Feasibility and safety of arthroscopic medial glenohumeral ligament and subscapularis tendon repair with knotless anchors: A cadaveric study in dogs

被引:6
|
作者
Penelas, Alexandra [1 ]
Gutbrod, Andreas [1 ]
Kuhn, Karolin [2 ]
Pozzi, Antonio [1 ]
机构
[1] Univ Zurich, Vetsuisse Fac, Small Anim Dept, Clin Small Anim Surg, Winterthurerstr 260, CH-8057 Zurich, Switzerland
[2] Univ Zurich, Vetsuisse Fac, Small Anim Dept, Clin Diagnost Imaging, Zurich, Switzerland
关键词
SHOULDER INSTABILITY; THERMAL CAPSULORRHAPHY; CANINE SHOULDER; SUTURE ANCHORS; STABILITY; INSERTION; JOINT; STABILIZATION; MANAGEMENT; DIAGNOSIS;
D O I
10.1111/vsu.12929
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective: To test the feasibility and safety of an arthroscopic imbrication of the medial glenohumeral ligament (MGHL) and the subscapularis tendon with knotless anchors in dogs. Study design: Cadaveric study. Sample population: Ten limbs. Methods: Cranial and caudal arms of the MGHL were imbricated with a 2.9- or a 2.4-mm knotless anchor. A horizontal mattress suture secured with a 3.5-mm knotless anchor was used to imbricate the subscapularis tendon. Computed tomography measurements included (1) the bone stock around the anchors, (2) the angle between the anchor and the joint surface (insertion angle), and (3) the angle formed by lines tangent to the cortices of the bones (safety angle). Limbs were dissected to assess the position of anchors. Safety and insertion angles and bone stock were compared among anchors with a Kruskal-Wallis test (P<.05). Results: Surgical repairs were achieved in all limbs, with only 2 of 30 anchors incorrectly placed, both in the glenoid. The safety angle of the humeral anchor (HA; median, 898) was greater than that of the cranial glenoid anchor (CrGA; P=.0017) and the caudal glenoid anchor (CdGA; P<.001). The insertion angle of the HA (median, 688) was also greater than that of the other anchors (P<.001 and P=.001). The insertion angle of the CrGA (median, 268) was greater (P=.0191) than that of the CdGA (median, 78). All anchors were inserted at the MGHL and subscapularis footprint. Conclusion: Arthroscopic imbrication of MGHL and subscapularis tendon was feasible. HA were safer to place than glenoid anchors.
引用
收藏
页码:817 / 826
页数:10
相关论文
共 50 条
  • [1] Feasibility and safety of arthroscopic medial glenohumeral ligament and subscapularis tendon repair with knotless anchors: A cadaveric study in dogs (vol 47, pg 817, 2018)
    Penelas, A.
    Gutbrod, A.
    Kuhn, K.
    Pozzi, A.
    VETERINARY SURGERY, 2020, 49 (02) : 409 - 409
  • [2] Knotless Arthroscopic Repair of Subscapularis Tendon Tears Using Looped Suture
    Gilmer, Brian B.
    Crall, Timothy S.
    Guttmann, Dan
    ARTHROSCOPY TECHNIQUES, 2015, 4 (03): : E267 - E271
  • [3] Arthroscopic Medial Meniscus Posterior Root Repair with Centralization Using Knotless Suture Anchors
    Wu, Thomas Y.
    ARTHROSCOPY TECHNIQUES, 2022, 11 (04): : E661 - E668
  • [4] Ultrasonographic approach to visualize the medial shoulder compartment and diagnose medial glenohumeral ligament and subscapularis lesions in dogs
    Porter, Ian
    Miller, Allison
    Jennings, Carol
    Frye, Christopher
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2025, 263 (03):
  • [5] Arthroscopic single portal-single row knotless repair of subscapularis tendon tear: Technical note
    Chillemi, Claudio
    Carli, Stefano
    Paolicelli, Domenico
    Carnevali, Cristina
    JOURNAL OF ISAKOS JOINT DISORDERS & ORTHOPAEDIC SPORTS MEDICINE, 2022, 7 (05) : 142 - 147
  • [6] Biomechanical analysis of medial patellofemoral ligament reconstruction: FiberTape® with knotless anchors versus a semitendinosus tendon autograft with soft anchors
    Tsushima, Takahiro
    Tsukada, Harehiko
    Sasaki, Shizuka
    Naraoka, Takuya
    Yamamoto, Yuji
    Tsuda, Eiichi
    Ishibashi, Yasuyuki
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2019, 24 (04) : 663 - 667
  • [7] Arthroscopic Knotless Repair of Complete Full-Thickness Tears of the Subscapularis Tendon Through a Single Portal
    Ek, Eugene T.
    Perret, Michael C.
    Borbas, Paul
    ARTHROSCOPY TECHNIQUES, 2020, 9 (04): : E439 - E443
  • [8] Arthroscopic Single Portal, Single Anchor Knotless Subscapularis Repair with Concomitant Tenodesis of the Long Head of the Biceps Tendon
    Kim, Joo Yeon
    Park, Hee-Yon
    Del Sol, Shane Rayos
    Bryant, Stewart
    Gardner, Brandon
    Chakrabarti, Moyukh O.
    Perinovic, Steven
    McGahan, Patrick J.
    Chen, James L.
    ARTHROSCOPY TECHNIQUES, 2021, 10 (04): : E1117 - E1123
  • [9] Arthroscopic autograft reconstruction of the inferior glenohumeral ligament: Exploration of technical feasibility in cadaveric shoulder specimens
    Bouaicha, Samy
    Moor, Beat K.
    INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2013, 7 (01): : 32 - 36
  • [10] Medial Patellofemoral Ligament Reconstruction Using Gracilis Tendon Graft and "All Suture" Knotless Anchors for Patellar Fixation
    Monaco, Edoardo
    Criseo, Natale
    Annibaldi, Alessandro
    Carrozzo, Alessandro
    Pagnotta, Susanna M.
    Cantagalli, Matteo Romano
    Orlandi, Pierfrancesco
    Daggett, Matthew
    ARTHROSCOPY TECHNIQUES, 2023, 12 (12): : e2329 - e2334