Microcuff paediatric tracheal tube. A new tracheal tube with a high volume-low pressure cuff for children

被引:41
|
作者
Weiss, M [1 ]
Dullenkopf, A [1 ]
Gerber, AC [1 ]
机构
[1] Univ Zurich, Kinderklin, Anasthesieabt, CH-8032 Zurich, Switzerland
来源
ANAESTHESIST | 2004年 / 53卷 / 01期
关键词
intubation; tracheal tube; cuff; paediatrics; high volume-low pressure;
D O I
10.1007/s00101-003-0604-x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Principles and characteristics of the recently introduced Microcuff paediatric tracheal tube (Microcuff, GmbH, Weinheim, Germany) with anatomically based depth markings, cuff-free subglottic tube shaft and short high volume-low pressure cuff with ultrathin cuff membrane are presented. First available tubes (ID 4.0 mm) were evaluated regarding cuff pressures required to seal the trachea and regarding the distance from the tube tip to the carina. Methods. After obtaining approval of the local ethical committee, 20 children aged 2-4 years, receiving tracheal intubation under general anaesthesia with muscle paralysis, were included. The tubes were placed during direct laryngoscopy and glottic depth marking placed between the vocal cords. Cuff pressure to prevent audible air leakage at standardised ventilator settings (PIP 20 cmH(2)O/PEEP 5 cmH(2)O/RR20*min(-1)) was assessed by means of a cuff pressure manometer within 5 min after intubation. Subsequently, the distance from the tube tip to the tracheal carina was measured by means of fibre bronchoscopy. Data are presented as the median (range). Results. Patient age was 3.0 years (2.0-3.9 years), weight 13.5 kg (9.1-19.2 kg) and body length 95 cm (79-105 cm). The lowest cuff pressure required to seal the trachea ranged from 4-14 cmH(2)O (median 10 cmH(2)O), the distance from tube tip to tracheal carina was to 2.9 cm (2.0-4.5 cm). Conclusions. The new Microcuff paediatric tracheal tube with ultrathin high volume-low pressure cuff required tracheal sealing pressures below tracheal wall pressures usually required with uncuffed tracheal tubes for efficient sealing ventilation at 20cmH(2)O peak inspiratory pressure. The distance from the tube tip to carina was in the safe range in all patients.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 50 条
  • [1] Fit and seal characteristics of a new paediatric tracheal tube with high volume-low pressure polyurethane cuff
    Dullenkopf, A
    Gerber, AC
    Weiss, M
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2005, 49 (02) : 232 - 237
  • [2] Closed tracheal suction and fluid aspiration past the tracheal tube. Impact of tube cuff and airway pressure
    Dave, M. H.
    Frotzler, A.
    Weiss, M.
    MINERVA ANESTESIOLOGICA, 2011, 77 (02) : 166 - 171
  • [3] TRACHEAL TUBE CUFF PRESSURE
    MEHTA, S
    ANAESTHESIA, 1989, 44 (12) : 1001 - 1002
  • [4] TRACHEAL TUBE CUFF PRESSURE
    CLEMENSEN, S
    ANAESTHESIA, 1985, 40 (08) : 825 - 825
  • [5] A PRESSURE REGULATOR FOR THE CUFF OF A TRACHEAL TUBE
    MILLER, DM
    ANAESTHESIA, 1992, 47 (07) : 594 - 596
  • [6] Adjusting tracheal tube cuff pressure
    Kunstyr, Jan
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2015, 32 (04) : 280 - 280
  • [7] TRACHEAL TUBE CUFF PRESSURE - REPLY
    LATTO, IP
    WILLIS, BA
    ANAESTHESIA, 1989, 44 (12) : 1002 - 1002
  • [8] Pressure-volume relationship for paediatric cuffed tracheal tube
    Devys, JM
    Guellec, V
    Mourès, JM
    Plaud, B
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2003, 22 (04): : 291 - 295
  • [9] The tracheal tube with a high-volume, low-pressure cuff at various airway inflation pressures
    Inada, T
    Uesugi, F
    Kawachi, S
    Inada, K
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1998, 15 (06) : 629 - 632
  • [10] A low-volume, low-pressure tracheal tube cuff reduces pulmonary aspiration
    Young, PJ
    Pakeerathan, S
    Blunt, MC
    Subramanya, S
    CRITICAL CARE MEDICINE, 2006, 34 (03) : 632 - 639