Effect of installation angle of fins on melting characteristics of annular unit for latent heat thermal energy storage

被引:166
|
作者
Yuan, Yanping [1 ]
Cao, Xiaoling [1 ]
Xiang, Bo [1 ]
Du, Yanxia [2 ]
机构
[1] Southwest Jiaotong Univ, Sch Mech Engn, Chengdu 610031, Peoples R China
[2] China Aerodynam Res & Dev Ctr, State Key Lab Aerodynam, Mianyang 621000, Peoples R China
基金
中国国家自然科学基金;
关键词
Latent heat thermal energy storage (LHTES) unit; Heat transfer enhancement; Installation angle of fins; Numerical simulation; PHASE-CHANGE MATERIAL; CHANGE MATERIAL PCM; STEARIC-ACID; CONDUCTIVITY ENHANCEMENT; PERFORMANCE ENHANCEMENT; GRAPHITE COMPOSITE; SHELL; SYSTEM; PARAFFIN; SOLIDIFICATION;
D O I
10.1016/j.solener.2016.07.014
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Latent heat thermal energy storage (LHTES) technology can solve the problem of a mismatch between energy supply and demand in time, space and intensity and thus has become a research on focus in energy and environmental protection. The low thermal conductivity of phase change materials (PCMs) is the primary bottleneck of the popularization application of LHTES technology. An effective way to solve this problem is adding fins into the PCM container to enhance heat transfer, there has been no report on the effect of the installation location of fins on the heat transfer characteristics of the PCM in a LHTES unit. To study the effect of fins installed at different locations on the heat transfer, this work have investigated the melting characteristics of PCM in an annular with different installation angle of fins (theta) via a numerical simulation method, which is based on an enthalpy-porous medium model. In addition, the numerical calculation results are verified via experimentation. On this basis, the melting processes of the PCM in horizontal, annular units with fins installed at five different values of theta under three fixed wall temperature conditions (60, 70, and 80 degrees C) have been simulated. The simulation results have been compared to those of the unit without fins. The results show that although fins inhibit natural convection, the addition of fins can lead to an increase in the melting rate and a decrease in the melting time due to an increase in the total amount of heat exchanged. Considering the entire melting process, the melting rate of the PCM in the unit with fins installed at theta = 0 degrees is maximum. When theta reaches 45, the further increase of theta has no marked impact on the melting rate of the PCM in the unit. Based on the trend of the change of the mean Nusselt number with the Fourier number (Fo), the heat transfer of the melting process of the PCM is divided into four stages. Additionally, the dimensionless criterion relationship between the melting fraction (f) and SteFoRa(1/6) when theta = 0 degrees is fitted as f = 0.24X(3) - 1.13X(2) + 1.82X, where X = SteFoRa(1/6). (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:365 / 378
页数:14
相关论文
共 50 条
  • [1] An experimental study on the effect of annular and radial fins on thermal performance of a latent heat thermal energy storage unit
    Tiari, Saeed
    Hockins, Addison
    [J]. JOURNAL OF ENERGY STORAGE, 2021, 44
  • [2] Assessment on the effect of longitudinal fins upon melting process in a latent heat thermal energy storage unit
    Ao, Ci
    Yan, Suying
    Zhao, Long
    Wu, Yuting
    [J]. JOURNAL OF ENERGY STORAGE, 2023, 59
  • [3] Melting behavior of the latent heat thermal energy storage unit with fins and graded metal foam
    Yang, Chao
    Xu, Yang
    Cai, Xiao
    Zheng, Zhang-Jing
    [J]. APPLIED THERMAL ENGINEERING, 2021, 198
  • [4] Comparison of Thermal Performance between Annular Fins and Longitudinal Fins in Latent Heat Storage Unit
    ZHU Yuxi
    QIU Yan
    [J]. Journal of Thermal Science, 2023, 32 (03) : 1227 - 1238
  • [5] Comparison of Thermal Performance between Annular Fins and Longitudinal Fins in Latent Heat Storage Unit
    Zhu, Yuxi
    Qiu, Yan
    [J]. JOURNAL OF THERMAL SCIENCE, 2023, 32 (03) : 1227 - 1238
  • [6] Comparison of Thermal Performance between Annular Fins and Longitudinal Fins in Latent Heat Storage Unit
    Yuxi Zhu
    Yan Qiu
    [J]. Journal of Thermal Science, 2023, 32 : 1227 - 1238
  • [7] Thermal performance of a shell-and-tube latent heat thermal energy storage unit: Role of annular fins
    Yang, Xiaohu
    Lu, Zhao
    Bai, Qingsong
    Zhang, Qunli
    Jin, Liwen
    Yan, Jinyue
    [J]. APPLIED ENERGY, 2017, 202 : 558 - 570
  • [8] Thermal and fluid characteristics of a latent heat thermal energy storage unit
    Yang, Xiaohu
    Li, Yang
    Lu, Zhao
    Zhang, Lianying
    Zhang, Qunli
    Jin, Liwen
    [J]. CLEAN ENERGY FOR CLEAN CITY: CUE 2016 - APPLIED ENERGY SYMPOSIUM AND FORUM: LOW-CARBON CITIES AND URBAN ENERGY SYSTEMS, 2016, 104 : 425 - 430
  • [9] EXPERIMENTAL INVESTIGATION OF LATENT HEAT THERMAL ENERGY STORAGE SYSTEM ENHANCED BY ANNULAR AND RADIAL FINS
    Tiari, Saeed
    Hockins, Addison
    Moretti, Samantha
    [J]. PROCEEDINGS OF THE ASME 2021 15TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY (ES2021), 2021,
  • [10] Biomimetic optimized vertically aligned annular fins for fast latent heat thermal energy storage
    Liu, Xianglei
    Qin, Xinliang
    Tian, Yang
    Luo, Qingyang
    Yao, Haichen
    Wang, Jianguo
    Dang, Chunzhuo
    Xu, Qiao
    Lv, Shushan
    Xuan, Yimin
    [J]. APPLIED ENERGY, 2023, 347