Haemodialysis with on-line monitoring equipment:: tools or toys?

被引:81
|
作者
Locatelli, F
Buoncristiani, U
Canaud, B
Köhler, H
Petitclerc, T
Zucchelli, P
机构
[1] Osped A Manzoni, Div Nephrol & Dialysis, I-23900 Lecce, Italy
[2] Univ Perugia, Nephrol & Dialysis Unit, I-06100 Perugia, Italy
[3] M Malpighi Hosp, Dept Nephrol & Dialysis, Bologna, Italy
[4] CHU Montpellier, Lapeyronie Univ Hosp, Dept Nephrol, Montpellier, France
[5] AURA, Ctr Rntrainement Hemodialyse Domicile, Paris, France
[6] Univ Saarlandes Kliniken, Schwerpunkt Nephrol, Homburg, Germany
关键词
bio-feedback; blood volume monitoring; blood volume control; conductivity; dialysis dose; haemodialysis; hypotension; ionic dialysance; on-line monitoring; sodium balance; thermal energy balance; urea monitors; vascular access monitoring;
D O I
10.1093/ndt/gfh555
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. On-line monitoring of chemical/physical signals during haemodialysis (HD) and bio-feedback represents the first step towards a 'physiological' HD system incorporating adaptive and logic controls in order to achieve pre-set treatment targets. Methods. Discussions took place to achieve a consensus on key points relating to on-line monitoring and bio-feedback, focusing on the clinical applications. Results. The relative blood volume (BV) reduction during HD can be monitored by optic devices detecting the variations in concentration of haemoglobin/ haematocrit. BV changes result from an equilibrium between ultrafiltration and the refilling capacity. However, BV reduction has little power in predicting intra-HD hypotensive episodes, while the combination of the patient-dialysate sodium gradient, the relative BV reduction between the 20th and 40th minute of HD, the irregularity of the profile of BV reduction over time and the heart rate decrease from the start to the 20th minute of HD predict intra-HD hypotension with a sensitivity of 82%, a specificity of 73% and an accuracy of 80%. A biofeedback system drives the relative BV reduction according to desired values by instantaneously changing the ultrafiltration rate and the dialysate conductivity. This system has proved to reduce the incidence of intra-HD hypotension episodes significantly. Ionic dialysance and the patient's plasma conductivity can be calculated easily from on-line inlet and outlet dialysate conductivity measurements at two different steps of dialysate conductivity. Ionic dialysance is equivalent to urea clearance corrected for recirculation and is a tool for continuously monitoring the dialysis efficiency and detecting early problems with the delivery of the prescribed dose of dialysis. Given the strict and linear relationship between conductivity and sodium content, the conductivity values replace the sodium concentration values and this permits the development of a conductivity kinetic model, by means of which sodium balance can be achieved at each dialysis session. The conductivity kinetic model has been demonstrated to improve intra-HD cardiovascular stability in hypotension-prone patients significantly. Ionic dialysance is also a useful tool to monitor vascular access function, as it can be used to obtain serial measurements of vascular access blood flow. On-line urea monitors provide detailed information on intra-HD urea kinetics and delivered dialysis dose, but they are not in widespread use because of the costs related to the disposable materials (e.g. urease cartridge). The body temperature monitor measures the blood temperature at the arterial and venous lines of the extra-corporeal circuit and, thanks to a bio-feedback system, is able to modulate the dialysate temperature in order to influence the patient's core body temperature, which can be kept at constant values. This is associated with improved intra-HD cardiovascular stability. The module can also be used to quantify total recirculation. Conclusions. On-line monitoring devices and biofeedback systems have evolved from toys for research use to tools for routine clinical application.. particularly in patients with clinical complications. Conductivity monitoring appears the most versatile tool, as it permits quantification of delivered dialysis dose, achievement of sodium balance and surveillance of vascular access function, potentially at each dialysis session and without extra cost. Haemodialysis with on-line monitoring equipment: tools or toys?.
引用
收藏
页码:22 / 33
页数:12
相关论文
共 50 条
  • [1] An On-line Monitoring System for Navigation Equipment
    Wang, Bo
    Yang, Ping
    Liu, Jing
    Yang, Zhengbo
    Liang, Fei
    [J]. 2ND INTERNATIONAL CONFERENCE ON MATERIALS SCIENCE, RESOURCE AND ENVIRONMENTAL ENGINEERING (MSREE 2017), 2017, 1890
  • [2] On-line Monitoring System Design of Electrical Equipment
    Zheng, Chenxi
    Zhao, Dong
    [J]. PROCEEDINGS OF THE 2016 2ND WORKSHOP ON ADVANCED RESEARCH AND TECHNOLOGY IN INDUSTRY APPLICATIONS, 2016, 81 : 544 - 547
  • [3] On-line temperature monitoring of power distribution equipment
    Livshitz, A
    Bukengolts, B
    Chudnovsky, BH
    Chudnovsky, BA
    [J]. Industry Applications Society 52nd Annual Petroleum and Chemical Industry Conference, 2005, : 223 - 231
  • [4] Overview: on-line monitoring for electrical equipment in substation
    Zhang, Y.L.
    Wang, W.S.
    Xu, D.K.
    [J]. Gaoya Dianqi/High Voltage Apparatus, 2001, 37 (05):
  • [5] Development of On-line Monitoring System for Automation Equipment
    Wang, Xiaowei
    Yang, Libo
    Hu, Wenping
    Wang, Yajun
    Hu, Cong
    Li Xuanyi
    [J]. 2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 1068 - 1073
  • [6] On-line monitoring of the intravascular volume during haemodialysis by continuous refractometry
    Kuhlmann, U
    Buuren, FV
    Aziz, O
    Lange, H
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1999, 22 (04): : 205 - 209
  • [7] Industrial implementation of on-line performance monitoring tools
    Hägglund, T
    [J]. CONTROL ENGINEERING PRACTICE, 2005, 13 (11) : 1383 - 1390
  • [8] On-line condition monitoring and diagnostics of power distribution equipment
    Livshitz, A
    Chudnovsky, BH
    Bukengolts, B
    [J]. 2004 IEEE PES POWER SYSTEMS CONFERENCE & EXPOSITION, VOLS 1 - 3, 2004, : 646 - 653
  • [9] Developing Capacitive Equipment On-Line Monitoring Intelligence Software
    Zhang, Weicong
    Yang, Lichun
    [J]. FOURTH INTERNATIONAL CONFERENCE ON MACHINE VISION (ICMV 2011): MACHINE VISION, IMAGE PROCESSING, AND PATTERN ANALYSIS, 2012, 8349
  • [10] Development of on-line monitoring equipment of medium voltage switchgear
    Huang Xiping
    Wang Xin
    Qiang Wen
    [J]. ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL III, 2007, : 388 - +