Analysis of single cells with capillary electrophoresis electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry

被引:0
|
作者
Hofstadler, SA
Severs, JC
Smith, RD
Swanek, FD
Ewing, AG
机构
[1] PACIFIC NW NATL LAB,ENVIRONM MOL SCI LAB,RICHLAND,WA 99352
[2] PENN STATE UNIV,DEPT CHEM,UNIVERSITY PK,PA 16802
关键词
D O I
10.1002/(SICI)1097-0231(19960610)10:8<919::AID-RCM597>3.0.CO;2-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recent results with on-line capillary electrophoresis (CE) electrospray ionization (ESI) Fourier transform ion cyclotron resonance (FTICR) mass spectrometry suggest that CE/ESI-FTICR can provide a powerful technique for micro-sample analyses owing to the inherent sensitivity of the technique and the enhanced information content derived from high-performance mass measurements. Using micro-sampling methods and ion accumulation techniques based on quadrupolar excitation, we demonstrate that adequate sensitivity exists to characterize the hemoglobin from a single human erythrocyte (approximate to 450 amol). In these studies mass spectra with average mass resolution in excess of 45 000 (FWHM) were obtained for both the alpha- and beta chain of hemoglobin following in-column lysing of a single erythrocyte.
引用
收藏
页码:919 / 922
页数:4
相关论文
共 50 条
  • [1] Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
    Hendrickson, CL
    Emmett, MR
    [J]. ANNUAL REVIEW OF PHYSICAL CHEMISTRY, 1999, 50 : 517 - 536
  • [2] Carbohydrate analysis by desorption electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
    Bereman, Michael S.
    Williams, Taufika Islam
    Muddiman, David C.
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (22) : 8812 - 8815
  • [3] Composition of explosives by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
    Wu, ZG
    Hendrickson, CL
    Rodgers, RP
    Marshall, AG
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (08) : 1879 - 1883
  • [4] Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry at 9.4 tesla
    Senko, MW
    Hendrickson, CL
    White, FM
    Quinn, JP
    Marto, JA
    PasaTolic, L
    Guan, SH
    Marshall, AG
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 212 : 76 - ANYL
  • [5] Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry of multimeric metalloproteins
    Taylor, PK
    Kurtz, DM
    Amster, IJ
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 210 (1-3) : 651 - 663
  • [6] CAPILLARY ELECTROPHORESIS ELECTROSPRAY-IONIZATION FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY FOR DIRECT ANALYSIS OF CELLULAR PROTEINS
    HOFSTADLER, SA
    SWANEK, FD
    GALE, DC
    EWING, AG
    SMITH, RD
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (08) : 1477 - 1480
  • [7] Capillary isoelectric focusing-electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry for protein characterization
    Yang, LY
    Lee, CS
    Hofstadler, SA
    Pasa-Tolic, L
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (15) : 3235 - 3241
  • [8] Fourier transform ion cyclotron resonance mass spectrometry: A celebration of the power of electrospray ionization.
    Marshall, AG
    Hendrickson, CL
    Emmett, MR
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 220 : U98 - U98
  • [9] Lithium Cationization for Petroleum Analysis by Positive Ion Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    Lobodin, Vladislav V.
    Juyal, Priyanka
    McKenna, Amy M.
    Rodgers, Ryan P.
    Marshall, Alan G.
    [J]. ENERGY & FUELS, 2014, 28 (11) : 6841 - 6847
  • [10] Estimating the intermediate precision in petroleum analysis by (±)electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
    Folli, Gabriely S.
    Souza, Lindamara M.
    Araujo, Bruno Q.
    Romao, Wanderson
    Filgueiras, Paulo R.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34