Application of Organic Photodiodes to X-ray Measurements - A Feasibility Study

被引:2
|
作者
Takada, Eiji [1 ]
Takada, Akinari [1 ]
Inoue, Akihiro [1 ]
Imai, Hideyuki [1 ]
Okada, Hiroyuki [2 ]
Naka, Shigeki [2 ]
Kawarabayashi, Jun [3 ]
Nakamura, Takashi [4 ]
Namito, Yoshihito [5 ]
机构
[1] Toyama Natl Coll Technol, 13 Hongo Machi, Toyama 9398630, Japan
[2] Toyama Univ, Toyama 9308555, Japan
[3] Nagoya Univ, Chikusa Ku, Nagoya, Aichi 4648603, Japan
[4] Tohoku Univ, Aoba Ku, Sendai, Miyagi 9808579, Japan
[5] High Energy Accelerator Res Org KEK, Tsukuba, Ibaraki 305, Japan
基金
日本学术振兴会;
关键词
organic photodiode (OPD); a-NPD; td-PTC; vapor deposition; X-ray; current; hetero; bulk hetero; efficiency; PHOTODETECTORS; DETECTORS; PROGRESS;
D O I
10.3327/jnst.48.1140
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
To elucidate the applicability of organic photodiodes (OPDs) to radiation measurements, three OPDs were fabricated, two with heterojunction structures (OPD-a and OPD-b) and one with a bulk-heterojunction structure (OPD-c). OPD-a and OPD-b have a structure of ITO/alpha-NPD/td-PTC/Al with a sensing area of 4 x 4 mm(2), while OPD-c has a 300-nm-thick mixed organic layer between alpha-NPD and td-PTC layers. All three OPDs showed rectifying properties under forward and reverse voltages. X-ray irradiation experiments have been carried out with these OPD devices. Results revealed that X-rays increased the output current, although some problems persisted, such as low photon-to-current conversion efficiency. When irradiating OPD-a and OPD-b with mono-energy X-rays at 20 keV, the current increased to about 6 pA from about 0.5 pA under dark conditions. The X-ray-induced current increased concomitantly with increasing X-ray intensity with some nonlinearity. Measurements of X-ray-induced current with OPD-c showed that it could yield a higher X-ray-induced current than those observed from OPD-a and OPD-b.
引用
收藏
页码:1140 / 1145
页数:6
相关论文
共 50 条
  • [1] Performance Measurements of Photodiodes for X-Ray Detection
    Baek, Jongmin
    Hwang, Sunmin
    Hyun, Hyojung
    Jang, Hoyoung
    Kim, Jinyong
    Kim, Seonghan
    Lee, Seungcheol
    Park, Hwanbae
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2022, 69 (08) : 1953 - 1959
  • [2] Feasibility study of silicon PN photodiodes as X-ray intensity monitors for high flux X-ray beam with synchrotron radiation
    Sato, K
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 285 - 290
  • [3] Feasibility study of silicon PN photodiodes as X-ray intensity monitors for high flux X-ray beam with synchrotron radiation
    Sato, Kazumichi
    [J]. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999, 436 (1-2): : 285 - 290
  • [4] X-ray Elastography: A Feasibility Study
    Kim, Gyu W.
    Han, Byung H.
    Cho, Min H.
    Lee, Soo Y.
    [J]. 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3513 - 3516
  • [5] Silicon avalanche photodiodes (APDs) for time resolved x-ray measurements
    Baron, AQR
    [J]. TIME STRUCTURE OF X-RAY SOURCES AND ITS APPLICATIONS, 1998, 3451 : 170 - 179
  • [6] APPLICATION OF A DUAL-ENERGY MONOCHROMATIC X-RAY CT ALGORITHM TO POLYCHROMATIC X-RAY CT: A FEASIBILITY STUDY
    Chang, S.
    Lee, H. K.
    Cho, G.
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2012, 44 (01) : 61 - 70
  • [7] Study of EUV and x-ray radiation hardness of silicon photodiodes
    Zabrodsky, Vladimir V.
    Aruev, Pavel N.
    Filimonov, Vladimir V.
    Sobolev, Nikolay A.
    Sherstnev, Evgeniy V.
    Belik, Viktor P.
    Nikolenko, Anton D.
    Ivlyushkin, Denis V.
    Pindyurin, Valery F.
    Shadrin, Nikita S.
    Soldatov, Artem E.
    Mashkovtsev, Mikhail R.
    [J]. DAMAGE TO VUV, EUV, AND X-RAY OPTICS IV; AND EUV AND X-RAY OPTICS: SYNERGY BETWEEN LABORATORY AND SPACE III, 2013, 8777
  • [8] PHOTODIODES AS DETECTORS WITH HIGH DYNAMIC-RANGE FOR X-RAY REFLECTIVITY MEASUREMENTS
    STORB, C
    DEDEK, U
    WEBER, W
    LENGELER, B
    SCHUSTER, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 306 (03): : 544 - 548
  • [9] Laser plasma X-ray measurements using thermoluminescent dosimeters and Si photodiodes
    Farnikova, M
    Krasa, J
    Kralikova, B
    Skala, J
    Parys, P
    Ryc, L
    Wolowski, J
    Woryna, E
    [J]. CZECHOSLOVAK JOURNAL OF PHYSICS, 1998, 48 (03) : 355 - 363
  • [10] Feasibility of a fluorescent X-ray source for in vivo X-ray fluorescence measurements of kidney and liver cadmium
    Börjesson, J
    Olsson, M
    Mattsson, S
    [J]. IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 255 - 258