Automatic target localization and verification for on-line image-guided stereotactic body radiotherapy of the spine

被引:5
|
作者
Wang, Congjun
Shin, Almon
Lii, MingFwu
Woo, Shiao
Chang, Eric L.
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
关键词
image-guided; stereotactic; radiotherapy; image registration;
D O I
10.1177/153303460700600306
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To facilitate image-guided stereotactic body radiotherapy (IG-SBRT) of spinal and paraspinal tumors, the authors have developed an on-line image registration system for automated target localization and patient position verification with high precision. When rotations are present in a patient's daily setup position, a setup error of a few millimeters can be introduced in localization of the isocenter by using surrounding bony structures. This setup error not only will deteriorate the dose coverage of the tumor, more importantly it will overdose the spinal cord. To resolve this issue, the image registration program developed by the authors detects translational shifts as well as rotational shifts using 3D CT image registration. Unacceptable rotations were corrected by either repositioning the patient or adjusting the treatment couch that was capable of rotational corrections when such a couch was available for clinical use. One pair of orthogonal digitally reconstructed radiographs (DRR) were generated from the daily pretreatment CT scan to compare with the corresponding DRRs generated from the planning CT scan to confirm the target shift correction. After the patient's position was corrected a pair of orthogonal portal images were taken for final verification. The accuracy of the image registration result was found to be within 0.1 mm on a head and neck phantom. Target shifts of a fraction of a millimeter were readily visible in our DRR comparison and portal image verification. The time needed to complete the image registration and DRR comparison was about 3 minutes. An integrated system that combines a high-speed CT scanner and a linear accelerator was used for imaging and treatment delivery. Application of the program in actual IG-SBRT cases demonstrated that it was accurate, fast, and reliable. It serves as a useful tool for image-guided radiotherapy where high precision of target localization is required.
引用
收藏
页码:187 / 195
页数:9
相关论文
共 50 条
  • [1] Automatic localization of the prostate for on-line image-guided radiotherapy
    Smitsmans, MHP
    Wolthaus, JWH
    Artignan, X
    De Bois, J
    Jaffray, DA
    Lebesque, JV
    Van Herk, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S23 - S23
  • [2] Automatic localization of the prostate for on-line or off-line image-guided radiotherapy
    Smitsmans, MHP
    Wolthaus, JWH
    Artignan, X
    De Bois, J
    Jaffray, DA
    Lebesque, JV
    Van Herk, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (02): : 623 - 635
  • [3] Automation of image registration and verification for image-guided stereotactic body radiotherapy
    Wang, C
    Shiu, A
    Lii, M
    Chang, E
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1943 - 1943
  • [4] Target coverage in image-guided stereotactic body radiotherapy of liver tumors
    Wunderink, Wouter
    Romero, Alejandra Mendez
    Osorio, Eliana M. Vasquez
    De Boer, Hans C. J.
    Brandwijk, Rene P.
    Levendag, Peter C.
    Heijmen, Ben J. M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (01): : 282 - 290
  • [5] A STUDY ON TARGET POSITIONING ERROR AND ITS IMPACT ON DOSE VARIATION IN IMAGE-GUIDED STEREOTACTIC BODY RADIOTHERAPY FOR THE SPINE
    Kim, Siyong
    Jin, Hosang
    Yang, Huey
    Amdur, Robert J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (05): : 1574 - 1579
  • [6] Clinical feasibility of using an epid in cine mode for image-guided verification of stereotactic body radiotherapy
    Berbeco, Ross I.
    Hacker, Fred
    Ionascu, Dan
    Mamon, Harvey J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (01): : 258 - 266
  • [7] Image-Guided Analysis of Target Localization Accuracy in Stereotactic Radiosurgery
    Calvo Ortega, J.
    Casals, J.
    San Jose, S.
    Moragues, S.
    Pozo, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S786 - S786
  • [8] Image-guided Stereotactic Body Radiotherapy in Metastatic Prostate Cancer
    Pasqualetti, Francesco
    Panichi, Marco
    Sainato, Aldo
    Baldaccini, Davide
    Cocuzza, Paola
    Gonnelli, Alessandra
    Montrone, Sabrina
    Molinari, Alessandro
    Barbiero, Sara
    Bruschi, Andrea
    Notini, Elis A.
    Ursino, Stefano
    Mazzotti, Valentina
    Morganti, Riccardo
    Coraggio, Gabriele
    Cantarella, Martina
    Erba, Paola Anna
    Paiar, Fabiola
    [J]. ANTICANCER RESEARCH, 2018, 38 (05) : 3119 - 3122
  • [9] Stereotactic body radiotherapy with image-guided delivery for liver metastasis
    Ricchetti, F.
    Fersino, S.
    Mazzola, R.
    Fiorentino, A.
    Levra, N. Giaj
    Aiello, D.
    Gregucci, F.
    Tebano, U.
    Sicignano, G.
    Naccarato, S.
    Ruggieri, R.
    Alongi, F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S770 - S770
  • [10] Treatment dose verification for image-guided stereotactic radiotherapy of lung cancer
    Wang, L
    Feigenberg, S
    Paskalev, K
    Konski, A
    Xiong, W
    Ma, C
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1941 - 1941