Deceased donor kidney transplantation across donor-specific antibody barriers: predictors of antibody-mediated rejection

被引:55
|
作者
Schwaiger, Elisabeth [1 ]
Eskandary, Farsad [1 ,2 ]
Kozakowski, Nicolas [3 ]
Bond, Gregor [1 ]
Kikic, Zeljko [1 ]
Yoo, Daniel [4 ]
Rasoul-Rockenschaub, Susanne [5 ]
Oberbauer, Rainer [1 ]
Boehmig, Georg A. [1 ]
机构
[1] Med Univ Vienna, Dept Med 3, Div Nephrol & Dialysis, Vienna, Austria
[2] Univ Alberta, ATAGC, Edmonton, AB, Canada
[3] Med Univ Vienna, Dept Clin Pathol, Vienna, Austria
[4] Univ Alberta, Heritage Med Res Ctr 250, Transcriptome Sci Inc, Edmonton, AB, Canada
[5] Med Univ Vienna, Ctr Med Stat Informat & Intelligent Syst, Vienna, Austria
关键词
antibody-mediated rejection; crossmatch; donor-specific antibodies; immunoadsorption; kidney transplantation; POSITIVE CROSS-MATCH; SENSITIZED PATIENTS; HLA ANTIBODIES; PERITRANSPLANT IMMUNOADSORPTION; RECIPIENTS; OUTCOMES; DESENSITIZATION; PATIENT; RISK;
D O I
10.1093/ndt/gfw027
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Apheresis-based desensitization allows for successful transplantation across major immunological barriers. For donor-specific antibody (DSA)- and/or crossmatch-positive transplantation, however, it has been shown that even intense immunomodulation may not completely prevent antibody-mediated rejection (ABMR). In this study, we evaluated transplant outcomes in 101 DSA+ deceased donor kidney transplant recipients (transplantation between 2009 and 2013; median follow-up: 24 months) who were subjected to immunoadsorption (IA)-based desensitization. Treatment included a single pre-transplant IA session, followed by anti-lymphocyte antibody and serial post-transplant IA. In 27 cases, a positive complement-dependent cytotoxicity crossmatch (CDCXM) was rendered negative immediately before transplantation. Seventy-four of the DSA+ recipients had a negative CDCXM already before IA. Three-year death-censored graft survival in DSA+ patients was significantly worse than in 513 DSA- recipients transplanted during the same period (79 versus 88%, P = 0.008). Thirty-three DSA+ recipients (33%) had ABMR. While a positive baseline CDCXM showed only a trend towards higher ABMR rates (41 versus 30% in CDCXM- recipients, P = 0.2), DSA mean fluorescence intensity (MFI) in single bead assays significantly associated with rejection, showing 20 versus 71% ABMR rates at < 5000 versus > 15 000 peak DSA MFI. The predictive value of MFI was moderate, with the highest accuracy at a median of 13 300 MFI (after cross-validation: 0.72). Other baseline variables, including CDC assay results, human leukocyte antigen mismatch, prior transplantation or type of induction treatment, did not add independent predictive information. IA-based desensitization failed to prevent ABMR in a considerable number of DSA+ recipients. Assessing DSA MFI may help stratify risk of rejection, supporting its use as a guide to organ allocation and individualized treatment.
引用
收藏
页码:1342 / 1351
页数:10
相关论文
共 50 条
  • [1] ANTIBODY-MEDIATED REJECTION WITH AND WITHOUT HLA DONOR-SPECIFIC ANTIBODIES IN KIDNEY TRANSPLANTATION
    Crespo, Marta
    Redondo, Dolores
    Butler, Carrie
    Gimeno, Javier
    Garcia, Carme
    Jose Perez-Saez, M.
    Burballa, Carla
    Mir, Marisa
    Faura, Anna
    Valenzuela, Nicole M.
    Reed, Elaine F.
    Pascual, Julio
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2018, 33
  • [2] Donor-specific HLA antibody characteristics at the time of biopsy with and without antibody-mediated rejection in kidney transplantation
    Kaneku, H.
    Mateu, D.
    Hernandez, A.
    Fernandez-Bango, C.
    Ruiz, P.
    [J]. HUMAN IMMUNOLOGY, 2023, 84 : 114 - 114
  • [3] Donor-Specific Antibody Levels and Three Generations of Crossmatches to Predict Antibody-Mediated Rejection in Kidney Transplantation
    Riethmueller, Sebastian
    Ferrari-Lacraz, Sylvie
    Mueller, Markus K.
    Raptis, Dimitri A.
    Hadaya, Karine
    Ruesi, Barbara
    Laube, Guido
    Schneiter, Gregory
    Fehr, Thomas
    Villard, Jean
    [J]. TRANSPLANTATION, 2010, 90 (02) : 160 - 167
  • [4] Antibody-Mediated Rejection With and Without HLA Donor-Specific Antibodies in Kidney-Transplantation
    Crespo, Marta
    Redondo, Dolores
    Butler, Carrie
    Gimeno, Javier
    Garcia, Carme
    Jose Perez, Maria
    Burballa, Carla
    Mir, Marisa
    Faura, Anna
    Valenzuela, Nicole M.
    Reed, Elaine F.
    Julio, Pascual
    [J]. TRANSPLANTATION, 2018, 102 : S211 - S212
  • [5] Bortezomib for antibody-mediated rejection of kidney transplant in youth: Associations with donor-specific antibody
    Fulchiero, Rosanna
    Galea, Lauren
    Hewlett, Jennifer
    Savant, Jonathan D.
    Lopez, Sonya
    Amaral, Sandra
    Viteri, Bernarda
    [J]. PEDIATRIC TRANSPLANTATION, 2024, 28 (05)
  • [6] Antibody-Mediated Rejection in Lung Transplantation: Clinical Outcomes and Donor-Specific Antibody Characteristics
    Roux, A.
    Le Lan, I. Bendib
    Holifanjaniaina, S.
    Thomas, K. A.
    Hamid, A. M.
    Picard, C.
    Grenet, D.
    De Miranda, S.
    Douvry, B.
    Beaumont-Azuar, L.
    Sage, E.
    Devaquet, J.
    Cuquemelle, E.
    Le Guen, M.
    Spreafico, R.
    Suberbielle-Boissel, C.
    Stern, M.
    Parquin, F.
    [J]. AMERICAN JOURNAL OF TRANSPLANTATION, 2016, 16 (04) : 1216 - 1228
  • [7] Safety and efficacy of eculizumab for the prevention of antibody-mediated rejection after deceased-donor kidney transplantation in patients with preformed donor-specific antibodies
    Glotz, Denis
    Russ, Graeme
    Rostaing, Lionel
    Legendre, Christophe
    Tufveson, Gunnar
    Chadban, Steve
    Grinyo, Josep
    Mamode, Nizam
    Rigotti, Paolo
    Couzi, Lionel
    Buchler, Matthias
    Sandrini, Silvio
    Dain, Bradley
    Garfield, Mary
    Ogawa, Masayo
    Richard, Tristan
    Marks, William H.
    [J]. AMERICAN JOURNAL OF TRANSPLANTATION, 2019, 19 (10) : 2865 - 2875
  • [8] TIMING OF DONOR-SPECIFIC HLA ANTIBODY TESTING IN THE DIAGNOSIS OF ANTIBODY-MEDIATED REJECTION IN KIDNEY ALLOGRAFTS
    Kaneku, H.
    Mateu, D.
    Fernandez-Bango, C.
    Ruiz, P.
    [J]. HUMAN IMMUNOLOGY, 2022, 83 : 113 - 113
  • [9] Biopsy and Donor-Specific Antibody Trends Associated with Plasmapheresis for Antibody-Mediated Rejection in Heart Transplantation
    Chang, B.
    Klein, K. L.
    Tint, H.
    Ling, M.
    Sieg, A.
    Wahed, A.
    Nedelcu, E. G.
    Nguyen, A.
    Nathan, S.
    Bai, Y.
    [J]. TRANSFUSION, 2014, 54 : 126A - 127A
  • [10] Characteristics of Donor-Specific Antibodies Associated With Antibody-Mediated Rejection in Lung Transplantation
    Roux, Antoine
    Le Lan, Ines Bendib
    Holifanjaniaina, Sonia
    Thomas, Kimberly A.
    Picard, CleMent
    Grenet, Dominique
    De Miranda, Sandra
    Douvry, Benoit
    Beaumont-Azuar, Laurence
    Sage, Edouard
    Devaquet, Jerome
    Cuquemelle, Elise
    Le Guen, Morgan
    Suberbielle, Caroline
    Gautreau, Chantal
    Stern, Marc
    Rossetti, Maura
    Hamid, Abdul Monem
    Parquin, Francois
    [J]. FRONTIERS IN MEDICINE, 2017, 4