Spherical neutron detector for space neutron measurement

被引:21
|
作者
Yamaguchi, S [1 ]
Uritani, A
Sakai, H
Mori, C
Iguchi, T
Toyokawa, H
Takeda, N
Kudo, K
机构
[1] Nagoya Univ, Grad Sch Engn, Dept Nucl Engn, Chikusa Ku, Nagoya, Aichi 4648603, Japan
[2] Electrotech Lab, Tsukuba, Ibaraki 3058568, Japan
关键词
spherical moderator; Li-6- and Li-7-glass scintillator; space neutrons;
D O I
10.1016/S0168-9002(98)00946-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A novel neutron detector has been developed to measure energy spectra of space neutrons in a spaceship. The detector consists of a spherical polyethylene moderator with a diameter of 30 cm and 19 pairs of Li-6- and Li-7-glass scintillators arranged along the orthogonal x-, y-, and z-axes of the sphere. The pairs can distinctively detect thermal neutrons in some radiation fields, where other radiation exists, by subtracting the number of detected events of the 7Li-glass scintillator from that of the Li-6-glass one. Hence the detector can clearly obtain the thermal neutron flux distribution in the spherical moderator even in such fields. The detector was applied to the measurement of monoenergetic and Cf-252 neutrons. The characteristics of the detector were studied by comparison with the simulations. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:600 / 605
页数:6
相关论文
共 50 条
  • [1] Neutron detector array for measurement of neutron multiplicity
    Palit, R
    Jain, HC
    Joshi, PK
    Nagaraj, S
    Panchal, HV
    Bhattacharya, S
    Chanda, S
    Basu, SK
    Chatterjee, MB
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 443 (2-3): : 386 - 391
  • [2] A SPHERICAL DOSE EQUIVALENT NEUTRON DETECTOR
    LEAKE, JW
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1966, 45 (01): : 151 - &
  • [3] AN IMPROVED SPHERICAL DOSE EQUIVALENT NEUTRON DETECTOR
    LEAKE, JW
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1968, 63 (03): : 329 - &
  • [4] High efficiency neutron detector for low neutron flux measurement
    Waheed A.
    Aqil-Ur-Rahman
    Zakaullah M.
    Murtaza G.
    [J]. Journal of Fusion Energy, 2000, 19 (1) : 91 - 92
  • [5] ENVIRONMENTAL NEUTRON MEASUREMENT BY MODERATING-TYPE NEUTRON DETECTOR
    NAKAMURA, T
    KOSAKO, T
    IWAI, S
    [J]. HEALTH PHYSICS, 1984, 46 (06): : 1326 - 1327
  • [6] High efficiency neutron detector for low neutron flux measurement
    Waheed, A
    Aqil-ur-Rahman
    Zakaullah, M
    Murtaza, G
    [J]. JOURNAL OF FUSION ENERGY, 2000, 19 (01) : 91 - 92
  • [7] GAMBE: Thermal Neutron Detector for Directional Measurement of Neutron Flux
    Ahmed, A.
    Burdin, S.
    Casse, G.
    van Zalinge, H.
    Powel, S.
    Rees, J.
    Smith, A.
    Tsurin, I.
    [J]. 2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [8] SIMULTANEOUS MEASUREMENT OF NEUTRON-FLUX AND NEUTRON DETECTOR EFFICIENCY
    DUPONT, C
    LELEUX, P
    LIPNIK, P
    SINDANO, WK
    WAUTERS, P
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 256 (02): : 339 - 341
  • [9] DIRECT MEASUREMENT OF NEUTRON DETECTOR EFFICIENCIES
    RIDDLE, RAJ
    HARRISON, GH
    ROOS, PG
    SALTMARSH, MJ
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1974, 121 (03): : 445 - 447
  • [10] Measurement of the efficiency of a neutron detector array
    Monroy, R
    Chávez, E
    Huerta, A
    Macias, R
    Ortiz, ME
    Barrón, L
    Ibañez, A
    Varela, A
    Murillo, G
    Policroniades, R
    Moreno, E
    [J]. NUCLEAR PHYSICS, LARGE AND SMALL, 2004, 726 : 237 - 238