SERIAL NONRIGID VASCULAR REGISTRATION USING WEIGHTED NORMALIZED MUTUAL INFORMATION

被引:6
|
作者
Suh, J. W. [1 ]
Scheinost, D.
Qian, X. [5 ]
Sinusas, A. J. [2 ]
Breuer, C. K. [3 ]
Papademetris, X. [4 ]
机构
[1] Yale Univ, Dept Diagnost Radiol, New Haven, CT 06520 USA
[2] Yale Univ, Dept Internal Med, New Haven, CT 06520 USA
[3] Yale Univ, Dept Surg, New Haven, CT 06520 USA
[4] Yale Univ, Biomed Engn, New Haven, CT 06520 USA
[5] Univ S Florida, Dept Comp Sci & Engn, Tampa, FL 33620 USA
关键词
vascular registration; weighted mutual information; HIERARCHICAL APPROACH; IMAGES; MOTION; MODELS;
D O I
10.1109/ISBI.2010.5490422
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Vascular registration is a challenging problem with many potential applications. However, registering vessels accurately is difficult as they often occupy a small portion of the image and their relative motion/deformation is swamped by the displacements seen in large organs such as the heart and the liver. Our registration method uses a vessel detection algorithm to generate a vesselness image (probability of having a vessel at any given voxel) which is used to construct a weighting factor that is used to modify the intensity metric to give preference to vascular structures while maintaining the larger context. Therefore, our proposing method uses fully data-driven calculated weights and needs no prior knowledge for the weight calculation. We applied our method to the registration of serial MRI lamb images obtained from studies on tissue engineered vascular grafts and demonstrate encouraging performance as compared to non-weighted registration methods.
引用
收藏
页码:25 / 28
页数:4
相关论文
共 50 条
  • [1] Nonrigid Image Registration of Brain MR Images Using Normalized Mutual Information
    Pradhan, Smita
    Patra, Dipti
    [J]. PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON SOFT COMPUTING FOR PROBLEM SOLVING (SOCPROS 2012), 2014, 236 : 1069 - 1077
  • [2] Nonrigid mammogram registration using mutual information
    Wirth, MA
    Narhan, J
    Gray, D
    [J]. MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 562 - 573
  • [3] Nonrigid Image Registration Using Conditional Mutual Information
    Loeckx, Dirk
    Slagmolen, Pieter
    Maes, Frederik
    Vandermeulen, Dirk
    Suetens, Paul
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (01) : 19 - 29
  • [4] Nonrigid image registration using conditional mutual information
    Loeckx, Dirk
    Slagmolen, Pieter
    Maes, Frederik
    Vandermeulen, Dirk
    Suetens, Paul
    [J]. INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 2007, 4584 : 725 - +
  • [5] A model for nonrigid mammogram registration using mutual information
    Wirth, MA
    Narhan, J
    Gray, D
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 243 - 245
  • [6] Spatial Information Encoded Mutual Information for Nonrigid Registration
    Zhuang, Xiahai
    Hawkes, David J.
    Ourselin, Sebastien
    [J]. BIOMEDICAL IMAGE REGISTRATION, 2010, 6204 : 246 - 257
  • [7] Nonrigid registration of medical image based on adaptive local structure tensor and normalized mutual information
    Yang, Tiejun
    Tang, Qi
    Li, Lei
    Song, Jikun
    Zhu, Chunhua
    Tang, Lu
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (06): : 99 - 110
  • [8] Self-similarity weighted mutual information: A new nonrigid image registration metric
    Rivaz, Hassan
    Karimaghaloo, Zahra
    Collins, D. Louis
    [J]. MEDICAL IMAGE ANALYSIS, 2014, 18 (02) : 343 - 358
  • [9] Self-similarity Weighted Mutual Information: A New Nonrigid Image Registration Metric
    Rivaz, Hassan
    Collins, D. Louis
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2012, PT III, 2012, 7512 : 91 - 98
  • [10] Efficient Acceleration of Mutual Information Computation for Nonrigid Registration Using CUDA
    Ikeda, Kei
    Ino, Fumihiko
    Hagihara, Kenichi
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2014, 18 (03) : 956 - 968