Loaned self-measurement equipment model compared with ambulatory blood pressure monitoring

被引:4
|
作者
César, CV
Victoria, PR
Rogelio, TS
机构
[1] Univ Guadalajara, Hosp Civil Juan L Menchaca, Dept Internal Med, Guadalajara 44430, Jalisco, Mexico
[2] Univ Guadalajara, Hlth Sci Ctr, Dept Physiol, Div Basic Sci, Guadalajara 44430, Jalisco, Mexico
关键词
hypertension diagnosis; ambulatory blood pressure; home blood pressure;
D O I
10.1097/00126097-200304000-00002
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective To compare the correspondence between the loaned self-measurement equipment model (LSEM), 24 h awake ambulatory blood pressure monitoring (ABPM) and clinic blood pressure (CBP). Design A cross-sectional study was carried out involving 90 hypertensive and normotensive subjects. Methods We used a variation of home measurement, the loaned self-measurement equipment model (LSEM), that consisted of lending a number of sphygmomanometers, the property of the clinic, to patients for 3-day periods. The correspondence of results from LSEM was measured against the difference between the two averages, the correlation coefficients and the average unweighted absolute differences. Results The average difference between CBP and ABPM was 6.1/2.5 mmHg (P<0.001, r = 0.54/0.63). Between CBP and LSEM, it was 6.6/1.4 mmHg (P<0.001 / 0.08, r = 0.52/ 0.63), and between the ABPM and LSEM 0.5/ - 1.0 mmHg (P = 0.70/0.14, r = 0.71/0.75). The average unweighted absolute differences between LSEM and ABPM readings were 5.5 and 1.5 mmHg for systolic and diastolic blood pressure, respectively, whereas the average difference between CBP and ABPM means was much higher, at 6.8 mmHg for systolic and 2.7 mmHg for diastolic pressure. Agreement in the diagnosis of systolic hypertension between LSEM and ABPM was found in 78.8% of the individuals, and of diastolic hypertension in 76.7%. Conclusion Blood pressure readings taken using LSEM have a better correspondence than CBP in predicting the awake ABPM value, although the disagreement in terms of diagnosing hypertension should be noted. (C) 2003 Lippincott Williams Wilkins.
引用
收藏
页码:63 / 70
页数:8
相关论文
共 50 条
  • [1] Reproducibility and cost of blood pressure self-measurement using the 'Loaned Self-measurement Equipment Model'
    Calvo-Vargas, C
    Rios, VP
    Troyo-Sanromán, R
    Grover-Paez, F
    [J]. BLOOD PRESSURE MONITORING, 2001, 6 (05) : 225 - 232
  • [2] Arterial stiffness and blood pressure self-measurement with loaned equipment
    Calvo-Vargas, C
    Padilla-Rios, V
    Meza-Flores, A
    Vazquez-Linares, G
    Troyo-Sanromán, R
    Cerda, AP
    Asmar, R
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2003, 16 (05) : 375 - 380
  • [3] Usefulness of the loaned self-measurement equipment model in the diagnosis of high blood pressure.
    Calvo-Vargas, CG
    López, AAF
    Parra-Rodriguez, L
    Polanco-Preza, MA
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1999, 12 (04) : 153A - 153A
  • [4] Agreement between home self-measurement and ambulatory monitoring of blood pressure
    Divisón, JA
    Carbayo, J
    Sanchis, C
    Artigao, LM
    [J]. MEDICINA CLINICA, 2001, 116 (19): : 759 - 759
  • [5] Diagnosis of White Coat effect using the loaned self-measurement equipment model
    Calvo-Vargas, CG
    López, AAF
    Parra-Rodríguez, L
    Polanco-Preza, MA
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1999, 12 (04) : 153A - 153A
  • [6] Epidemiology of hypertension based on ambulatory blood pressure monitoring and self-measurement of blood pressure at home
    Imai, Y
    Okubo, T
    Asayama, K
    Metoki, H
    Kikuya, M
    Hashimoto, J
    Ugajin, T
    Totsune, K
    Satohe, H
    [J]. JOURNAL OF HEALTH SCIENCE, 2004, 50 (02) : 113 - 119
  • [7] Self-measurement and ambulatory monitoring of blood pressure:: a subject's chronobiological perspective
    Stinson, SM
    Cornélissen, G
    Scarpelli, PT
    Halberg, F
    [J]. BIOMEDICINE & PHARMACOTHERAPY, 2002, 56 : 333S - 338S
  • [8] Lack of agreement between home self-measurement and ambulatory monitoring of blood pressure
    Eslava, MG
    Barrio, AC
    López, FG
    [J]. MEDICINA CLINICA, 2001, 116 (18): : 719 - 719
  • [9] Correlation of Blood Pressure Variability as Measured By Clinic, Self-measurement at Home, and Ambulatory Blood Pressure Monitoring
    Abellan-Huerta, Jos
    Prieto-Valiente, Luis
    Montoro-Garcia, Silvia
    Abellan-Aleman, Jos
    Soria-Arcos, Federico
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2018, 31 (03) : 305 - 312
  • [10] Ambulatory Blood Pressure Monitoring (ABM) and Blood Pressure Self-Measurement - Possible Causes for different Results
    Hitzenberger, G.
    [J]. JOURNAL FUR HYPERTONIE, 2006, 10 (02): : 7 - 8