Time and Frequency Characteristics of Very Fast Transient Overvoltage in Ultra High Voltage Substation

被引:23
|
作者
Ma, Guo-Ming [1 ,2 ]
Li, Cheng-Rong [1 ,2 ]
Li, Xiong [1 ,2 ]
Zhou, Hong-Yang [1 ,2 ]
Chen, Wei-Jiang [3 ]
Wang, Hao [4 ]
Li, Zhi-bing [4 ]
机构
[1] North China Elect Power Univ, Beijing Key Lab High Voltage, Key Lab Alternate Elect Power Syst Renewable Ener, 2 Beinong Rd, Beijing 102206, Peoples R China
[2] North China Elect Power Univ, EMC, 2 Beinong Rd, Beijing 102206, Peoples R China
[3] State Grid Corp China, Ultra High Voltage Dept, 86 West Changan St, Beijing 100031, Peoples R China
[4] China Elect Power Res Inst, High Voltage Res Dept, 15 Xiaoying East Rd, Beijing 100192, Peoples R China
关键词
GIS; VFTO; measurement; 1000 kV substation; S transform; time and frequency characteristics; GAS-INSULATED SWITCHGEAR; KV GIS; DISCONNECTOR; VFTO;
D O I
10.1109/TDEI.2017.005687
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Most work about the measurement of very fast transient overvoltage (VFTO) was carried out in the laboratory and test base. Because of the different GIS arrangement and power capacity, the time and frequency characteristics of VFTO in ultra high voltage (UHV) substation could be different with that obtained in the laboratory and test base. A series of VFTO measurements were carried out in two 1100 kV GIS substations to investigate the characteristics of on-site VFTO. The port-hole sensor based on surface-mounted device was chosen to measure the VFTO for its reliability and wide band-width. The whole measurement system was introduced and the schematic layout of each experiment was given. Measurement results of different switch conditions and measure points were presented for comprehensive understanding of the VFTO characteristics on site. The results indicated that the striking number during one operation was 16 (closing) and 14 (opening), similar to that obtained from test base result. Besides, single strike with front time 5.3 ns and voltage steepness 186.1 kV/ns was recorded, and the steepness was relatively higher than that gained in the test base. Moreover, the spectral analysis based on S transform was investigated to get the duration of different frequency components of VFTO waveform. Compared with the data obtained from the test base, the high frequency components of VFTO were reduced, while the lower frequency components lasted longer. The results provided references for the investigation of the electromagnetic interfere, the insulation coordination, and VFTO mitigation methods.
引用
收藏
页码:2459 / 2468
页数:10
相关论文
共 50 条
  • [1] Calibration of very fast transient overvoltage measurement system for ultra high voltage gas insulated switchgear
    Yue, Gongchang
    Liu, Weidong
    Chen, Weijiang
    Guan, Yonggang
    Li, Zhibing
    Gaodianya Jishu/High Voltage Engineering, 2012, 38 (02): : 342 - 349
  • [2] Study on Time-frequency Analysis Method of Very Fast Transient Overvoltage
    Li, Shuai
    Liu, Shiming
    Huang, Qiyan
    Fu, Chuanshun
    NINTH INTERNATIONAL CONFERENCE ON GRAPHIC AND IMAGE PROCESSING (ICGIP 2017), 2018, 10615
  • [3] Insulation characteristics of GIS spacer for very fast transient overvoltage
    Okabe, S
    Koto, M
    Endo, F
    Kobayashi, K
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (01) : 210 - 218
  • [4] Differentiating/integrating system for the measurement of very fast transient overvoltage in gas-insulated substation
    Guangdong Power Test and Research, Inst, Guangzhou, China
    Zhongguo Dianji Gongcheng Xuebao, 5 (59-61, 29):
  • [5] Simulation and Test Study on Very Fast Transient Overvoltage in 1000kV GIS Substation
    Han, Bin
    Lin, Jiming
    Ban, Liangeng
    Wang, Hao
    Li, Zhibing
    Xiang, Zutao
    2017 2ND ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2017), 2017, 199
  • [6] Testing Technology on Very Fast Transient Overvoltage in 500kV HGIS Intelligent Substation
    Liu He
    Sun You-qun
    Lie Jian-ping
    Yan Hao
    Zhang Yi-yun
    Zhao Chun-ming
    PROCEEDINGS OF THE 2012 SECOND INTERNATIONAL CONFERENCE ON INSTRUMENTATION & MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC 2012), 2012, : 363 - 366
  • [7] Study on Very Fast Transient Overvoltage Characteristics of Gas-Insulated Switchgear Substation Based on Hybrid Reactive Power Compensation
    Wen, Caiquan
    Yang, Zheng
    Lu, Yitao
    Huang, Yongfeng
    Lin, Hanliang
    Zhang, Zhiyuan
    Chen, Taiyu
    Liu, Yingnan
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2022, 2022
  • [8] Research on Ultra-Fast Transient Overvoltage Characteristics of Electric Locomotive
    Guo, Yike
    Tian, Fuqiang
    Liu, Hongqi
    Yin, Yufeng
    Applied Sciences (Switzerland), 2024, 14 (20):
  • [9] 3-MV Compact Very Fast Transient Overvoltage Generator for Testing Ultra-High-Voltage Gas-Insulated Switchgear
    Wen, Tao
    Zhang, Qiaogen
    Guo, Can
    Liu, Xuandong
    Pang, Lei
    Zhao, Junping
    Yin, Yu
    Shi, Weidong
    Chen, Weijiang
    Tan, Xiangyu
    IEEE ELECTRICAL INSULATION MAGAZINE, 2014, 30 (06) : 26 - 33
  • [10] Simulation Studies on Very Fast Transient Overvoltage
    He, Baina
    Zhao, Yunwei
    Huang, Guichun
    Hu, Yuanchao
    An, Yunzhu
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,