摘要
The objective of this study was to optimize the physicodynamic conditions of polymeric system as a coating substrate for drug eluting stents against restenosis. As Nitric Oxide (NO) has multifunctional activities, such as regulating blood flow and pressure, and influencing thrombus formation, a continuous and spatiotemporal delivery of NO loaded in the polymer based nanoparticles could be a viable option to reduce and prevent restenosis. To identify the most suitable carrier for S-Nitrosoglutathione (GSNO), a NO prodrug, stents were coated with various polymers, such as poly (lactic-co-glycolic acid) (PLGA), polyethylene glycol (PEG) and polycaprolactone (PCL), using solvent evaporation technique. Full factorial design was used to evaluate the effects of the formulation variables in polymer-based stent coatings on the GSNO release rate and weight loss rate. The least square regression model was used for data analysis in the optimization process. The polymer-coated stents were further assessed with Differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy analysis (FTIR), Scanning electron microscopy (SEM) images and platelet adhesion studies. Stents coated with PCL matrix displayed more sustained and controlled drug release profiles than those coated with PLGA and PEG. Stents coated with PCL matrix showed the least platelet adhesion rate. Subsequently, stents coated with PCL matrix were subjected to the further optimization processes for improvement of surface morphology and enhancement of the drug release duration. The results of this study demonstrated that PCL matrix containing GSNO is a promising system for stent surface coating against restenosis.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] 3(3) factorial design-based optimization of the formulation of nitrofurantoin microcapsules
    Karasulu, HY
    Ertan, G
    Guneri, T
    [J]. PHARMACY WORLD & SCIENCE, 1996, 18 (01): : 20 - 25
  • [2] Design-based analysis of factorial designs embedded in probability samples
    van den Brakel, Jan A.
    [J]. SURVEY METHODOLOGY, 2013, 39 (02) : 323 - 349
  • [3] FACTORIAL DESIGN-BASED OPTIMIZATION OF THE FORMULATION OF ISOSORBIDE-5-MONONITRATE MICROCAPSULES
    FARIVAR, M
    KAS, HS
    ONER, L
    HINCAL, AA
    [J]. JOURNAL OF MICROENCAPSULATION, 1993, 10 (03) : 309 - 317
  • [4] miR-22 eluting cardiovascular stent based on a self-healable spongy coating inhibits in-stent restenosis
    Wang, Jing
    Qian, Hong-Lin
    Chen, Sheng-Yu
    Huang, Wei-Pin
    Huang, Dan-Ni
    Hao, Hong-Ye
    Ren, Ke-Feng
    Wang, Yun-Bing
    Fu, Guo-Sheng
    Ji, Jian
    [J]. BIOACTIVE MATERIALS, 2021, 6 (12) : 4686 - 4696
  • [5] Formulation, evaluation and 32 full factorial design-based optimization of ondansetron hydrochloride incorporated taste masked microspheres
    Kharb, Vandana
    Saharan, Vikas Anand
    Dev, Kapil
    Jadhav, Hemant
    Purohit, Suresh
    [J]. PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2014, 19 (07) : 839 - 852
  • [6] Statistical Optimization of Urinary Organic Acids Analysis by a Multi-Factorial Design of Experiment
    Pazzi, Marco
    Colella, Sara
    Alladio, Eugenio
    Puccinelli, M. Paola
    Mengozzi, Giulio
    Medana, Claudio
    [J]. ANALYTICA, 2020, 1 (01):
  • [7] A Full Factorial Design-Based Desirability Function Approach for Optimization of Hot Forged Vanadium Micro-alloyed Steel
    Equbal M.I.
    Equbal A.
    Mukerjee D.
    [J]. Metallography, Microstructure, and Analysis, 2018, 7 (05) : 504 - 523
  • [8] OPTIMIZATION OF ELECTRODES CONDITIONS PREPARATION BASED CARBON CERAMIC USING FACTORIAL DESIGN.
    Skeika, Tatiane
    Pessoa, Christiana
    Fujiwara, Sergio Toshio
    Nagata, Noemi
    [J]. QUIMICA NOVA, 2010, 33 (03): : 629 - 633
  • [9] Analysis of the mechanical performance of a cardiovascular stent design based on micromechanical modelling
    McGarry, JP
    O'Donnell, BP
    McHugh, PE
    McGarry, JG
    [J]. COMPUTATIONAL MATERIALS SCIENCE, 2004, 31 (3-4) : 421 - 438
  • [10] Optimization Studies of Elemental Composition of Composite Polymer for Neutron Shielding Using Factorial Design Analysis
    Basu, Pew
    Sarangapani, R.
    Datta, D.
    Venkatraman, B.
    [J]. NUCLEAR TECHNOLOGY, 2022, 208 (07) : 1192 - 1204