Solutions of Electrical Control and Management System for Thermal Power Plant Based on IEC61850

被引:0
|
作者
Hou Wei [1 ]
Yang Yan [1 ]
Yan Wei [1 ]
Zhang Chunhe [1 ]
机构
[1] NR Elect Co Ltd, Res Inst, Nanjing, Jiangsu, Peoples R China
关键词
thermal power plant; electrical control and management system; digital technology; IEC61850;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As an integrated control system of the whole boiler-turbine and its electrical system, the Distributed Control System (DCS) has been widely used in thermal power plants. However, due to the large amount of microprocessor-based protection and monitoring devices in the auxiliary power system, some operation information in the devices can not be detected by the DCS. The devices provides a large number of the protection action Sequence of Events(SOE), measurement, alarm, fault wave record function and so on. To handle the problem, the Electrical Control and Management System(ECMS) which integrates all the electrical devices is widely used in China. The system can achieve the functions such as SOE information collection, measurement, power supply unit control, fault wave recording, auxiliary power consumption rate analysis, energy management, etc., bringing conveniences for the operation and maintenance of power plants. The paper introduces the scheme of ECMS based on IEC61850 for thermal power plants in details, including the ECMS that includes only auxiliary power system of power plant and the integrated ECMS includes the entire electrical system of power plant. For the step-up substation of power plant, primary equipment is placed far away from protection and control devices and bay control units. Using electronic CTs/VTs and intelligent control units can save the amount of cables on site, reduce substation occupied area and solve the insulation, saturation and resonance problems caused by conventional transformers. For the auxiliary power system of plants, protection, control and monitoring devices are installed in the switchgear cabinet that are close to primary equipment. Compared with electronic CTs/VTs, conventional CTs/VTs have more competitive price. Therefore the auxiliary power system inside plants adopts analog sampling method. Protection relay, control and monitoring devices are communicated via GOOSE network to achieve protection functions that can not be implemented by normal auxiliary power relay devices, such as busbar protection, breaker failure protection, high speed transfer and interlocking functions. The interlocking functions realized by motor protection devices through GOOSE network can be standby or backup of Distributed Control System (DCS). So far, the ECMS schemes discussed in the paper have been applied to many large capacity generators and put into service successfully, including the digital ECMS based on IEC61850 for 1000MW generator units in thermal power plants, the integrated ECMS for 1000MW generator units, and motor interlocking functions based on GOOSE network for a 600MW power plant. With the promotion of the IEC61850 technology in thermal power plants, some new protection and control methods will be necessarily applied, and with the IEC61850 modeling of thermal equipment in the future, IEC61850 technology will get more applications in power plants.
引用
收藏
页码:198 / 202
页数:5
相关论文
共 50 条
  • [1] IEC61850 based modeling and implementation for management of electrical substation auxiliary system
    Zhou Di
    Wang Zizhan
    Zhong Youping
    [J]. ADVANCES IN MECHATRONICS, AUTOMATION AND APPLIED INFORMATION TECHNOLOGIES, PTS 1 AND 2, 2014, 846-847 : 1462 - 1467
  • [2] Control and automation of power system substation using IEC61850 communication
    Sidhu, TS
    Gangadharan, PK
    [J]. 2005 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS (CCA), VOLS 1AND 2, 2005, : 1331 - 1336
  • [3] Digital Control of the Substations Based on IEC61850
    Zhou, Honglei
    Ran, Xiaohong
    [J]. SMART MATERIALS AND INTELLIGENT SYSTEMS, PTS 1 AND 2, 2011, 143-144 : 1017 - 1021
  • [4] Research and Implementation for Power and Environment Monitoring System Based on IEC61850
    Liu, Hong
    Zhang, Jianqiang
    Wang, Shuai
    Meng, Xiangyan
    [J]. 2017 IEEE 3RD INFORMATION TECHNOLOGY AND MECHATRONICS ENGINEERING CONFERENCE (ITOEC), 2017, : 1067 - 1071
  • [5] IEC61850 based Substation Automation System
    Kaneda, Keiichi
    Tamura, Setsuo
    Fujiyama, Nobuhisa
    Arata, Yoshikazu
    Ito, Hachidai
    [J]. 2008 JOINT INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON) AND IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2008, : 1420 - 1427
  • [6] Application of IEC61850 in Energy Management System for Microgrids
    Mao, Meiqin
    Mei, Fengming
    Jin, Peng
    Chang, Liuchen
    [J]. 2014 IEEE 5TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG), 2014,
  • [7] Prognostics Health Management System for Power Transformer with IEC61850 and Internet of Things
    Elmashtoly, Ahmed Mohamed
    Chang, Choong-Koo
    [J]. JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2020, 15 (02) : 673 - 683
  • [8] Prognostics Health Management System for Power Transformer with IEC61850 and Internet of Things
    Ahmed Mohamed Elmashtoly
    Choong-Koo Chang
    [J]. Journal of Electrical Engineering & Technology, 2020, 15 : 673 - 683
  • [9] Study on Electrical Digital Simulation System Following IEC61850
    Gao Guangling
    Pan Zhencun
    Gao Houlei
    Gao Zhanjun
    Cong Wei
    Pan Xianghua
    [J]. 2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 2023 - +
  • [10] IEC61850 Standards-Based System of Remote
    Chao, Li-Meng
    Hua, Wang-Su
    Xin, Zhou
    [J]. 2011 INTERNATIONAL CONFERENCE ON MACHINE INTELLIGENCE (ICMI 2011), PT 2, 2011, 4 : 216 - 223