Development of a selective sorbent based on a magnetic ion imprinted polymer for the preconcentration and FAAS determination of urinary cadmium

被引:30
|
作者
Panjali, Zahra [1 ]
Asgharinezhad, Ali Akbar [2 ]
Ebrahimzadeh, Homeira [2 ]
Karami, Sara [2 ]
Loni, Masood [2 ]
Rezvani, Mehdi [2 ]
Yarahmadi, Rasoul [3 ]
Shahtaheri, Seyed Jamaleddin [1 ,4 ]
机构
[1] Univ Tehran Med Sci, Sch Publ Hlth, Dept Occupat Hlth Engn, Tehran, Iran
[2] Shahid Beheshti Univ, Sch Chem, Dept Appl Chem, Tehran, Iran
[3] Iran Univ Med Sci, Sch Publ Hlth, Dept Occupat Hlth Engn, Tehran, Iran
[4] Univ Tehran Med Sci, Inst Environm Res, Tehran, Iran
关键词
SOLID-PHASE EXTRACTION; ATOMIC-ABSORPTION-SPECTROMETRY; TRACE DETERMINATION; WATER SAMPLES; LEAD; NANOPARTICLES; PB(II); NICKEL; COPPER; NANOCOMPOSITE;
D O I
10.1039/c4ay03066d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, an ion imprinted polymer (IIP), based on coating of a polymer on a Fe3O4 nanoparticle (NP) core, is used as a magnetic sorbent for the preconcentration and determination of the Cd(II) ion level in human urine samples. The synthesized polymer was characterized by IR spectroscopy, scanning electron microscopy (SEM), X-ray diffraction analysis (XRD) and thermal analysis (TG/DTA). The optimum conditions, such as pH of the sample, eluent volume, concentration and duration of sorption and elution, were investigated. In addition, the effect of some potentially interfering cations on the sorption of Cd(II) was confirmed. In all samples, Cd(II) was determined using a flame atomic absorption spectrophotometer. Under optimal conditions, the limit of detection (LOD) of cadmium was 0.6 mu g L-1. The optimized method has been validated using day-to-day and within-day reproducible experiments and achieved appropriate accuracy and precision. The accuracy of the method was confirmed by analyzing a certified reference material (Seronorm LOT NO2525) and spiked real samples. Ultimately, this method was applied successfully for the preconcentration and determination of Cd(II) ions in urine samples obtained from exposed individuals.
引用
收藏
页码:3618 / 3624
页数:7
相关论文
共 50 条
  • [1] A Simple and Fast Method Based on New Magnetic Ion Imprinted Polymer as a Highly Selective Sorbent for Preconcentration and Determination of Cadmium in Environmental Samples
    Panjali, Zahra
    Asgharinezhad, Ali Akbar
    Ebrahimzadeh, Homeira
    Jalilian, Niloofar
    Yarahmadi, Rasoul
    Shahtaheri, Seyed Jamaleddin
    [J]. IRANIAN JOURNAL OF PUBLIC HEALTH, 2016, 45 (08) : 1044 - 1053
  • [2] An ion imprinted amino-functionalized mesoporous sorbent for the selective minicolumn preconcentration of cadmium ions and determination by GFAAS
    Minaberry, Yanina Susana
    Tudino, Mabel
    [J]. ANALYTICAL METHODS, 2018, 10 (44) : 5305 - 5312
  • [3] A New Magnetic Pb (II)-Imprinted Polymer as a Highly Selective Sorbent for Preconcentration and Determination of Lead Ions in Wastewater Samples
    Yang, Lin
    Li, Sheng-Fang
    Song, Wei-Jun
    Sun, Chun-Yan
    [J]. MATERIALS IN ENVIRONMENTAL ENGINEERING, 2017, : 1125 - 1141
  • [4] A new magnetic ion-imprinted polymer as a highly selective sorbent for determination of cobalt in biological and environmental samples
    Khoddami, Nafiseh
    Shemirani, Farzaneh
    [J]. TALANTA, 2016, 146 : 244 - 252
  • [5] Assessment of ion imprinted polymers based on Pd(II) chelate complexes for preconcentration and FAAS determination of palladium
    Godlewska-Zylkiewicz, Beata
    Lesniewska, Barbara
    Wawreniuk, Irena
    [J]. TALANTA, 2010, 83 (02) : 596 - 604
  • [6] A Novel Magnetic Cd(II) Ion-Imprinted Polymer as a Selective Sorbent for the Removal of Cadmium Ions from Aqueous Solution
    Hongpeng Wang
    Yuecheng Lin
    Yin Li
    Anudari Dolgormaa
    Hui Fang
    Lin Guo
    Jun Huang
    Junxing Yang
    [J]. Journal of Inorganic and Organometallic Polymers and Materials, 2019, 29 : 1874 - 1885
  • [7] Application of a metal ion-imprinted polymer based on salen-Cu complex to flow injection preconcentration and FAAS determination of copper
    Walas, Stanislaw
    Tobiasz, Anna
    Gawin, Marta
    Trzewik, Bartosz
    Strojny, Marcin
    Mrowiec, Halina
    [J]. TALANTA, 2008, 76 (01) : 96 - 101
  • [8] A Novel Magnetic Cd(II) Ion-Imprinted Polymer as a Selective Sorbent for the Removal of Cadmium Ions from Aqueous Solution
    Wang, Hongpeng
    Lin, Yuecheng
    Li, Yin
    Dolgormaa, Anudari
    Fang, Hui
    Guo, Lin
    Huang, Jun
    Yang, Junxing
    [J]. JOURNAL OF INORGANIC AND ORGANOMETALLIC POLYMERS AND MATERIALS, 2019, 29 (06) : 1874 - 1885
  • [9] Preconcentration of copper on ion-selective imprinted polymer microbeads
    Say, R
    Birlik, E
    Ersöz, A
    Yilmaz, F
    Gedikbey, T
    Denizli, A
    [J]. ANALYTICA CHIMICA ACTA, 2003, 480 (02) : 251 - 258
  • [10] Cadmium ion-selective sorbent preconcentration method using ion imprinted poly(ethylene glycol dimethacrylate-co-vinylimidazole)
    Segatelli, Mariana Gava
    Santos, Vivian Silva
    Teixeira Presotto, Amanda Braga
    Pagotto Yoshida, Inez Valeria
    Teixeira Tarley, Cesar Ricardo
    [J]. REACTIVE & FUNCTIONAL POLYMERS, 2010, 70 (06): : 325 - 333