The influence of cortical end-plate on broadband ultrasound attenuation measurements at the human calcaneus using scanning confocal ultrasound

被引:29
|
作者
Xia, Y [1 ]
Lin, W [1 ]
Qin, YX [1 ]
机构
[1] SUNY Stony Brook, Dept Biomed Engn, Stony Brook, NY 11794 USA
来源
关键词
D O I
10.1121/1.1979428
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Quantitative ultrasound (QUS) assessment, including broadband ultrasound attenuation (BUA), is an efficient technique for assessing bone quality in various statuses, e.g., osteoporosis. While assessing trabecular bone loss is essential to bone quality, the existence of cortical bone can substantially reduce the accuracy of BUA measurement. In this study, we developed an approach to quantify the influence of the cortical end-plate in the QUS on 18 cadaver calcanei using both analytical and experimental analyses. A simplified cortical-trabecular-cortical sandwich model has been developed for simulation of wave propagations. Results show that the cortical end-plate has a significant effect on BUA (yielding 8.5 +/- 3.6 dB/MHz in cortical bone alone), approximately 15% of the BUA value over the whole bone BUA measurement (54.1 +/- 20.1 dB/MHz). The phenomenon has been predicted by the developed analytical model with a high correlation (r(2)=0.63,p < 0.0001). The data have suggested that the mechanism of the BUA attributed to the cortical end-plate is primarily due to the ultrasonic wave transmission and reflection within the cortical layers. Therefore, the influence of the cortical end-plate in BUA can be quantified and incorporated into the QUS assessment for bone quality, which may provide insight into BUA measurement for accurate diagnosis of bone diseases. (c) 2005 Acoustical Society of America.
引用
收藏
页码:1801 / 1807
页数:7
相关论文
共 13 条
  • [1] The influence of cortical end-plate on broadband ultrasound attenuation measurements at the human calcaneus using scanning confocal ultrasound
    Xia, Yi
    Lin, Wei
    Qin, Yi-Xian
    [J]. Journal of the Acoustical Society of America, 2005, 118 (3 I): : 1801 - 1807
  • [2] Broadband ultrasound attenuation at the calcaneus measured using a new contact ultrasound unit
    Fauchet, M
    Andrieux, P
    Roux, C
    Sebert, JL
    [J]. REVUE DU RHUMATISME, 1998, 65 (04): : 257 - 266
  • [3] Factors affecting broadband ultrasound attenuation results of the calcaneus using a gel-coupled quantitative ultrasound scanning system
    Cheng, S
    Fan, B
    Wang, L
    Fuerst, T
    Lian, M
    Njeh, C
    He, Y
    Kern, M
    Lappin, M
    Tylavsky, F
    Casal, D
    Harris, S
    Genant, HK
    [J]. OSTEOPOROSIS INTERNATIONAL, 1999, 10 (06) : 495 - 504
  • [4] Factors Affecting Broadband Ultrasound Attenuation Results of the Calcaneus Using a Gel-Coupled Quantitative Ultrasound Scanning System
    S. Cheng
    B. Fan
    L. Wang
    T. Fuerst
    M. Lian
    C. Njeh
    Y. He
    M. Kern
    M. Lappin
    F. Tylavsky
    D. Casal
    S. Harris
    H. K. Genant
    [J]. Osteoporosis International, 1999, 10 : 495 - 504
  • [5] Assessment of bone quantity and quality in human cadaver calcaneus using scanning confocal ultrasound and DEXA measurements.
    Qin, Y
    Xia, Y
    Lin, W
    Chadha, A
    Gruber, B
    Rubin, C
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2002, 17 : S422 - S422
  • [6] Assessment of the relationship between broadband ultrasound attenuation and bone mineral density at the calcaneus using BUA imaging and DXA
    C. Chappard
    P. Laugier
    B. Fournier
    C. Roux
    G. Berger
    [J]. Osteoporosis International, 1997, 7 : 316 - 322
  • [7] Assessment of the relationship between broadband ultrasound attenuation and bone mineral density at the calcaneus using BUA imaging and DXA
    Chappard, C
    Laugier, P
    Fournier, B
    Roux, C
    Berger, G
    [J]. OSTEOPOROSIS INTERNATIONAL, 1997, 7 (04) : 316 - 322
  • [8] The influence of cortical end plate upon ultrasound transit time spectroscopy estimated bone assessment
    Al-Qahtani, Saeed Mueed
    [J]. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2024, 17 (03)
  • [9] Spectral ratio method to estimate broadband ultrasound attenuation of cortical bones in vitro using multiple reflections
    Zheng, Rui
    Le, Lawrence H.
    Sacchi, Mauricio D.
    Ta, Dean
    Lou, Edmond
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (19): : 5855 - 5869
  • [10] An Introduction to Measurements of Human Cortical Bone Elasticity using Resonant Ultrasound Spectroscopy
    Cai, Xiran
    Bernard, Simon
    Laugier, Pascal
    Grimal, Quentin
    Schneider, Johannes
    Varga, Peter
    Raum, Kay
    [J]. 2015 6TH EUROPEAN SYMPOSIUM ON ULTRASONIC CHARACTERIZATION OF BONE (ESUCB), 2015,