Utility of combined CT coronary angiography and SPECT myocardial perfusion imaging for the detection of functionally relevant coronary stenoses

被引:0
|
作者
Mohan, P. [1 ]
Vaidya, A. [1 ]
Kaul, U. [1 ]
Mahajan, H. [1 ]
机构
[1] Mahajan Imaging, New Delhi, India
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
EP-0195
引用
收藏
页码:S513 / S513
页数:1
相关论文
共 50 条
  • [1] Combined CT angiography and SPECT myocardial perfusion imaging for the detection of functionally relevant coronary stenoses
    Li, Jian-Ming
    Shi, Rong-Fang
    Zhang, Li-Ren
    Li, Ting
    Dong, Zhi
    [J]. MOLECULAR MEDICINE REPORTS, 2013, 7 (05) : 1391 - 1396
  • [2] Accuracy of 64-slice CT angiography for the detection of functionally relevant coronary stenoses as assessed by myocardial perfusion SPECT
    Gaemperli, Oliver
    Schepis, Tiziano
    Koepfli, Pascal
    Siegrist, Patrick T.
    Namdar, Mehdi
    Valenta, Ines
    Soyka, Jan
    Leschka, Sebastian
    Desbiolles, Lotus
    husmann, lars
    Alkadhi, Hatem
    Kaufmann, Philipp A.
    [J]. CIRCULATION, 2006, 114 (18) : 583 - 583
  • [3] Accuracy of 64-slice CT angiography for the detection of functionally relevant coronary stenoses as assessed with myocardial perfusion SPECT
    Gaemperli, Oliver
    Schepis, Tiziano
    Koepfli, Pascal
    Valenta, Ines
    Soyka, Jan
    Leschka, Sebastian
    Desbiolles, Lotus
    Husmann, Lars
    Alkadhi, Hatem
    Kaufmann, Philipp A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (08) : 1162 - 1171
  • [4] Accuracy of 64-slice CT angiography for the detection of functionally relevant coronary stenoses as assessed with myocardial perfusion SPECT
    Oliver Gaemperli
    Tiziano Schepis
    Pascal Koepfli
    Ines Valenta
    Jan Soyka
    Sebastian Leschka
    Lotus Desbiolles
    Lars Husmann
    Hatem Alkadhi
    Philipp A. Kaufmann
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 1162 - 1171
  • [5] Comparison of 64-slice spiral CT angiography and myocardial perfusion imaging in noninvasive evaluation of functionally relevant coronary stenoses
    Gaemperli, O.
    Schepis, T.
    Koepfli, P.
    Namdar, M.
    Valenta, I.
    Leschka, S.
    Kaufmann, P.
    Alkadhi, H.
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 : 285 - 285
  • [6] Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography
    S. Feger
    M. Rief
    E. Zimmermann
    F. Richter
    R. Roehle
    M. Dewey
    E. Schönenberger
    [J]. European Radiology, 2015, 25 : 2115 - 2124
  • [7] Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography
    Feger, S.
    Rief, M.
    Zimmermann, E.
    Richter, F.
    Roehle, R.
    Dewey, M.
    Schoenenberger, E.
    [J]. EUROPEAN RADIOLOGY, 2015, 25 (07) : 2115 - 2124
  • [8] 64-slice CT angiography for the detection of functionally significant coronary stenoses: comparison with stress myocardial perfusion imaging
    Chen, M-L
    Mo, Y-H
    Wang, Y-C
    Lo, H-S
    Wang, P-C
    Chao, I-M
    Su, H-Y
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1012): : 368 - 376
  • [9] Comparison of 64-slice spiral ct angiography versus myocardial perfusion imaging in noninvasive evaluation of functionally relevant coronary stenoses
    Gaemperli, O.
    Schepis, T.
    Koepfli, P.
    Namdar, M.
    Valenta, P. T. Siegrist I.
    Soyka, J.
    Leschka, S.
    Desbiolles, L.
    Husmann, L.
    Alkadhi, H.
    Kaufmann, P. A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S129 - S129
  • [10] Functionally relevant coronary artery disease: Comparison of 64-section CT angiography with myocardial perfusion SPECT
    Gaemperli, Oliver
    Schepis, Tiziano
    Valenta, Ines
    Koepfli, Pascal
    Husmann, Lars
    Scheffel, Hans
    Leschka, Sebastian
    Eberli, Franz R.
    Luscher, Thomas F.
    Alkadhi, Hatem
    Kaufmann, Philipp A.
    [J]. RADIOLOGY, 2008, 248 (02) : 414 - 423