Impact of on-site wastewater infiltration systems on organic contaminants in groundwater and recipient waters

被引:24
|
作者
Gao, Qiuju [1 ]
Blum, Kristin M. [1 ]
Gago-Ferrero, Pablo [2 ]
Wiberg, Karin [2 ]
Ahrens, Lutz [2 ]
Andersson, Patrik L. [1 ]
机构
[1] Umea Univ, Dept Chem, SE-90187 Umea, Sweden
[2] Swedish Univ Agr Sci SLU, Dept Aquat Sci & Assessment, SE-75655 Uppsala, Sweden
基金
瑞典研究理事会;
关键词
Micropollutants; Environmental fate; Pharmaceuticals and personal care products; Drain field; Leach field; Decentralised wastewater treatment system; PERSONAL CARE PRODUCTS; SEPTIC SYSTEMS; PERFLUOROALKYL SUBSTANCES; AQUATIC ENVIRONMENT; FLAME RETARDANTS; PHARMACEUTICALS; REMOVAL; MICROPOLLUTANTS; FATE; HORMONES;
D O I
10.1016/j.scitotenv.2018.10.016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
On-site sewage treatment facilities, particularly septic systems combined with soil infiltration, can be an important source of emerging organic contaminants in groundwater and surface water and thus represent a significant source of environmental and human exposure. Two infiltration systems in Are municipality, Sweden, were examined to assess the occurrence of contaminants in groundwater and their fate and transport during infiltration. Groundwater samples, recipient surface water samples, and wastewater samples from septic tanks were collected from 2016 to 2017 covering all climatological seasons. These samples were analysed for a total of 103 contaminants, including pharmaceuticals, personal care products, organic phosphorus flame-retardants, plasticisers, perfluoroalkyl substances, and food additives. Fourteen of 103 contaminants showed 100% detection frequency in groundwater at concentrations in the low ng L-1 to low mu g L-1 range. Of the compounds analysed, tris(2-butoxyethyl) phosphate, sucralose, caffeine, and benzophenone showed high abundancy with maximum concentrations in the mu g L-1 range. The data were normalised for dilution using chloride and sucralose as commonly applied tracers; however, the level of sucralose decreased significantly during infiltration and it is thus suboptimal as a sewage water tracer. Large differences between the two infiltration sites were observed in detection frequencies and concentrations in groundwater, which could be attributed to the system design and the contaminant's migration time from release to sampling point. Seasonal variation was observed for selected chemicals, and the more hydrophobic chemicals showed a higher tendency for attenuation, indicating sorption as a major retention mechanism. A moderate environmental risk to aquatic organisms was estimated in adjacent surface water for galaxolide, tris(1-chloro-2-propyl) phosphate, and tris(2-butoxyethyl) phosphate. Due to this site-dependency and potential environmental risks, further studies are needed on infiltration systems in different settings and on alternative treatment techniques to reduce the contaminant discharge from on-site sewage treatment facilities. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:1670 / 1679
页数:10
相关论文
共 50 条
  • [1] Removal of Organic Contaminants in On-Site Wastewater Treatment Systems: The Role of Sorption and Transformation
    Smolinski, Rachel
    Clyde, Patricia
    Asato, Caitlin
    Brownawell, Bruce
    Gobler, Christopher
    McDonough, Carrie
    [J]. ACS ES&T WATER, 2024, 4 (09): : 4209 - 4217
  • [2] IMPACT OF NEW FEDERAL LEGISLATION ON ON-SITE WASTEWATER SYSTEMS
    DEARTH, K
    [J]. JOURNAL OF ENVIRONMENTAL HEALTH, 1978, 41 (03) : 158 - 159
  • [3] Linking Trace Organic Contaminants in On-Site Wastewater-Treatment Discharge with Biological Effects
    Warren, Les D.
    Guyader, Meaghan E.
    Kiesling, Richard L.
    Higgins, Christopher P.
    Schoenfuss, Heiko L.
    [J]. ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2021, 40 (11) : 3193 - 3204
  • [4] The impact of on-site wastewater from high density cluster developments on groundwater quality
    Morrissey, P. J.
    Johnston, P. M.
    Gill, L. W.
    [J]. JOURNAL OF CONTAMINANT HYDROLOGY, 2015, 182 : 36 - 50
  • [5] Groundwater contamination from on-site domestic wastewater management systems in a coastal catchment
    Geary, PM
    Whitehead, JH
    [J]. ON-SITE WASTEWATER TREATMENT, PROCEEDINGS, 2001, : 479 - 487
  • [6] On-site wastewater systems and interactions with the environment
    McCray, John E.
    Christopherson, Sara H.
    [J]. JOURNAL OF HYDROLOGIC ENGINEERING, 2008, 13 (08) : 653 - 654
  • [7] Groundwater mounding in the vadose zone from on-site wastewater systems: Analytical and numerical tools
    McCray, John E.
    Nieber, John
    Poeter, Eileen P.
    [J]. JOURNAL OF HYDROLOGIC ENGINEERING, 2008, 13 (08) : 710 - 719
  • [8] Controls on groundwater nitrogen contributions from on-site wastewater systems in coastal North Carolina
    Humphrey, C. P., Jr.
    O'Driscoll, M. A.
    Zarate, M. A.
    [J]. WATER SCIENCE AND TECHNOLOGY, 2010, 62 (06) : 1448 - 1455
  • [9] Impact of on-site sanitation systems on groundwater sources in a coastal aquifer in Chennai, India
    Jangam, Chandrakant
    Pujari, Paras
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2019, 26 (03) : 2079 - 2088
  • [10] Impact of on-site sanitation systems on groundwater sources in a coastal aquifer in Chennai, India
    Chandrakant Jangam
    Paras Pujari
    [J]. Environmental Science and Pollution Research, 2019, 26 : 2079 - 2088