Performance of the LHCb RICH detectors during the LHC Run II

被引:6
|
作者
Papanestis, A. [1 ]
D'Ambrosio, C. [2 ]
机构
[1] Rutherford Appleton Lab, STFC, Didcot, Oxon, England
[2] CERN, Geneva, Switzerland
关键词
Cherenkov radiation; LHCb RICH;
D O I
10.1016/j.nima.2017.03.009
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The LHCb RICH system provides hadron identification over a wide momentum range (2-100 GeV/c). This detector system is key to LHCb's precision flavour physics programme, which has unique sensitivity to physics beyond the standard model. This paper reports on the performance of the LHCb RICH in Run II, following significant changes in the detector and operating conditions. The changes include the refurbishment of significant number of photon detectors, assembled using new vacuum technologies, and the removal of the aerogel radiator. The start of Run II of the LHC saw the beam energy increase to 6.5 TeV per beam and a new trigger strategy for LHCb with full online detector calibration. The RICH information has also been made available for all trigger streams in the High Level Trigger for the first time.
引用
收藏
页码:221 / 224
页数:4
相关论文
共 50 条
  • [1] Performance of the LHCb RICH detectors during LHC Run 2
    Calabrese, R.
    Fiorini, M.
    Luppi, E.
    Minzoni, L.
    Slazyk, I.
    Tomassetti, L.
    Bartolini, M.
    Cardinale, R.
    Fontanelli, F.
    Petrolini, A.
    Pistone, A.
    Calvi, M.
    Matteuzzi, C.
    Lupato, A.
    Simi, G.
    Kucharczyk, M.
    Malecki, B.
    Witek, M.
    Benson, S.
    Blago, M.
    Cavallero, G.
    Contu, A.
    D'Ambrosio, C.
    Frei, C.
    Gys, T.
    He, J.
    Piedigrossi, D.
    Wyllie, K.
    Adinolfi, M.
    Chapman, M. G.
    Dalseno, J.
    Harnew, S.
    Maddrell-Mander, S.
    Naik, P.
    Prouve, C.
    Rademacker, J.
    Solomin, A.
    Tico, J. Garra
    Jones, C. R.
    Tolk, S.
    Wotton, S. A.
    Easo, S.
    Papanestis, A.
    Wilson, F. F.
    Carson, L.
    Eisenhardt, S.
    Gambetta, S.
    Gizdov, K.
    Luo, H.
    Morris, A.
    [J]. JOURNAL OF INSTRUMENTATION, 2022, 17 (07)
  • [2] The Performance of the LHCb RICH Detectors
    Easo, Sajan
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 829 - 830
  • [3] Performance of the LHCb outer tracker in run-I and run-II of the LHC
    Bachmann, Sebastian
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1069
  • [4] Performance of the RICH detectors of LHCb
    Papanestis, A.
    [J]. PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011), 2012, 37 : 613 - 620
  • [5] The upgrade of the LHCb RICH system for the LHC Run 3
    Papanestis, A.
    Keizer, F.
    Wotton, S. A.
    [J]. JOURNAL OF INSTRUMENTATION, 2020, 15 (09):
  • [6] Preparation and commissioning of LHCb for the Run II of LHC
    Puig, A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 35 - 37
  • [7] Performance of the LHCb RICH detector at the LHC
    Adinolfi, M.
    Rinella, G. Aglieri
    Albrecht, E.
    Bellunato, T.
    Benson, S.
    Blake, T.
    Blanks, C.
    Brisbane, S.
    Brook, N. H.
    Calvi, M.
    Cameron, B.
    Cardinale, R.
    Carson, L.
    Contu, A.
    Coombes, M.
    D'Ambrosio, C.
    Easo, S.
    Egede, U.
    Eisenhardt, S.
    Fanchini, E.
    Fitzpatrick, C.
    Fontanelli, F.
    Forty, R.
    Frei, C.
    Gandini, P.
    Gao, R.
    Tico, J. Garra
    Giachero, A.
    Gibson, V.
    Gotti, C.
    Gregson, S.
    Gys, T.
    Haines, S. C.
    Hampson, T.
    Harnew, N.
    Hill, D.
    Hunt, P.
    John, M.
    Jones, C. R.
    Johnson, D.
    Kanaya, N.
    Katvars, S.
    Kerzel, U.
    Kim, Y. M.
    Koblitz, S.
    Kucharczyk, M.
    Lambert, D.
    Main, A.
    Maino, M.
    Malde, S.
    [J]. EUROPEAN PHYSICAL JOURNAL C, 2013, 73 (05): : 1 - 17
  • [8] Performance of the LHCb RICH detector at the LHC
    M. Adinolfi
    G. Aglieri Rinella
    E. Albrecht
    T. Bellunato
    S. Benson
    T. Blake
    C. Blanks
    S. Brisbane
    N. H. Brook
    M. Calvi
    B. Cameron
    R. Cardinale
    L. Carson
    A. Contu
    M. Coombes
    C. D’Ambrosio
    S. Easo
    U. Egede
    S. Eisenhardt
    E. Fanchini
    C. Fitzpatrick
    F. Fontanelli
    R. Forty
    C. Frei
    P. Gandini
    R. Gao
    J. Garra Tico
    A. Giachero
    V. Gibson
    C. Gotti
    S. Gregson
    T. Gys
    S. C. Haines
    T. Hampson
    N. Harnew
    D. Hill
    P. Hunt
    M. John
    C. R. Jones
    D. Johnson
    N. Kanaya
    S. Katvars
    U. Kerzel
    Y. M. Kim
    S. Koblitz
    M. Kucharczyk
    D. Lambert
    A. Main
    M. Maino
    S. Malde
    [J]. The European Physical Journal C, 2013, 73
  • [9] The LHCb RICH detectors: Operations and performance
    Gambetta, S.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 952
  • [10] Performance of the LHCb tracking system in Run I of the LHC
    Davis, Adam C. S.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 15 - 17