Direct frequency domain fluorescence lifetime imaging using field programmable gate arrays for real time processing

被引:10
|
作者
Serafino, Michael J. [1 ,2 ]
Applegate, Brian E. [1 ,3 ]
Jo, Javier A. [1 ,2 ]
机构
[1] Texas A&M Univ, Dept Biomed Engn, Emerging Technol Bldg,3120 TAMU, College Stn, TX 77843 USA
[2] Univ Oklahoma, Dept Elect & Comp Engn, Stephenson Res & Technol Ctr, Suite 1108,101 Davild L Boren Blvd, Norman, OK 73072 USA
[3] Univ Southern Calif, Caruso Dept Otolaryngol Head & Neck Surg, 1501 San Pablo St, Los Angeles, CA 90033 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2020年 / 91卷 / 03期
关键词
ATHEROSCLEROTIC PLAQUES; PHASE; CALIBRATION; DEPENDENCE; SYSTEM; COST;
D O I
10.1063/1.5127297
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Frequency domain (FD) fluorescence lifetime imaging (FLIM) involves the excitation of the sample of interest with a modulated light source and digitization of the fluorescence emission for further analysis. Traditional FD-FLIM systems use heterodyne or homodyne detection, where the excitation light source and detector are modulated at specific frequency(s). More recently, FD-FLIM systems that use reflection of the light source as a trigger or phase reference for lifetime calculations have been developed. These detection schemes, however, require extra components that increase the cost and complexity of the FD-FLIM system. Here, we report a novel FD-FLIM detection scheme whereby the light source modulation and emission digitization are implemented using Field Programmable Gate Arrays (FPGAs), and fixed gain avalanche photodiodes are used for fluorescence detection. The reported FD-FLIM system was designed for probing nanosecond lifetime fluorophores (2-10 ns) at three emission bands simultaneously. The system utilizes a 375 nm diode laser for excitation at multiple simultaneous modulation frequencies (between 1 MHz and 83 MHz, bandwidth limited intentionally by using a lowpass filter) and three fixed gain avalanche photodiodes for simultaneous detection of three emission bands: 405/20 nm, 440/40 nm, and 525/50 nm (center/FWHM). Real-time computation of the modulation and phase lifetimes is simply performed by direct application of the discrete Fourier transform (max. of 10 frequencies) to the digitized fluorescence emission signals. The accuracy and sensitivity of this novel FD-FLIM detection scheme was demonstrated by imaging standard fluorophores and ex vivo unfixed human coronary artery tissue samples.
引用
收藏
页数:15
相关论文
共 50 条
  • [2] Optimized implementation of real-time image processing algorithms on field programmable gate arrays
    Dias, AF
    Lavarenne, C
    Akil, M
    Sorel, Y
    [J]. ICSP '98: 1998 FOURTH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, PROCEEDINGS, VOLS I AND II, 1998, : 1080 - 1083
  • [3] Real-time processing for Fourier domain optical coherence tomography using a field programmable gate array
    Ustun, Teoman E.
    Iftimia, Nicusor V.
    Ferguson, R. Daniel
    Hammer, Daniel X.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (11):
  • [4] Real-time sound localization using field-programmable gate arrays
    Nguyen, D
    Aarabi, P
    Sheikholeslami, A
    [J]. 2003 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOL II, PROCEEDINGS: SPEECH II; INDUSTRY TECHNOLOGY TRACKS; DESIGN & IMPLEMENTATION OF SIGNAL PROCESSING SYSTEMS; NEURAL NETWORKS FOR SIGNAL PROCESSING, 2003, : 573 - 576
  • [5] Real-time sound localization using field-programmable gate arrays
    Nguyen, D
    Aarabi, P
    Sheikholeslami, A
    [J]. 2003 INTERNATIONAL CONFERENCE ON MULTIMEDIA AND EXPO, VOL II, PROCEEDINGS, 2003, : 829 - 832
  • [6] Reconfigurable processing with field programmable gate arrays
    Fawcett, BK
    Watson, J
    [J]. INTERNATIONAL CONFERENCE ON APPLICATION-SPECIFIC SYSTEMS, ARCHITECTURES AND PROCESSORS 1996, PROCEEDINGS, 1996, : 293 - 302
  • [7] Image Processing on Field Programmable Gate Arrays
    Celik, Ali Recai
    [J]. 2015 23RD SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2015, : 1501 - 1504
  • [8] Direct frequency domain fluorescence lifetime imaging using simultaneous ultraviolet and visible excitation
    Erafino, Michael J. S.
    Jo, Avier A.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2023, 14 (04) : 1608 - 1625
  • [9] Potential of Real-Time Cylinder Pressure Analysis by Using Field Programmable Gate Arrays
    Jan Pfluger
    Rene Savelsberg
    Thomas Hülshorst
    Stefan Pischinger
    Jakob Andert
    [J]. International Journal of Automotive Technology, 2018, 19 : 643 - 650
  • [10] Potential of Real-Time Cylinder Pressure Analysis by Using Field Programmable Gate Arrays
    Pfluger, Jan
    Savelsberg, Rene
    Huelshorst, Thomas
    Pischinger, Stefan
    Andert, Jakob
    [J]. INTERNATIONAL JOURNAL OF AUTOMOTIVE TECHNOLOGY, 2018, 19 (04) : 643 - 650