The MLC tongue-and-groove effect on IMRT dose distributions

被引:0
|
作者
Deng, J [1 ]
Pawlicki, T [1 ]
Chen, Y [1 ]
Li, JS [1 ]
Jiang, SB [1 ]
Ma, CM [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Sch Med, Stanford, CA 94305 USA
关键词
MLC; tongue-and-groove effect; EGS4 Monte Carlo; IMRT;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have investigated the tongue-and-groove effect on the IMRT dose distributions using the EGS4/MCDOSE Monte Carlo code. We have compared the dose distributions computed by MCDOSE using the fluence maps with and without tongue-and-groove effect. Our results showed that, for one intensity modulated treatment field, the tongue-and-groove effect could be seen clearly in the dose distributions. For an IMRT treatment with multiple gantry angles, the! difference between the dose distributions with and without the tongue-and-groove effect was reduced significantly. After considering the setup errors, however, no distinguished discrepancies were found, indicating that, for IMRT treatment planning, the tongue-and-groove effect can be neglected due to its negligible Impact on the overall dose distributions.
引用
收藏
页码:2075 / 2078
页数:4
相关论文
共 50 条
  • [1] The MLC tongue-and-groove effect on IMRT dose distributions
    Deng, J
    Pawlicki, T
    Chen, Y
    Li, JS
    Jiang, SB
    Ma, CM
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04): : 1039 - 1060
  • [2] A general analysis of the ''tongue-and-groove'' effect in dynamic MLC therapy
    Webb, S
    Convery, DJ
    Bortfeld, T
    Stein, J
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 342 - 345
  • [3] A Quantitative Approach of Tongue-And-Groove Effect for the Varian 120 MLC
    Kim, H.
    Ye, S.
    Kim, J.
    Park, J.
    Park, Y.
    Kim, S.
    MEDICAL PHYSICS, 2011, 38 (06) : 3653 - U19
  • [4] A new MLC segmentation algorithm for step-and-shoot IMRT without tongue-and-groove error
    Luan, S
    Wang, C
    Chen, D
    Hu, X
    Naqvi, S
    Yu, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1843 - 1843
  • [5] Reducing leaf travel distance and tongue-and-groove effect for segmental IMRT
    Dai, J
    Que, W
    MEDICAL PHYSICS, 2004, 31 (06) : 1914 - 1914
  • [6] An improved MLC segmentation algorithm and software for step-and-shoot IMRT delivery without tongue-and-groove error
    Luan, Shuang
    Wang, Chao
    Chen, Danny Z.
    Hu, Xiaobo S.
    Naqvi, Shahid A.
    Wu, Xingen
    Yu, Cedric X.
    MEDICAL PHYSICS, 2006, 33 (05) : 1199 - 1212
  • [7] Gap-stepped MLC leaves with filler blades can eliminate tongue-and-groove underdoses when delivering IMRT with maximum efficiency
    Symonds-Tayler, JRN
    Webb, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08): : 2393 - 2395
  • [8] A generalized MLC segmentation algorithm for step-and-shoot BIRT with no tongue-and-groove error
    Wang, C
    Luan, S
    Chen, DZ
    Hu, X
    Yu, C
    MEDICAL PHYSICS, 2005, 32 (06) : 1972 - 1972
  • [9] Incorporating the Tongue-And-Groove Effect in Direct Aperture Optimization
    Salari, E.
    Romeijn, E.
    Men, C.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [10] Impact of Tongue-And-Groove Width On MLC-Defined Small Field Dosimetry for Pinnacle 9.0
    Jang, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3830 - 3830