Investigating the Prediction Accuracy of Recently Updated Intraocular Lens Power Formulas with Artificial Intelligence for High Myopia

被引:13
|
作者
Omoto, Miki [1 ]
Sugawara, Kaoruko [1 ]
Torii, Hidemasa [1 ]
Yotsukura, Erisa [1 ]
Masui, Sachiko [1 ]
Shigeno, Yuta [1 ]
Nishi, Yasuyo [1 ]
Negishi, Kazuno [1 ]
机构
[1] Keio Univ, Sch Med, Dept Ophthalmol, Tokyo 1608582, Japan
关键词
cataract; intraocular lens; artificial intelligence; AXIAL LENGTH; EYES;
D O I
10.3390/jcm11164848
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to investigate the prediction accuracy of intraocular lens (IOL) power formulas with artificial intelligence (AI) for high myopia. Cases of highly myopic patients (axial length [AL], >26.0 mm) undergoing uncomplicated cataract surgery with at least 1-month follow-up were included. Prediction errors, absolute errors, and percentages of eyes with prediction errors within +/- 0.25, +/- 0.50, and +/- 1.00 diopters (D) were compared using five formulas: Hill-RBF3.0, Kane, Barrett Universal II (BUII), Haigis, and SRK/T. Seventy eyes (mean patient age at surgery, 64.0 +/- 9.0 years; mean AL, 27.8 +/- 1.3 mm) were included. The prediction errors with the Hill-RBF3.0 and Kane formulas were statistically different from the BUII, Haigis, and SRK/T formulas, whereas there was not a statistically significant difference between those with the Hill-RBF3.0 and Kane. The absolute errors with the Hill-RBF3.0 and Kane formulas were smaller than that with the BUII formula, whereas there was not a statistically significant difference between the other formulas. The percentage within +/- 0.25 D with the Hill-RBF3.0 formula was larger than that with the BUII formula. The prediction accuracy using AI (Hill-RBF3.0 and Kane) showed excellent prediction accuracy. No significant difference was observed in the prediction accuracy between the Hill-RBF3.0 and Kane formulas.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Accuracy of the refractive prediction determined by intraocular lens power calculation formulas in high myopia
    Zhou, Dong
    Sun, Zhuo
    Deng, Guohua
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (04) : 484 - 489
  • [2] Accuracy of the refractive prediction determined by intraocular lens power calculation formulas in high myopia
    Shrivastava, Ankur K.
    Behera, Pranayee
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (11) : 1905 - +
  • [3] Accuracy of modern intraocular lens power calculation formulas in refractive lens exchange for high myopia and high hyperopia
    Terzi, Evdoxia
    Wang, Li
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (07): : 1181 - 1189
  • [4] A Comparison of Intraocular Lens Power Calculation Formulas in High Myopia
    Bernardes, Joao
    Raimundo, Miguel
    Lobo, Conceicao
    Murta, Joaquim Neto
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (03) : 207 - +
  • [5] Comparison of intraocular lens power formulas for negative diopter intraocular lens implantation for high myopia
    Whang, Woong-Joo
    Koh, Kyungmin
    Hoffer, Kenneth J.
    Schiano-Lomoriello, Domenico
    Lupardi, Enrico
    Taroni, Leonardo
    Tchah, Hungwon
    Savini, Giacomo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2025, 51 (02): : 119 - 125
  • [6] Comparative accuracy of intraocular lens power calculation formulas when targeting myopia
    Yang, Soonwon
    Park, Chanjoon
    Byun, Yong-Soo
    Chung, So-Hyang
    Kim, Hyun Seung
    HELIYON, 2024, 10 (13)
  • [7] A Review of Intraocular Lens Power Calculation Formulas Based on Artificial Intelligence
    Stopyra, Wiktor
    Cooke, David L.
    Grzybowski, Andrzej
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (02)
  • [8] Analysis of accuracy of twelve intraocular lens power calculation formulas for eyes with axial myopia
    Stopyra, Wiktor
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2023, 13 (02) : 225 - 230
  • [9] Intraocular lens power calculation formulas in Chinese eyes with high axial myopia
    Tsang, CSL
    Chong, GSL
    Yiu, EPF
    Ho, CK
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (07): : 1358 - 1364
  • [10] Accuracy of 7 Artificial Intelligence-Based Intraocular Lens Power Calculation Formulas in Extremely Long Caucasian Eyes
    Stopyra, Wiktor
    Voytsekhivskyy, Oleksiy
    Grzybowski, Andrzej