Maxillary zirconia implant fixed partial dentures opposing an acrylic resin implant fixed complete denture: A two-year clinical report

被引:13
|
作者
Chang, Paul P.
Henegbarth, Ernst A.
Lang, Lisa A.
机构
[1] Univ Texas, Hlth Sci Ctr, Sch Dent, Dept Prosthodont,Implant Div, San Antonio, TX 78229 USA
[2] Zen Line Dent, Bruchkoebel, Germany
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2007年 / 97卷 / 06期
关键词
D O I
10.1016/S0022-3913(07)60020-1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The fabrication of fixed Implant-supported prostheses for edentulous patients may be performed using all-ceramic or acrylic resin materials. This clinical report describes the fabrication and 2-year follow-up of maxillary zirconia Implant fixed partial dentures opposing a mandibular acrylic resin screw-retained fixed complete denture.
引用
收藏
页码:321 / 330
页数:10
相关论文
共 50 条
  • [31] Maxillary Rehabilitation Using Fixed and Removable Partial Dentures with Attachments: A Clinical Report
    dos Santos Nunes Reis, Jose Mauricio
    da Cruz Perez, Luciano Elias
    Moreira Alfenas, Bruna Fernandes
    Abi-Rached, Filipe de Oliveira
    Arioli Filho, Joao Neudenir
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (01): : 58 - 63
  • [32] Simplifying Prosthetic Procedures while Converting an Interim Maxillary Removable Complete Denture to an Interim Implant-Supported Fixed Complete Denture
    Michalakis, Konstantinos X.
    Touloumi, Foteini
    Calvani, Lino
    Bedi, Abheyjit
    Hirayama, Hiroshi
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2011, 20 (05): : 408 - 413
  • [33] Clinical and radiographic evaluations of implant-supported cantilever fixed partial dentures replacing maxillary anterior teeth: A randomized clinical trial
    Taha, Ahmed
    Al-Shahat, Mohamed A.
    Ghazy, Mohamed
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06): : 659 - 666
  • [34] Two-year clinical and SEM evaluation of glass-fiber-reinforced inlay fixed partial dentures
    Göhring, TN
    Schmidlin, PR
    Lutz, F
    AMERICAN JOURNAL OF DENTISTRY, 2002, 15 (01): : 35 - 40
  • [35] Five-year clinical results of zirconia frameworks for posterior fixed partial dentures
    Sailer, Irena
    Feher, Aurel
    Filser, Frank
    Gauckler, Ludwig J.
    Luethy, Heinz
    Hammerle, Christoph Hans Franz
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2007, 20 (04) : 383 - 388
  • [36] Influence of occlusal factors on treatment outcome: A study of 109 consecutive patients with mandibular implant-supported fixed prostheses opposing maxillary complete dentures
    Wennerberg, A
    Carlsson, GE
    Jemt, T
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2001, 14 (06) : 550 - 555
  • [37] Use of polyethylene ribbon to create a provisional fixed partial denture after immediate implant placement: A clinical report
    Eskitascioglu, G
    Eskitascioglu, A
    Belli, S
    JOURNAL OF PROSTHETIC DENTISTRY, 2004, 91 (01): : 11 - 14
  • [38] Use of a prefabricated fiber-reinforced composite resin framework to provide a provisional fixed partial denture over an integrating implant: A clinical report
    Meiers, JC
    Freilich, MA
    JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (01): : 14 - 18
  • [39] Immediate Loading of Maxillary and Mandibular Implant-Supported Fixed Complete Dentures: A 1- to 10-Year Retrospective Study
    Ji, Ting-Jen
    Kan, Joseph Y. K.
    Rungcharassaeng, Kitichai
    Roe, Phillip
    Lozada, Jaime L.
    JOURNAL OF ORAL IMPLANTOLOGY, 2012, 38 (01) : 469 - 476
  • [40] Restoring a severely resorbed maxillary anterior partially edentulous space using a one-piece titanium implant fixed partial denture: A clinical report
    Sierraalta, Marianella
    Razzoog, Michael E.
    JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (04): : 187 - 190