Using annual building energy analysis for the sizing of cooling tower for optimal chiller-cooling energy performance

被引:0
|
作者
Liu, Chia-Wei [1 ]
Chuah, Yew-Khoy [1 ]
机构
[1] Natl Taipei Univ Technol, Inst Mech & Elect Engn, Taipei 10608, Taiwan
关键词
cooling tower; chiller energy consumption; cooling tower energy consumption; building energy;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Lower condenser water temperature is an important factor for water chiller energy performance. In contrary to the usual consideration of trade off between cooling tower fan power and chiller power consumption, this study investigated the effects of oversized cooling tower on the total chiller-cooling tower energy performance. A dynamic building energy method was used in this study to compare the annual energy performance with this strategy using an office building under typical climatic conditions of tropical and subtropical regions. It has been found that oversizing cooling tower would result in ever decreasing total annual energy consumption for chillers and cooling towers as a whole. These result were obtained with different control methods used for the cooling tower falls. Moreover, this rate of decrease in total energy consumption is steepest at 10% oversize of cooling tower at standard conditions. Discussion is presented on the analysis for understanding the principles behind the results thus obtained.
引用
收藏
页码:43 / 49
页数:7
相关论文
共 50 条
  • [1] THE EFFECTS OF CAPACITY COUPLING AND WET AIR RETURN ON THE ENERGY PERFORMANCE OF CHILLER-COOLING TOWER SYSTEMS
    Liu, C. -W.
    Chuah, Y. -K.
    [J]. JOURNAL OF MECHANICS, 2011, 27 (04) : N25 - N31
  • [2] Energy performance of a cooling plant system using the inverter chiller for industrial building
    Song, Young-hak
    Akashi, Yasunori
    Yee, Jurng-Jae
    [J]. ENERGY AND BUILDINGS, 2007, 39 (03) : 289 - 297
  • [3] Matching of chiller-cooling tower to enhance efficiency of central air-conditioning plant
    Tay, SN
    Phua, KJ
    [J]. PROCEEDINGS OF THE 3RD INTERNATIONAL SYMPOSIUM ON HEAT TRANSFER ENHANCEMENT AND ENERGY CONSERVATION, VOLS 1 AND 2, 2004, : 892 - 897
  • [4] Optimal chiller loading in a district cooling system with thermal energy storage
    Powell, Kody M.
    Cole, Wesley J.
    Ekarika, Udememfon F.
    Edgar, Thomas F.
    [J]. ENERGY, 2013, 50 : 445 - 453
  • [5] Preliminary determination of pipe fouling effect for office building cooling tower energy performance
    Mohamad, Imanurezeki
    Yusof, Ahmad Anas
    Ismail, Nurul Adzura
    Daud, Al-Khairi Mohd
    Abdullah, Hayati
    Ayob, Md Razali
    [J]. PROCEEDINGS OF MECHANICAL ENGINEERING RESEARCH DAY 2018 (MERD), 2018, : 178 - 179
  • [6] Dynamics mode performance and energy analysis of building cooling systems
    Kadir, FSA
    Denman, MJ
    Eames, IW
    [J]. QUALITY RELIABILITY AND MAINTENANCE (QRM 2000), 2000, : 201 - 205
  • [7] Performance analysis of cooling tower using desiccant
    Mishra, Bhavna
    Srivastava, Aalekh
    Yadav, Laxmikant
    [J]. HEAT AND MASS TRANSFER, 2020, 56 (04) : 1153 - 1169
  • [8] Performance analysis of cooling tower using desiccant
    Bhavna Mishra
    Aalekh Srivastava
    Laxmikant Yadav
    [J]. Heat and Mass Transfer, 2020, 56 : 1153 - 1169
  • [9] Cooling tower - An energy conservation resource
    Goshayshi, HR
    Missenden, JF
    Tozer, R
    [J]. COMPACT HEAT EXCHANGERS AND ENHANCEMENT TECHNOLOGY FOR THE PROCESS INDUSTRIES, 1999, : 81 - 87
  • [10] Cooling tower - an energy conservation resource
    Goshayshi, HR
    Missenden, JF
    Tozer, R
    [J]. APPLIED THERMAL ENGINEERING, 1999, 19 (11) : 1223 - 1235