Assessment of root caries under wet and dry conditions using swept-source optical coherence tomography (SS-OCT)

被引:8
|
作者
Zhou, Yuan [1 ]
Shimada, Yasushi [1 ,2 ]
Matin, Khairul [1 ,3 ]
Sadr, Alireza [4 ]
Yoshiyama, Masahiro [2 ]
Sumi, Yasunori [5 ]
Tagami, Junji [1 ]
机构
[1] Tokyo Med & Dent Univ, Cariol & Operat Dent, Grad Sch Med & Dent Sci, Bunkyo Ku, 1-5-45 Yushima, Tokyo 1138549, Japan
[2] Okayama Univ, Dept Operat Dent, Grad Sch Med Dent & Pharmaceut Sci, Kita Ku, 2-5-1 Shikata Cho, Okayama 7008525, Japan
[3] Tsurumi Univ, Endowed Dept Int Oral Hlth Sci, Dept Translat Res, Sch Dent Med,Tsurumi Ku, 2-1-3 Tsurumi, Yokohama, Kanagawa 2308501, Japan
[4] Univ Washington, Biomimet Biomat Biophoton Biomech & Technol Lab, Dept Restorat Dent, 1959 NE Pacific St Box 357456, Seattle, WA 98195 USA
[5] Natl Hosp Geriatr Med, Div Oral & Dent Surg, Dept Adv Med, Natl Ctr Geriatr & Gerontol, 36-3 Gengo,Morioka Cho, Obu, Aichi 4748511, Japan
基金
日本学术振兴会;
关键词
Root caries; Optical coherence tomography; Biofilms; Streptococcus mutans; COLLAGEN DEGRADATION; DIMENSIONAL CHANGES; HUMAN DENTIN; DEMINERALIZATION; ENAMEL; HYDRATION; MATRIX; MODEL;
D O I
10.4012/dmj.2017-273
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to compare optical properties of root caries under two observing conditions using swept-source optical coherence tomography (SS-OCT). In vitro and natural root caries were observed by SS-OCT under wet and dry conditions, followed by confocal laser scanning microscope (CLSM) and transverse microradiography (TMR). Signal intensity (SI), distance between SI peaks (SI-distance) and optical lesion depth were obtained from OCT. Lesion depth was measured from CLSM; lesion depth (LDTMR) and mineral loss (ML) were obtained from TMR. In vitro root caries under wet and dry conditions showed different OCT images and SI patterns. Lesion depth of OCT and that of CLSM, SI-distance and LDTMR, LD(TMR)( )and ML significantly correlated. Under dry conditions, half natural root caries showed similar OCT images and SI patterns as in vitro root caries. The base of demineralized dentin could be detected more clearly under dry conditions than under wet conditions.
引用
收藏
页码:880 / 888
页数:9
相关论文
共 50 条
  • [1] Validation of swept-source optical coherence tomography (SS-OCT) for the diagnosis of occlusal caries
    Shimada, Yasushi
    Sadr, Alireza
    Burrow, Michael F.
    Tagami, Junji
    Ozawa, Nobuyoshi
    Sumi, Yasunori
    [J]. JOURNAL OF DENTISTRY, 2010, 38 (08) : 655 - 665
  • [2] Detection of Root Surface Fractures with Swept-Source Optical Coherence Tomography (SS-OCT)
    Yoshioka, Toshihiko
    Sakaue, Hitoshi
    Ishimura, Hitomi
    Ebihara, Arata
    Suda, Hideaki
    Sumi, Yasunori
    [J]. PHOTOMEDICINE AND LASER SURGERY, 2013, 31 (01) : 23 - 27
  • [3] Assessment of bacterial demineralization around composite restorations using swept-source optical coherence tomography (SS-OCT)
    Zhou, Yuan
    Shimada, Yasushi
    Matin, Khairul
    Sadr, Alireza
    Sumi, Yasunori
    Tagami, Junji
    [J]. DENTAL MATERIALS, 2016, 32 (09) : 1177 - 1188
  • [4] The impact of swept-source optical coherence tomography (SS-OCT) in the management of scleral inflammation
    Sainz De La Maza, Maite
    Hereu, Mireia
    Hernandez, Monica
    Mesquida, Marina
    Llorenc, Victor
    Sala-Puigdollers, Anna
    Matas, Jessica
    Molins, Blanca
    Adan Civera, Alfredo
    Zarranz-Ventura, Iavier
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [5] Noninvasive cross-sectional imaging of proximal caries using swept-source optical coherence tomography (SS-OCT) in vivo
    Shimada, Yasushi
    Nakagawa, Hisaichi
    Sadr, Alireza
    Wada, Ikumi
    Nakajima, Masatoshi
    Nikaido, Toru
    Otsuki, Masayuki
    Tagami, Junji
    Sumi, Yasunori
    [J]. JOURNAL OF BIOPHOTONICS, 2014, 7 (07) : 506 - 513
  • [6] Swept-source optical coherence tomography (SS-OCT) biomarkers for progression of suspicious choroidal lesions
    Munsell, Mary
    Lains, Ines
    Zeng, Rebecca
    Miller, John
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [7] Analysis of Lens Thickness Distribution Based on Swept-Source Optical Coherence Tomography (SS-OCT)
    Feng, Xi
    Wang, Yong
    Liang, Jianheng
    Xu, Yali
    Ortega-Usobiaga, Julio
    Cao, Danmin
    [J]. JOURNAL OF OPHTHALMOLOGY, 2021, 2021
  • [8] Validation of swept source optical coherence tomography (SS-OCT) for the diagnosis of smooth surface caries in vitro
    Nakagawa, Hisaichi
    Sadr, Alireza
    Shimada, Yasushi
    Tagami, Junji
    Sumi, Yasunori
    [J]. JOURNAL OF DENTISTRY, 2013, 41 (01) : 80 - 89
  • [9] Assessment of defects at tooth/self-adhering flowable composite interface using swept-source optical coherence tomography (SS-OCT)
    Park, Kyung-Jin
    Schneider, Hartmut
    Haak, Rainer
    [J]. DENTAL MATERIALS, 2015, 31 (05) : 534 - 541
  • [10] Assessment of Open-Angle Glaucoma Peripapillary and Macular Choroidal Thickness Using Swept-Source Optical Coherence Tomography (SS-OCT)
    Song, Yong Ju
    Kim, Young Kook
    Jeoung, Jin Wook
    Park, Ki Ho
    [J]. PLOS ONE, 2016, 11 (06):