Evaluation of Dose Distribution According to Patient Setup Errors in Pediatric Head CT Examination: A Phantom Study

被引:1
|
作者
Gotanda, Rumi [1 ]
Takeda, Yoshihiro [2 ]
Gotanda, Tatsuhiro [3 ]
Ota, Kosuke [1 ]
Akagawa, Takuya [4 ]
Tabuchi, Akihiko [5 ]
Kuwano, Tadao [6 ]
Yatake, Hidetoshi [7 ]
Yabunaka, Koichi [8 ]
Sato, Hitoshi [1 ]
Katsuda, Toshizo [9 ]
机构
[1] Ibaraki Prefectural Univ Hlth Sci, Dept Radiol Sci, Ami, Ibaraki, Japan
[2] Okayama Univ, Grad Sch Hlth Sci, Okayama, Japan
[3] Junshin Gakuen Univ, Fac Hlth Sci, Dept Radiol Sci, Fukuoka, Japan
[4] Tokushima Red Cross Hosp, Dept Radiol Technol, Tokushima, Japan
[5] Kawasaki Hosp, Dept Radiol, Okayama, Japan
[6] Osaka Ctr Canc & Cardiovasc Dis Prevent, Osaka, Japan
[7] Kaizuka City Hosp, Dept Radiol, Osaka, Japan
[8] Katuragi Hosp, Dept Radiol, Osaka, Japan
[9] Tokai Gakuin Univ, Dept Hlth & Welf, Gifu, Japan
关键词
computed tomography; pediatric; phantom; radiation dosimetry; radiochromic film; RADIOCHROMIC FILM;
D O I
10.1007/978-3-319-11128-5_56
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Radiation doses during computed tomography (CT) examinations are generally evaluated by CT dose index (CTDI). The CTDI is measured by means of a CTDI phantom, which is placed in the center of the CT gantry aperture. However, patients are not always positioned in the centered in clinical settings. In this study, dose distributions associated with patient setup errors and head size were evaluated using phantoms developed for pediatric patients. The phantoms were made using flexible acrylic sheets in a cylindrical shape [diameters of 6 (premature baby), 8 (neonate), 10 (infant), and 12 cm (child)] and placed on the end of the CT bed. The bed position was lowered from the center by up to a radius length for each phantom size. Dose distributions in the phantoms were measured using radiochromic film. By lowering the bed position, the surface doses at 0 degrees increased and those at 180 degrees and the center doses decreased. However, the other measurement positions exhibited complex changes depending on the phantom size. In addition, the shapes of the dose profile curves varied according to the distance from the X-ray tube (i.e. location in the gantry aperture). In this study, the surface doses became smaller with decreasing distance from the X-ray tube. Therefore, decreasing the distance from the lens to the X-ray tube would be an effective way to reduce the absorbed dose of the lens. However, the dose distributions in the phantoms varied in a complex manner depending on patient setup errors and phantom size. In addition, beam slice width and pitch were important factors in determining the amount of the CT dose. To keep radiation doses during CT examination as low as reasonably achievable, it is important to clarify the influence of CT scanning settings on CT dose.
引用
收藏
页码:224 / 227
页数:4
相关论文
共 50 条
  • [1] valuation of the eye lens dose according to patient setup errors in pediatric head CT examination
    Gotanda, R.
    Katsuda, T.
    Gotanda, T.
    Noguchi, K.
    Nakajima, E.
    Akagawa, T.
    Tanki, N.
    Tabuchi, A.
    Kuwano, T.
    Shimono, T.
    Kawaji, Y.
    Sato, H.
    Takeda, Y.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 720 - 723
  • [2] Dose Distribution in Pediatric CT Head Examination: Phantom Study
    Gotanda, R.
    Katsuda, T.
    Gotanda, T.
    Tabuchi, A.
    Yatake, H.
    Takeda, Y.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 775 - 779
  • [3] Dose Distribution in Pediatric CT Head Examination: Phantom Study
    Gotanda, R.
    Katsuda, T.
    Gotanda, T.
    Tabuchi, A.
    Kuwano, T.
    Yatakes, H.
    Yabunaka, K.
    Akagawa, T.
    Sato, H.
    Takeda, Y.
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 547 - +
  • [4] Evaluation of radiation dose in pediatric head CT examination: a phantom study
    Din, Nik Norhasrina Nik
    Zainon, Rafidah
    Rahman, Ahmad Taufek Abdul
    INTERNATIONAL NUCLEAR SCIENCE, TECHNOLOGY AND ENGINEERING CONFERENCE 2017 (INUSTEC2017), 2018, 298
  • [5] Dose distribution in pediatric CT head examination using a new phantom with radiochromic film
    R. Gotanda
    T. Katsuda
    T. Gotanda
    A. Tabuchi
    H. Yatake
    Y. Takeda
    Australasian Physics & Engineering Sciences in Medicine, 2008, 31 : 339 - 344
  • [6] Dose distribution in pediatric CT head examination using a new phantom with radiochromic film
    Gotanda, R.
    Katsuda, T.
    Gotanda, T.
    Tabuchi, A.
    Yatake, H.
    Takeda, Y.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2008, 31 (04) : 339 - 344
  • [7] Evaluation of head and neck patient setup and immobilization errors
    Robison, B.
    Seibert, R.
    Ramsey, C. R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S667 - S668
  • [8] The effects of mis-centering on radiation dose during CT head examination: A phantom study
    Isa, I. N. C.
    Rahmat, S. M. S.
    Dom, S. M.
    Kayun, Z.
    Karim, M. K. A.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (04) : 631 - 639
  • [9] A head phantom study for intraocular dose evaluation of 64-slice multidetector CT examination in patients with suspected cranial trauma
    Matsubara, Kosuke
    Koshida, Kichiro
    Noto, Kimiya
    Takata, Tadanori
    Suzuki, Masayuki
    Shimono, Tetsunori
    Yamamoto, Tomoyuki
    Matsui, Osamu
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (02) : 283 - 287
  • [10] Evaluation of Organ Dose and Image Quality Metrics of Pediatric CT Chest-Abdomen-Pelvis (CAP) Examination: An Anthropomorphic Phantom Study
    Muhammad, Nor Azura
    Kayun, Zunaide
    Abu Hassan, Hasyma
    Wong, Jeannie Hsiu Ding
    Ng, Kwan Hoong
    Karim, Muhammad Khalis Abdul
    APPLIED SCIENCES-BASEL, 2021, 11 (05): : 1 - 13