Inter-user and intra-user variation of two tonometers in horses

被引:8
|
作者
Lewin, Andrew C. [1 ]
Liu, Chin-Chi [1 ]
Camacho-Luna, Pilar [1 ]
Alling, Christopher [1 ]
Carter, Renee T. [1 ]
机构
[1] Louisiana State Univ, Sch Vet Med, Skip Bertman Dr, Baton Rouge, LA 70803 USA
关键词
horse; tonometer; TonoPen; TonoVet; variability; variation; INTRAOCULAR-PRESSURE MEASUREMENT; GOLDMANN APPLANATION TONOMETER; REBOUND TONOMETER; ROMIFIDINE; XYLAZINE; DOGS;
D O I
10.1111/evj.13208
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background It is currently unknown which of the two devices most commonly used in equine ophthalmology for intraocular pressure (IOP) estimation demonstrates the lowest inter-user and intra-user variation. Objectives To assess the inter-user and intra-user variation of two tonometers in sedated and unsedated horses. Study design Randomised masked cross-over trial. Methods Four examiners used the rebound (ICare (R) TonoVet) and applanation (TonoPen (R)) tonometers to measure the intraocular pressure (IOP) in triplicate in 10 normal horses before and after sedation with xylazine. For inter-user variation, coefficient of variation (CV) values were calculated from the mean of each examiner for each condition combination. For intra-user variation, CV values were calculated from the individual measurements of each examiner for each condition combination. CV values were also assessed in relation to other variables using ANOVA. Results The rebound tonometer was found to have lower inter-user (15.4% vs 21.7%, P = .01) and intra-user (9.1% vs 16.1%, P < .0001) variation in unsedated horses and lower intra-user (8.4% vs 14.7%, P < .0001) variation in sedated horses than the applanation tonometer. Both instruments had similar inter-user variation in sedated horses. For the rebound tonometer, sedation did not affect inter-user or intra-user variation, but for the applanation tonometer inter-user variation was lowest while horses were sedated (16.0% vs 21.7%, P = .03). No other variable assessed was found to have an effect on IOP. Main limitations No animals with ocular disease were included in this study. Conclusions The rebound tonometer may be the preferred instrument to minimise intra-user and inter-user variation for IOP measurement in unsedated horses. The rebound tonometer is also likely to be the preferred instrument to minimise intra-user variation in sedated horses. If the applanation tonometer is used to perform IOP measurement in horses, it is recommended that this is performed while horses are sedated to minimise inter-user variation for this instrument.
引用
收藏
页码:572 / 576
页数:5
相关论文
共 50 条
  • [1] INTER- AND INTRA-USER VARIABILITY OF THE SYNTAX SCORE
    Levine, Evan
    Basman, Craig
    Tejpal, Astha
    Barry, Ryan
    Thampi, Shankar
    Rashid, Umar
    Coplan, Neil
    Singh, Varinder P.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1353 - 1353
  • [2] Inter- and intra-user variations in film based IMRT QA
    Chase, D.
    Ramsey, C.
    Robison, B.
    Seibert, R.
    Harris, C.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2247 - 2247
  • [3] Study of Intra- and Inter-user Variance in Password Keystroke Dynamics
    Ayotte, Blaine
    Banavar, Mahesh
    Hou, Daqing
    Schuckers, Stephanie
    [J]. ICISSP: PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON INFORMATION SYSTEMS SECURITY AND PRIVACY, 2021, : 467 - 474
  • [4] The Intra- and Inter-User Reliability of Testicular Volume Estimation - A Simulation Study
    De Silva, Shamani
    Akbarian-Tefaghi, Ladan
    Langley, Joseph
    Stanton, Andrew
    Wright, Neil P.
    Elder, Charlotte J.
    [J]. HORMONE RESEARCH IN PAEDIATRICS, 2016, 86 : 427 - 427
  • [5] Intra-/Inter-user Adaptation Framework for Wearable Gesture Sensing Device
    Kikui, Kosuke
    Itoh, Yuta
    Yamada, Makoto
    Sugiura, Yuta
    Sugimoto, Maki
    [J]. ISWC'18: PROCEEDINGS OF THE 2018 ACM INTERNATIONAL SYMPOSIUM ON WEARABLE COMPUTERS, 2018, : 21 - 24
  • [6] Adaptive Techniques for Intra-User Variability in Keystroke Dynamics
    Ceker, Hayreddin
    Upadhyaya, Shambhu
    [J]. 2016 IEEE 8TH INTERNATIONAL CONFERENCE ON BIOMETRICS THEORY, APPLICATIONS AND SYSTEMS (BTAS), 2016,
  • [7] Inter-user variability of the BAT ultrasound system
    Lagen, K
    Pouliot, J
    Anezinos, C
    Aubin, M
    Hsu, I
    Gottschalk, A
    Lowther, D
    Shinohara, K
    Verhey, L
    Roach, R
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1308 - 1309
  • [8] Categories of auditory performance: inter-user reliability
    Archbold, S
    Lutman, ME
    Nikolopoulos, T
    [J]. BRITISH JOURNAL OF AUDIOLOGY, 1998, 32 (01): : 7 - 11
  • [9] INTER-USER INTERFERENCE IN MOLECULAR COMMUNICATION NETWORKS
    Jiang, Chunxiao
    Chen, Yan
    Liu, K. J. Ray
    [J]. 2014 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2014,
  • [10] EVDO intra-user QoS分析及应用
    李海枫
    [J]. 长江信息通信, 2013, (10) : 175 - 177