Location of the embryo-transfer catheter guide before the internal uterine os improves the outcome of in vitro fertilization

被引:6
|
作者
Abdelmassih, Vicente G.
Neme, Rosa M.
Dozortsev, Dmitri
Abdelmassih, Soraya
Diamond, Michael P.
Abdelmassih, Roger
机构
[1] Department of Reproductive Health, Clínica e Centro, Pesquisa em Reprodução Humana Roger Abdelmassih, São Paulo
[2] Women's Comprehensive Care, Charleston Area Medical Center, Charleston, WV
[3] Women's Comprehensive Care, Wayne State University, Detroit, MI
关键词
D O I
10.1016/j.fertnstert.2006.11.007
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
The objective of this study was to assess whether positioning the embryo transfer (ET) catheter guide at the time of embryo expulsion, before or beyond the internal os, has an impact on IVF cycle outcome. We performed a retrospective study comparing IVF outcomes in relation to the ET guide position relative to the internal uterine os. We analyzed ultrasound-guided ETs in IVF-intracytoplasmic sperm injection (ICSI) cycles, performed with the tip of the ET catheter guide just before the internal os (group 1) and beyond the internal os (group 2). Implantation and pregnancy rates were significantly better in group I than in group 2, at 14.8% versus 11.8% and 57.3% versus 43.1, respectively. We conclude that passing the ET catheter guide beyond the internal os reduces implantation and pregnancy rates. (Fertil Steril((R)) 2007;88:499-503. (c) 2007 by American Society for Reproductive Medicine.).
引用
收藏
页码:499 / 503
页数:5
相关论文
共 50 条
  • [1] RELATIONSHIP BETWEEN THE DAY OF EMBRYO-TRANSFER AND THE OUTCOME IN HUMAN IN-VITRO FERTILIZATION AND EMBRYO-TRANSFER
    GOTO, Y
    KANZAKI, H
    NAKAYAMA, T
    TAKABATAKE, K
    HIMENO, T
    MORI, T
    NODA, Y
    [J]. JOURNAL OF ASSISTED REPRODUCTION AND GENETICS, 1994, 11 (08) : 401 - 404
  • [2] TRANSPORT IN-VITRO FERTILIZATION AND EMBRYO-TRANSFER
    BOOKER, M
    [J]. BRITISH JOURNAL OF HOSPITAL MEDICINE, 1993, 50 (07): : 369 - 370
  • [3] Cannulation of a resistant internal os with the malleable outer sheath of a coaxial soft embryo transfer catheter does not affect in vitro fertilization-embryo transfer outcome
    Silberstein, T
    Weitzen, S
    Frankfurter, D
    Trimarchi, JR
    Keefe, DL
    Plosker, SM
    [J]. FERTILITY AND STERILITY, 2004, 82 (05) : 1402 - 1406
  • [4] Contamination of Embryo Transfer Catheter and Treatment Outcome in In Vitro Fertilization
    Awoniyi Awonuga
    Abdel Nabi
    Jyoti Govindbhai
    Heidi Birch
    Bert Stewart
    [J]. Journal of Assisted Reproduction and Genetics, 1998, 15 : 198 - 201
  • [5] Contamination of embryo transfer catheter and treatment outcome in in vitro fertilization
    Awonuga, A
    Nabi, A
    Govindbhai, J
    Birch, H
    Stewart, B
    [J]. JOURNAL OF ASSISTED REPRODUCTION AND GENETICS, 1998, 15 (04) : 198 - 201
  • [6] Uterine contraction after embryo transfer and outcome of in-vitro fertilization and embryo transfer cycles
    Wong, A. W. Y.
    Kong, G. W. S.
    Haines, C. J.
    [J]. HUMAN REPRODUCTION, 2013, 28 : 245 - 245
  • [7] Change of embryo transfer strategy improves in-vitro fertilization-embryo transfer outcome
    Bárándi, ZS
    Vargha, P
    Urbancsek, J
    Papp, Z
    [J]. HUMAN REPRODUCTION, 1999, 14 : 189 - 190
  • [8] PROGRESS OF RESEARCH ON IN-VITRO FERTILIZATION AND EMBRYO-TRANSFER IN CHINA
    ZHANG, LZ
    [J]. CHINESE MEDICAL JOURNAL, 1995, 108 (04) : 245 - 248
  • [9] Gestational trophoblastic neoplasia after in vitro fertilization and embryo-transfer
    Couto, Silvia
    Metello, Jose Luis
    Ramos, Sandra
    Ferreira, Pedro
    Ilgenfritz, Raquel
    Sa e Melo, Pedro
    Elgindy, Eman
    [J]. MIDDLE EAST FERTILITY SOCIETY JOURNAL, 2016, 21 (03) : 199 - 203
  • [10] IN-VITRO FERTILIZATION AND EMBRYO-TRANSFER - A HISTORICAL-PERSPECTIVE
    PERONE, N