Diagnostic accuracy of 64-slice computed tomography compared with coronary angiography

被引:0
|
作者
Valgeirsdottir, Inga Ros
Haraldsdottir, Sigurdis [1 ]
Scheving, Sigurpall S. [1 ]
Guojonsdottir, Jonina
Sigurosson, Axel F. [1 ]
Guonason, Porarinn [1 ]
Eyjolfsson, Kristjan [1 ]
Jonsdottir, Birna
Andersen, Karl [1 ]
机构
[1] Landspitala Hringbraut, IS-101 Reykjavik, Iceland
来源
LAEKNABLADID | 2008年 / 94卷 / 03期
关键词
coronary artery disease; multidetector computed tomography; cardiac catheterisation;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The aim of this study was to evaluate the diagnostic accuracy (sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV)) of 64-slice multidetector computed tomography (MDCT) compared with quantitative coronary angiography (QCA) for detection of coronary artery disease (CAD). Material and methods: Sixty-nine patients participating in a study of coronary in-stent restenosis were investigated. After a 64-slice MDCT scan patients were evaluated by QCA. The coronary arteries were divided into 15 segments and stenosis was graded for each segment by both methods. The diagnostic accuracy of 64-slice MDCT was evaluated using the OCA as the gold standard. Results: Among the 69 patients included in the study 13 (19%) were female and 56 male. The mean age was 63 (SD 10) years. The following risk factors were present: high blood pressure 67%, elevated blood cholesterol 54%, diabetes 12% and family history of CAD 71 %. Current smokers were 22% and previous smokers were 48%. Altogether 663 segments were examined. Of those 221 (33%) segments were excluded; 103 because of stents, 48 because of heavy calcification, 41 because of motion artifacts and 29 because the segments were less than 1.5 mm in diameter. The mean time between MDCT and QCA was 6.3 (SD 12.1) days. The sensitivity of 64-slice MDCT for diagnosing significant stenosis (>= 50% according to OCA) was 20%, the specificity was 94%, PPV was 16%, NPV was 95% and the accuracy was 89%. Conclusion: High NPV and specificity indicates that MDCT is useful for accurately excluding significant CAD but the low sensitivity and low PPV indicate that the method is not accurate in diagnosing coronary artery stenosis of 50% or more according to QCA.
引用
收藏
页码:199 / 205
页数:7
相关论文
共 50 条
  • [1] Diagnostic Accuracy of 64-Slice Computed Tomography Coronary Angiography
    Meijboom, W. Bob
    Meijs, Matthijs F. L.
    Schuijf, Joanne D.
    Cramer, Maarten J.
    Mollet, Nico R.
    van Mieghem, Carlos A. G.
    Nieman, Koen
    van Werkhoven, Jacob M.
    Pundziute, Gabija
    Weustink, Annick C.
    de Vos, Alexander M.
    Pugliese, Francesca
    Rensing, Benno
    Jukema, J. Wouter
    Bax, Jeroen J.
    Prokop, Mathias
    Doevendans, Pieter A.
    Hunink, Myriam G. M.
    Krestin, Gabriel P.
    de Feyter, Pim J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (25) : 2135 - 2144
  • [2] Diagnostic accuracy of 64-Slice Computed Tomography Coronary Angiography in women
    Meijboom, W. B.
    Weustink, A. C.
    Pugliese, F.
    Van Mieghem, C. A. G.
    Mollet, N. R.
    Van Pelt, N.
    Nieman, K.
    Cademartiri, F.
    Krestin, G. P.
    De Feyter, P. J.
    [J]. EUROPEAN HEART JOURNAL, 2007, 28 : 494 - 494
  • [3] 64-slice computed tomography coronary angiography:: diagnostic accuracy in the real world
    Cademartiri, F.
    Maffei, E.
    Notarangelo, F.
    Ugo, F.
    Palumbo, A.
    Lina, D.
    Aldrovandi, A.
    Solinas, E.
    Reverberi, C.
    Menozzi, A.
    Vignali, L.
    Malago, R.
    Midiri, M.
    Mollet, N. R.
    Cervellin, G.
    Ardissino, D.
    [J]. RADIOLOGIA MEDICA, 2008, 113 (02): : 163 - 180
  • [4] Diagnostic Accuracy of 64-Slice Computed Tomography Coronary Angiography A Flawed Comparison
    Nicol, Edward D.
    Stirrup, James
    Padley, Simon P. G.
    Rubens, Michael B.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (19) : 1824 - 1825
  • [5] Diagnostic accuracy of coronary angiography using 64-slice computed tomography in coronary artery disease
    Yang, Fu-Bin
    Guo, Wan-Liang
    Sheng, Mao
    Sun, Ling
    Ding, Yue-Yue
    Xu, Qiu-Qin
    Xu, Ming-Guo
    Lv, Hai-Tao
    [J]. SAUDI MEDICAL JOURNAL, 2015, 36 (10) : 1156 - 1162
  • [6] Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography
    Raff, GL
    Gallagher, MJ
    O'Neill, W
    Goldstein, JA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (03) : 552 - 557
  • [7] Diagnostic Accuracy of 64-Slice Computed Tomography Coronary Angiography A Flawed Comparison - Reply
    Meijboom, W. Bob
    Meijs, Matthijs F. L.
    Schuijf, Joanne D.
    Cramer, Maarten J.
    Mollet, Nico R.
    van Mieghem, Carlos A. G.
    Nieman, Koen
    van Werkhoven, Jacob M.
    Pundziute, Gabija
    Weustink, Annick C.
    de Vos, Alexander M.
    Pugliese, Francesca
    Rensing, Benno
    Jukema, J. Wouter
    Bax, Jeroen J.
    Prokop, Mathias
    Doevendans, Pieter A.
    Hunink, Myriam G.
    Krestin, Gabriel P.
    de Feyter, Pim J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (19) : 1825 - 1826
  • [8] Diagnostic accuracy of 64-slice computed tomography coronary angiography: A multicenter, multivendor, prospective study
    Meijboom, W. Bob
    Meijs, Matthijs F.
    Schuijf, Joanne D.
    Mollet, Nico R.
    van Mieghem, Carlos A. G.
    Nieman, Koen
    van Werkhoven, Jaap M.
    Pundziute, Gabija
    Weustink, Annick C.
    Cramer, Maarten J.
    Jukema, Wouter J.
    Bax, Jeroen J.
    Doevendans, Pieter A.
    Prokop, Mathias
    Knestin, Gabriel P.
    de Feyter, Pim J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : A145 - A145
  • [9] Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective multicenter, multivendor study
    Meijboom, W. B.
    Meijs, M. F. L.
    Schuijf, J. D.
    Cramer, M. J.
    Mollet, N. R.
    Van Mieghem, C. A.
    Bax, J. J.
    Doevendans, P. A.
    Krestin, G. P.
    De Feyter, P. J.
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 : 617 - 617
  • [10] Diagnostic accuracy of 64-slice computed tomography coronary angiography in patients with low-to-intermediate risk
    Cademartiri, F.
    Maffei, E.
    Palumbo, A.
    Malago, R.
    Alberghina, F.
    Aldrovandi, A.
    Brambilla, V.
    Runza, G.
    La Grutta, L.
    Menozzi, A.
    Vignali, L.
    Casolo, G.
    Midiri, M.
    Mollet, N. R.
    [J]. RADIOLOGIA MEDICA, 2007, 112 (07): : 969 - 981