Simulation of Control for Without Wind Speedometer Grid-connected Doubly-fed Induction Generator

被引:0
|
作者
Gao, Yang [1 ]
Ai, Qian [1 ]
Muhammad, Yousif [1 ]
Gao, Hailin [2 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Elect Engn, Shanghai 200240, Peoples R China
[2] Henan Polytech Inst, Nanyang 473009, Henan, Peoples R China
关键词
Doubly-fed induction generator; Without wind speedometer; Rotational speed tracking; Power decoupling;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, the fundamental strategy for controlling the grid-connected doubly-fed induction wind power generation system is taken under deliberation. In varying wind speed, according to the maximum power point tracking control theory, the fuzzy controller is premeditated to reinstate the wind speedometer to track the optimum generator speed based on the generator output power error and rotation speed error. The wind turbine can contrive to operate at the optimal tip speed ratio to ensure the maximum wind energy performance coefficient, avoiding the effects of turbulence on wind speed measurement. Finally, the wind power system is built to demonstrate the feasibility of control strategy.
引用
收藏
页码:442 / 446
页数:5
相关论文
共 50 条
  • [1] Modeling and Control Strategy of Wind Energy Conversion System with Grid-Connected Doubly-Fed Induction Generator
    Chhipa, Abrar Ahmed
    Chakrabarti, Prasun
    Bolshev, Vadim
    Chakrabarti, Tulika
    Samarin, Gennady
    Vasilyev, Alexey N.
    Ghosh, Sandeep
    Kudryavtsev, Alexander
    [J]. ENERGIES, 2022, 15 (18)
  • [2] Decoupled control of active and reactive power for a grid-connected doubly-fed induction generator
    Guo, Jiahu
    Cai, Xu
    Gong, Youming
    [J]. 2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 2620 - 2625
  • [3] The Steady-State Interaction of a Grid-Connected Doubly-Fed Induction Generator and the Wind Turbine
    Aganah, Kennedy Adinbo
    Pokharel, Bijaya
    Ojo, Olorunfemi
    [J]. 2011 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2011, : 2657 - 2663
  • [4] Adaptive Backstepping Control of Grid-Connected Doubly-Fed Induction Generator during Grid Voltage Dip
    Adekanle, Oluwaseun
    Guisser, M.
    Abdelmounim, E.
    Aboulfatah, M.
    [J]. PROCEEDINGS OF 2017 INTERNATIONAL CONFERENCE ON ELECTRICAL AND INFORMATION TECHNOLOGIES (ICEIT 2017), 2017,
  • [5] An Analytical method for detecting instability in grid-connected doubly-fed induction generator
    Nasab, Mohammad Rajabi
    Yaghobi, Hamid
    [J]. IET RENEWABLE POWER GENERATION, 2021, 15 (04) : 778 - 793
  • [6] Predictive control of a doubly-fed induction generator connected to an isolated grid
    Patin, Nicolas
    Naouar, Wissem
    Monmasson, Eric
    Louis, Jean-Paul
    [J]. IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11, 2006, : 3129 - +
  • [7] Intelligent Control of Grid Connected Unified Doubly-Fed Induction Generator
    Singh, Bharat
    Kyriakides, Elias
    Singh, Sri Niwas
    [J]. IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [8] Research on Grid-Connected Control of Doubly-Fed Wind Power Generation
    Zhang, Lijun
    Lin, Xianqi
    Zhang, Jiaming
    Hou, Yunchang
    [J]. 2017 9TH INTERNATIONAL CONFERENCE ON MODELLING, IDENTIFICATION AND CONTROL (ICMIC 2017), 2017, : 406 - 411
  • [9] Design of a Nonlinear Robust Adaptive Controller for a Grid-Connected Doubly-Fed Induction Generator Wind Turbine
    Okou, Francis A.
    Akhrif, Ouassima
    Tarbouchi, Mohammed
    [J]. 18TH MEDITERRANEAN CONFERENCE ON CONTROL AND AUTOMATION, 2010, : 1603 - 1608
  • [10] A Synergetic Control Approach to Grid-Connected, Wind-Turbine Doubly-Fed Induction Generators
    Yu, Xunwei
    Jiang, Zhenhua
    Zhang, Yu
    [J]. 2008 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-10, 2008, : 2070 - 2076