Clinical and radiologic outcome of laminar screw at C2 and C7 for posterior instrumentation-review of 25 cases and comparison of C2 and C7 intralaminar screw fixation

被引:35
|
作者
Hong, Jae Taek [1 ]
Yi, Jin Seok [1 ]
Kim, Jong Tae [1 ]
Ji, Chul [1 ]
Ryu, Kyung Sik [1 ]
Park, Chun Kun [1 ]
机构
[1] Catholic Univ Korea, Dept Neurosurg, Seoul, South Korea
关键词
Cervical spine; Posterior screw fixation; Intralaminar screw; CERVICAL PEDICLE; ANATOMICAL CONSIDERATIONS; BIOMECHANICAL EVALUATION; QUANTITATIVE ANATOMY; LATERAL MASS; PLACEMENT; STABILIZATION; INSERTION; ACCURACY; SPINE;
D O I
10.1016/j.surneu.2009.06.010
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: The aim of this study is 2-fold: to analyze a clinical case series in which we used laminar screws for cervical posterior instrumentation and to describe the difference between C2 and C7 laminar screws in terms of technique and anatomy. Methods: Data were obtained from 25 patients who underwent cervical posterior fixation with intralaminar screws at C2 or C7. C2 intralaminar screw instrumentation was used for 7 patients requiring occipitocervical fixation (basilar invagination [3 patients], Cl unstable bursting fracture [1 patient], C1-C2 instability with occipital assimilation [2 patients], and dystopic os odontoideum [1 patient]), 13 patients with C1-C2 instability, 1 patient with C2-C3 subluxation, and 4 patients undergoing C7 fixation due to pseudoarthrosis or cervical instability after trauma. A total of 34 laminar screws were placed including 1 thoracic laminar screw, and the patients were assessed both clinically and radiographically. Results: There were no instances where a screw violated the spinal canal nor any hardware fractures noted during the follow-up period. As for perioperative complications, there were 2 cases of postoperative wound infection, 1 case of dural laceration during dissection, and 2 cases of partial dorsal laminar breach. However, there was no neurologic compromise in any of the cases. The fusion success rate was 100%. Conclusion: These preliminary results support the use of intralaminar screws for posterior instrumentation at C2 and C7. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:112 / 118
页数:7
相关论文
共 50 条
  • [1] Biomechanical Effect of the C2 Laminar Decortication on the Stability of C2 Intralaminar Screw Construct and Biomechanical Comparison of C2 Intralaminar Screw and C2 Pars Screw
    Hong, Jae Taek
    Takigawa, Tomoyuki
    Udayakunmar, Ranjith
    Shin, Hun Kyu
    Simon, Peter
    Orias, Alejandro A. Espinoza
    Inoue, Nozomu
    An, Howard S.
    [J]. NEUROSURGERY, 2011, 69 : 1 - 6
  • [2] Biomechanical Effect of the C2 Laminar Decortication on the Stability of C2 Intralaminar Screw Construct and Biomechanical Comparison of C2 Intralaminar Screw and C2 Pars Screw COMMENTS
    Benzel, Edward C.
    Crawford, Neil R.
    Sonntag, Volker K. H.
    [J]. NEUROSURGERY, 2011, 69 : 6 - 7
  • [3] C7 Posterior Fixation Using Intralaminar Screws: Early Clinical and Radiographic Outcome
    Jang, Sang Hoon
    Hong, Jae Taek
    Kim, Il Sup
    Yeo, In Sung
    Son, Byung Chul
    Lee, Sang Won
    [J]. JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2010, 48 (02) : 129 - 133
  • [4] Biomechanical Comparison of Three Different Types of C7 Fixation Techniques Lateral Mass Screw, Transpedicular Screw, and Intralaminar Screw
    Hong, Jae Taek
    Tomoyuki, Takigawa
    Udayakumar, Ranjith
    Orias, Alejandro A. Espinoza
    Inoue, Nozomu
    An, Howard S.
    [J]. SPINE, 2011, 36 (05) : 393 - 398
  • [5] POSTERIOR INSTRUMENTATION FOR LAMINAR SCREW OF C2: A DIMENSIONAL ANATOMIC STUDY OF AXIS
    Sorrenti, Luiz
    Iamaguchi, Mauricio Masasi
    Sposeto, Rafael Barban
    de Araujo, Marcelo Poderoso
    Iutaka, Alexandre Sadao
    Pessoa de Barros Filho, Tarcisio Eloy
    da Rocha, Ivan Dias
    [J]. ACTA ORTOPEDICA BRASILEIRA, 2009, 17 (04): : 219 - 223
  • [6] A concise synthesis of C2′-C7′ fragment of aigialomycin D
    Zhang Hong-Kui
    Chen Wei-Qiang
    [J]. CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2007, 28 (04): : 689 - 691
  • [7] Pyrazolopyridine antiherpetics:: SAR of C2′ and C7 amine substituents
    Johns, BA
    Gudmundsson, KS
    Turner, EM
    Allen, SH
    Samano, VA
    Ray, JA
    Freeman, GA
    Boyd, FL
    Sexton, CJ
    Selleseth, DW
    Creech, KL
    Moniri, KR
    [J]. BIOORGANIC & MEDICINAL CHEMISTRY, 2005, 13 (07) : 2397 - 2411
  • [8] Clinical application of C2 laminar screw technique
    Ma, Weihu
    Feng, Leling
    Xu, Rongming
    Liu, Xiaochen
    Lee, Alan H.
    Sun, Shaohua
    Zhao, Liujun
    Hu, Yong
    Liu, Guanyi
    [J]. EUROPEAN SPINE JOURNAL, 2010, 19 (08) : 1312 - 1317
  • [9] Clinical application of C2 laminar screw technique
    Weihu Ma
    Leling Feng
    Rongming Xu
    Xiaochen Liu
    Alan H. Lee
    Shaohua Sun
    Liujun Zhao
    Yong Hu
    Guanyi Liu
    [J]. European Spine Journal, 2010, 19 : 1312 - 1317
  • [10] ANATOMICAL CONSIDERATIONS IN POSTERIOR SCREW FIXATION OF C1 AND C2
    FERON, JM
    SIGNORET, F
    LAZENNEC, JY
    [J]. ACTA ANATOMICA, 1987, 130 (01): : 30 - 31