease with whole-body three-dimensional MR angiography -: Initial experience
    Goyen, M
    Herborn, CU
    Kröger, K
    Lauenstein, TC
    Debatin, JF
    Ruehm, SG
    [J]. RADIOLOGY, 2003, 227 (01) : 277 - 282