Inter-reader variability in Alternate Forced Choice studies - art. no. 691711

被引:4
|
作者
Huda, W. [1 ]
Ogden, K. M. [1 ]
Samei, E. [1 ]
Scalzetti, E. M. [1 ]
Lavallee, R. L. [1 ]
Roskopf, M. L. [1 ]
机构
[1] Med Univ S Carolina, Dept Radiol, Charleston, SC 29425 USA
关键词
CT; Alternate Forced Choice; contrast detail curves; inter-reader variability; Rose model; detection performance;
D O I
10.1117/12.770618
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this study, we investigated differences in detection performance for twelve observers who each generated a CT contrast detail curve. An anthropomorphic newborn phantom's abdomen was imaged using a GE Light Speed CT scanner (4-slice). Alternate Forced Choice (AFC) experiments were performed with lesions sizes ranging from 2.5 to 12.5 mm to determine the intensity needed to achieve 92% correct (I-92%). Following training, twelve readers consisting of (2 technologists, 4 college students, 4 medical students, and 2 radiology residents) generated a single contrast detail curve. Eight readers produced approximately linear contrast detail curves while the remaining four readers required a second order polynomial fit because of reduced performance when detecting the largest (i.e., 12.5 mm) lesion. For the three smallest lesions, the coefficient of variation between the twelve readers was similar to 12%, which increases with increasing lesion size to similar to 23% for 12.5 mm lesion size. The ratio of the maximum I-92%, to minimum I-92% values was similar to 1.6 for the smallest lesions, which increased to a factor of similar to 2.1 for the 12.5 mm lesion. Our results show that minimizing inter-reader variability in our AFC experiments could be achieved by eliminating the largest lesion that cause detection problems in one third of observers. The combined experimental data showed that the slope of the contrast detail curve was -0.42, lower than the value of -1.0 predicted by the Rose model, suggesting that the noise texture in CT associated with both quantum mottle and anatomic. structure is an important factor affecting detection of these lesions.
引用
收藏
页码:91711 / 91711
页数:11
相关论文
共 50 条
  • [1] INTER-READER VARIABILITY OF THE MANUAL DIFFERENTIAL LEUKOCYTE COUNT IN NEWBORNS
    SCHELONKA, RL
    YODER, BA
    HALL, RB
    TRIPPETT, T
    [J]. PEDIATRIC RESEARCH, 1994, 35 (04) : A169 - A169
  • [2] Inter-Reader Variability of Volumetric Subsolid Pulmonary Nodule Radiomic Features
    Azour, Lea
    Moore, William H.
    O'Donnell, Thomas
    Truong, Mylene T.
    Babb, James
    Niu, Bowen
    Wimmer, Andreas
    Kiumehr, Saman
    Ko, Jane P.
    [J]. ACADEMIC RADIOLOGY, 2022, 29 : S98 - S107
  • [3] International study on inter-reader variability for circulating tumor cells in breast cancer
    Michail Ignatiadis
    Sabine Riethdorf
    François-Clement Bidard
    Isabelle Vaucher
    Mustapha Khazour
    Françoise Rothé
    Jessica Metallo
    Ghizlane Rouas
    Rachel E Payne
    Raoul Charles Coombes
    Ingrid Teufel
    Ulrich Andergassen
    Stella Apostolaki
    Eleni Politaki
    Dimitris Mavroudis
    Silvia Bessi
    Marta Pestrin
    Angelo Di Leo
    Michael Campion
    Monica Reinholz
    Edith Perez
    Martine Piccart
    Elin Borgen
    Bjorn Naume
    Jose Jimenez
    Claudia Monica Aura
    Laura Zorzino
    Maria Cristina Cassatella
    Maria Teresa Sandri
    Bianca Mostert
    Stefan Sleijfer
    Jaco Kraan
    Wolfgang Janni
    Tanja Fehm
    Brigitte Rack
    Leon Terstappen
    Madeline Repollet
    Jean-Yves Pierga
    Craig Miller
    Christos Sotiriou
    Stefan Michiels
    Klaus Pantel
    [J]. Breast Cancer Research, 16
  • [4] International study on inter-reader variability for circulating tumor cells in breast cancer
    Ignatiadis, Michail
    Riethdorf, Sabine
    Bidard, Franois-Clement
    Vaucher, Isabelle
    Khazour, Mustapha
    Roth, Franoise
    Metallo, Jessica
    Rouas, Ghizlane
    Payne, Rachel E.
    Coombes, Raoul Charles
    Teufel, Ingrid
    Andergassen, Ulrich
    Apostolaki, Stella
    Politaki, Eleni
    Mavroudis, Dimitris
    Bessi, Silvia
    Pestrin, Marta
    Di Leo, Angelo
    Campion, Michael
    Reinholz, Monica
    Perez, Edith
    Piccart, Martine
    Borgen, Elin
    Naume, Bjorn
    Jimenez, Jose
    Aura, Claudia Monica
    Zorzino, Laura
    Cassatella, Maria Cristina
    Sandri, Maria Teresa
    Mostert, Bianca
    Sleijfer, Stefan
    Kraan, Jaco
    Janni, Wolfgang
    Fehm, Tanja
    Rack, Brigitte
    Terstappen, Leon
    Repollet, Madeline
    Pierga, Jean-Yves
    Miller, Craig
    Sotiriou, Christos
    Michiels, Stefan
    Pantel, Klaus
    [J]. BREAST CANCER RESEARCH, 2014, 16 (02)
  • [5] Inter-reader variability of imaging biomarkers for therapeutic response in pancreatic ductal adenocarcinoma
    Heiselman, Jon Stanley
    Horvat, Natally
    Agridag-Upcinar, Burcin
    Yildirim, Onur
    Ecker, Brett Logan
    O'Reilly, Eileen Mary
    Drebin, Jeffrey A.
    Balachandran, Vinod P.
    Kingham, T. Peter
    D'Angelica, Michael Ian
    Soares, Kevin
    Do, Richard K. G.
    El Homsi, Maria
    Jarnagin, William R.
    Wei, Alice Chia-Chi
    Chakraborty, Jayasree
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2024, 42 (3_SUPPL) : 700 - 700
  • [6] Impact of inter-reader contouring variability on textural radiomics of colorectal liver metastases
    Rizzetto, Francesco
    Calderoni, Francesca
    De Mattia, Cristina
    Defeudis, Arianna
    Giannini, Valentina
    Mazzetti, Simone
    Vassallo, Lorenzo
    Ghezzi, Silvia
    Sartore-Bianchi, Andrea
    Marsoni, Silvia
    Siena, Salvatore
    Regge, Daniele
    Torresin, Alberto
    Vanzulli, Angelo
    [J]. EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)
  • [7] Inter-reader variability and reproducibility of the PI-QUAL score in a multicentre setting
    Fleming, Hannah
    Dias, Adriano Basso
    Talbot, Nancy
    Li, Xuan
    Corr, Kateri
    Haider, Masoom A.
    Ghai, Sangeet
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2023, 168
  • [8] Impact of inter-reader contouring variability on textural radiomics of colorectal liver metastases
    Francesco Rizzetto
    Francesca Calderoni
    Cristina De Mattia
    Arianna Defeudis
    Valentina Giannini
    Simone Mazzetti
    Lorenzo Vassallo
    Silvia Ghezzi
    Andrea Sartore-Bianchi
    Silvia Marsoni
    Salvatore Siena
    Daniele Regge
    Alberto Torresin
    Angelo Vanzulli
    [J]. European Radiology Experimental, 4
  • [9] PNEUMOCONIOSIS - INTER-READER VARIABILITY IN CLASSIFICATION OF TYPE OF SMALL OPACITIES IN CHEST ROENTGENOGRAM
    AMANDUS, HE
    PENDERGRASS, EP
    DENNIS, JM
    MORGAN, WKC
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1974, 122 (04) : 740 - 743
  • [10] Effect of inter-reader variability on outcomes in studies using carotid intima media thickness quantified by carotid ultrasonography
    Joseph A. C. Delaney
    Rebecca Scherzer
    Joseph Polak
    Mary Lou Biggs
    Richard Kronmal
    Haiying Chen
    Stephen Sidney
    Carl Grunfeld
    [J]. European Journal of Epidemiology, 2010, 25 : 385 - 392