Measurement of atmospheric carbon dioxide and water vapor in built-up urban areas in the Gandhinagar-Ahmedabad region in India using a portable tunable diode laser spectroscopy system
被引:11
|
作者:
Roy, Anirban
论文数: 0引用数: 0
h-index: 0
机构:
Indian Inst Technol Gandhinagar, Elect Engn, Gandhinagar 382355, Gujarat, IndiaIndian Inst Technol Gandhinagar, Elect Engn, Gandhinagar 382355, Gujarat, India
Roy, Anirban
[1
]
Sharma, Neetesh Kumar
论文数: 0引用数: 0
h-index: 0
机构:
Indian Inst Technol Gandhinagar, Elect Engn, Gandhinagar 382355, Gujarat, IndiaIndian Inst Technol Gandhinagar, Elect Engn, Gandhinagar 382355, Gujarat, India
Sharma, Neetesh Kumar
[1
]
Chakraborty, Arup Lal
论文数: 0引用数: 0
h-index: 0
机构:
Indian Inst Technol Gandhinagar, Elect Engn, Gandhinagar 382355, Gujarat, IndiaIndian Inst Technol Gandhinagar, Elect Engn, Gandhinagar 382355, Gujarat, India
This paper reports open-path in situ measurements of atmospheric carbon dioxide at Gandhinagar (23.2156 degrees N, 72.6369 degrees E) and Ahmedabad (23.0225 degrees N, 72.5714 degrees E) in the heavily industrialized state of Gujarat in western India. Calibration-free second harmonic wavelength modulation spectroscopy (2f WMS) is used to carry out accurate and fully automated measurements. The mean values of the mole fraction of carbon dioxide at four locations were 438 ppm, 495 ppm, 550 ppm, and 740 ppm, respectively. These values are much higher than the current global average of 406.67 ppm. A 1 mW, 2004-nm vertical cavity surface-emitting laser is used to selectively interrogate the R16 transition of carbon dioxide at 2003.5 nm (4991.2585 cm(-1)). The 2f WMS signal corresponding to the gas absorption line shape is simulated using spectroscopic parameters available in the HITRAN database and relevant laser parameters that are extracted in situ from non-absorbing spectral wings of the harmonic signals. The mole fraction of carbon dioxide is extracted in real-time by a MATLAB program from least-squares fit of the simulated 2f WMS signal to the corresponding experimentally obtained signal. A 10-mW, 1392.54-nm distributed feedback laser is used at two of the locations to carry out water vapor measurements using direct absorption spectroscopy. This is the first instance of a portable tunable diode laser spectroscopy system being deployed in an urban location in India to measure atmospheric carbon dioxide and water vapor under varying traffic conditions. The measurements clearly demonstrate the need to adopt tunable diode laser spectroscopy for precise long-term monitoring of greenhouse gases in the Indian subcontinent. (C) 2017 Optical Society of America