Analysis of oxygen-18 in orthophosphate by electrospray ionisation mass spectrometry

被引:11
|
作者
Alvarez, R
Evans, LA
Milham, P
Wilson, MA
机构
[1] Univ Technol Sydney, Dept Chem Mat & Forens Sci, Sydney, NSW 2007, Australia
[2] New S Wales Dept Agr, Orange, NSW 2800, Australia
基金
澳大利亚研究理事会;
关键词
orthophosphate; metaphosphate; electrospray ionisation mass spectrometry (ESI-MS); oxygen-18; isotope;
D O I
10.1016/S1387-3806(00)00297-9
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Isotope distributions in phosphate are useful measurements in geochemical systems since they give information on origin and environmental oxygen exchange processes. It is often necessary to perform measurements rapidly at the parts per million level on milligram quantities of sample. However, current methodologies require conversion to gas and/or time consuming multiple precipitation steps or insensitive nuclear magnetic resonance (NMR) techniques. in the electrospray method developed here, lengthy analyses requiring precipitation of phosphate are unnecessary. Moreover, there is no requirement for conversion to a simple gas and indirect evaluation. Accuracy is demonstrated by good agreement with NMR measurements on concentrated laboratory prepared chemical solutions. After dilution, electrospray analyses gave similar results. (C) 2000 Elsevier Science B.V.
引用
收藏
页码:177 / 186
页数:10
相关论文
共 50 条
  • [1] VARIABLES IN OXYGEN-18 ISOTOPIC ANALYSIS BY MASS SPECTROMETRY
    TAYLOR, JW
    CHEN, IJ
    ANALYTICAL CHEMISTRY, 1970, 42 (02) : 224 - &
  • [2] Electrospray as an ionisation method for mass spectrometry
    Dülcks, T
    Juraschek, R
    JOURNAL OF AEROSOL SCIENCE, 1999, 30 (07) : 927 - 943
  • [3] A METHOD FOR DETERMINING OXYGEN-18 CONTENT OF ORTHOPHOSPHATE OR WATER
    FALCONE, AB
    ANALYTICAL BIOCHEMISTRY, 1961, 2 (02) : 147 - &
  • [4] Analysis of the structural heterogeneity of laminarin by electrospray-ionisation-mass spectrometry
    Read, SM
    Currie, G
    Bacic, A
    CARBOHYDRATE RESEARCH, 1996, 281 (02) : 187 - 201
  • [5] The application of electrospray ionisation and tandem mass spectrometry to the analysis of polymer additives
    Jackson, AT
    Buzy, A
    Jennings, KR
    Scrivens, JH
    EUROPEAN MASS SPECTROMETRY, 1996, 2 (2-3): : 115 - 127
  • [6] Chiral recognition of amino acids by electrospray ionisation mass spectrometry/mass spectrometry
    Yao, ZP
    Wan, TSM
    Kwong, KP
    Che, CT
    CHEMICAL COMMUNICATIONS, 1999, (20) : 2119 - 2120
  • [7] Probing phospholipid dynamics by electrospray ionisation mass spectrometry
    Postle, Anthony D.
    Wilton, David C.
    Hunt, Alan N.
    Attard, George S.
    PROGRESS IN LIPID RESEARCH, 2007, 46 (3-4) : 200 - 224
  • [8] Lactolation of β-lactoglobulin monitored by electrospray ionisation mass spectrometry
    Morgan, F
    Bouhallab, S
    Molle, D
    Henry, G
    Maubois, JL
    Leonil, J
    INTERNATIONAL DAIRY JOURNAL, 1998, 8 (02) : 95 - 98
  • [9] Ionic liquids: Solutions for Electrospray Ionisation Mass Spectrometry
    Dyson, Paul J.
    Henderson, Matthew A.
    McIndoe, J. Scott
    IONIC LIQUIDS: FROM KNOWLEDGE TO APPLICATION, 2009, 1030 : 135 - 146
  • [10] Quantification of Gγ- and Aγ-globins by electrospray ionisation mass spectrometry
    Ofori-Acquah, SF
    Green, BN
    Wild, BJ
    Lalloz, MRA
    Layton, DM
    INTERNATIONAL JOURNAL OF MOLECULAR MEDICINE, 1998, 2 (04) : 451 - 453