Effects of pre-analytical processes on blood samples used in metabolomics studies

被引:192
|
作者
Yin, Peiyuan [1 ]
Lehmann, Rainer [2 ,3 ,4 ]
Xu, Guowang [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China
[2] Univ Tubingen Hosp, Div Clin Chem & Pathobiochem, Cent Lab, D-72076 Tubingen, Germany
[3] Univ Tubingen, Inst Diabet Res & Metab Dis IDM, Helmholtz Ctr Munich, D-72076 Tubingen, Germany
[4] German Ctr Diabet Res DZD, D-72076 Tubingen, Germany
基金
中国国家自然科学基金;
关键词
Metabolomics; Preanalytical; Bias; Blood; Urine; Serum; Plasma; Liquid chromatography-mass spectrometry; Standard operation procedure; Biobank; CHROMATOGRAPHY-MASS SPECTROMETRY; FREEZE-THAW CYCLES; INTERNAL BODY TIME; -20; DEGREES-C; LIQUID-CHROMATOGRAPHY; HUMAN PLASMA; CLINICAL-APPLICATIONS; POTENTIAL BIOMARKERS; METABOLITE PROFILES; GAS-CHROMATOGRAPHY;
D O I
10.1007/s00216-015-8565-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Every day, analytical and bio-analytical chemists make sustained efforts to improve the sensitivity, specificity, robustness, and reproducibility of their methods. Especially in targeted and non-targeted profiling approaches, including metabolomics analysis, these objectives are not easy to achieve; however, robust and reproducible measurements and low coefficients of variation (CV) are crucial for successful metabolomics approaches. Nevertheless, all efforts from the analysts are in vain if the sample quality is poor, i.e. if preanalytical errors are made by the partner during sample collection. Preanalytical risks and errors are more common than expected, even when standard operating procedures (SOP) are used. This risk is particularly high in clinical studies, and poor sample quality may heavily bias the CV of the final analytical results, leading to disappointing outcomes of the study and consequently, although unjustified, to critical questions about the analytical performance of the approach from the partner who provided the samples. This review focuses on the preanalytical phase of liquid chromatography-mass spectrometry-driven metabolomics analysis of body fluids. Several important preanalytical factors that may seriously affect the profile of the investigated metabolome in body fluids, including factors before sample collection, blood drawing, subsequent handling of the whole blood (transportation), processing of plasma and serum, and inadequate conditions for sample storage, will be discussed. In addition, a detailed description of latent effects on the stability of the blood metabolome and a suggestion for a practical procedure to circumvent risks in the preanalytical phase will be given.
引用
收藏
页码:4879 / 4892
页数:14
相关论文
共 50 条
  • [1] Effects of pre-analytical processes on blood samples used in metabolomics studies
    Peiyuan Yin
    Rainer Lehmann
    Guowang Xu
    [J]. Analytical and Bioanalytical Chemistry, 2015, 407 : 4879 - 4892
  • [2] The key points in the pre-analytical procedures of blood and urine samples in metabolomics studies
    Bi, Hai
    Guo, Zhengyang
    Jia, Xiao
    Liu, Huiying
    Ma, Lulin
    Xue, Lixiang
    [J]. METABOLOMICS, 2020, 16 (06)
  • [3] The key points in the pre-analytical procedures of blood and urine samples in metabolomics studies
    Hai Bi
    Zhengyang Guo
    Xiao Jia
    Huiying Liu
    Lulin Ma
    Lixiang Xue
    [J]. Metabolomics, 2020, 16
  • [4] Quality controls in biobank samples: effects of pre-analytical factors on blood samples used in gene expression studies
    Valentino, P.
    Marnetto, F.
    Caldano, M.
    Bertolo, J.
    Martire, S.
    Bertolotto, A.
    [J]. MULTIPLE SCLEROSIS JOURNAL, 2018, 24 : 890 - 891
  • [5] The Effect of Pre-Analytical Conditions on Blood Metabolomics in Epidemiological Studies
    Ferreira, Diana L. Santos
    Maple, Hannah J.
    Goodwin, Matt
    Brand, Judith S.
    Yip, Vikki
    Min, Josine L.
    Groom, Alix
    Lawlor, Debbie A.
    Ring, Susan
    [J]. METABOLITES, 2019, 9 (04):
  • [6] Recommendations and Best Practices for Standardizing the Pre-Analytical Processing of Blood and Urine Samples in Metabolomics
    Gonzalez-Dominguez, Raul
    Gonzalez-Dominguez, Alvaro
    Sayago, Ana
    Fernandez-Recamales, Angeles
    [J]. METABOLITES, 2020, 10 (06) : 1 - 18
  • [7] Practical methods for pre-analytical evaluation of blood donor samples
    Robertson, G
    Blackburn, G
    Shaffer, S
    Rasey, M
    Houghton, K
    [J]. TRANSFUSION, 2004, 44 (09) : 165A - 166A
  • [8] The pre-analytical processing of blood samples for detecting biomarkers on protein microarrays
    Rosskopf, Sandra
    Gyurjan, Istvan
    Luna-Coronell, Johana A.
    Vierlinger, Klemens
    Singer, Christian F.
    Rappaport, Christine
    Pecha, Nina
    Weinhaeusel, Andreas
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2015, 418 : 39 - 51
  • [9] Identification of Clinical Biomarkers for Pre-Analytical Quality Control of Blood Samples
    Kang, Hyun Ju
    Jeon, Soon Young
    Park, Jae-Sun
    Yun, Ji Young
    Kil, Han Na
    Hong, Won Kyung
    Lee, Mee-Hee
    Kim, Jun-Woo
    Jeon, Jae-Pil
    Han, Bok Ghee
    [J]. BIOPRESERVATION AND BIOBANKING, 2013, 11 (02) : 94 - 100
  • [10] Biomarkers for Monitoring Pre-Analytical Quality Variation of mRNA in Blood Samples
    Zhang, Hui
    Korenkova, Vlasta
    Sjoback, Robert
    Svec, David
    Bjorkman, Jens
    Kruhoffer, Mogens
    Verderio, Paolo
    Pizzamiglio, Sara
    Ciniselli, Chiara Maura
    Wyrich, Ralf
    Oelmueller, Uwe
    Kubista, Mikael
    Lindahl, Torbjorn
    Lonneborg, Anders
    Rian, Edith
    [J]. PLOS ONE, 2014, 9 (11):