Linearity testing of precision analog-to-digital converters using stationary nonlinear inputs

被引:0
|
作者
Jin, L [1 ]
Parthasarathy, K [1 ]
Kuyel, T [1 ]
Chen, DG [1 ]
Geiger, RL [1 ]
机构
[1] Iowa State Univ, Dept Elect & Comp Engn, Ames, IA 50011 USA
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
As the performance of Analog-to-Digital Converters continues to improve, it is becoming more challenging and costly to develop sufficiently fast and low-drift signal generators that are adequately more linear than the ADC for the purpose of linearity testing. This work relaxes the linearity requirements on the signal generators used for ADC testing by alternatively employing. multiple non-linear inputs. Assuming minimal prior knowledge of the input non-linearity, a testing methodology is introduced that is based upon first identifying and computationally removing the source non-linearity and then accurately estimating the ADC linearity. Production test hardware is used for validating the performance of this testing methodology using a high performance 16-bit SAR ADC as a test vehicle. Integral linearity error readings are identified to well within the +/-2 LSB range of the device specification by using only 8-bit linear inputs. This approach provides an enabling technology for cost-effective full-code testing of high performance ADCs in production test and for a cost-effective implementation of built-in self-test (BIST).
引用
收藏
页码:218 / 227
页数:10
相关论文
共 50 条
  • [1] Optimal linearity testing of analog-to-digital converters using a linear model
    Cherubal, S
    Chatterjee, A
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2003, 50 (03) : 317 - 327
  • [2] Linearity Testing of Analog-to-Digital Converters using Imprecise Sinusoidal Excitations
    Vasan, Bharath K.
    Chen, Degang J.
    Geiger, Randall L.
    PROCEEDINGS OF THE IEEE 2010 NATIONAL AEROSPACE AND ELECTRONICS CONFERENCE (NAECON), 2010, : 334 - 337
  • [3] Application of the Kalman Filter in Linearity Testing of Analog-to-Digital Converters
    Jin, Le
    JOURNAL OF ELECTRONIC TESTING-THEORY AND APPLICATIONS, 2011, 27 (02): : 163 - 175
  • [4] Application of the Kalman Filter in Linearity Testing of Analog-to-Digital Converters
    Le Jin
    Journal of Electronic Testing, 2011, 27 : 163 - 175
  • [5] Linearity test of analog-to-digital converters using Kalman filtering
    Jin, Le
    Chen, Degang
    Geiger, Randall
    2006 IEEE INTERNATIONAL TEST CONFERENCE, VOLS 1 AND 2, 2006, : 805 - +
  • [6] SIGNATURE TESTING OF ANALOG-TO-DIGITAL CONVERTERS
    Geurkov, Vadim
    Kirischian, Valeri
    Kirischian, Lev
    XIX IMEKO WORLD CONGRESS: FUNDAMENTAL AND APPLIED METROLOGY, PROCEEDINGS, 2009, : 706 - 709
  • [7] ON NONLINEAR DISTORTIONS IN ANALOG-TO-DIGITAL CONVERTERS
    RYZHAK, IS
    RADIOTEKHNIKA I ELEKTRONIKA, 1991, 36 (04): : 755 - 766
  • [8] TESTING METHODOLOGIES FOR ANALOG-TO-DIGITAL CONVERTERS
    BRANDOLINI, A
    GANDELLI, A
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1992, 41 (05) : 595 - 603
  • [9] A survey on nonlinear analog-to-digital converters
    Santos, Mauro
    Horta, Nuno
    Guilherme, Jorge
    INTEGRATION-THE VLSI JOURNAL, 2014, 47 (01) : 12 - 22
  • [10] PROPERTIES OF LOW PRECISION ANALOG-TO-DIGITAL CONVERTERS
    COLLINS, FA
    SICKING, CJ
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1976, 12 (05) : 643 - 646